Hikvision DS-K1T671TM-3XF Face Recognition Terminal

Quick Start Guide

1. Appearance

The Hikvision DS-K1T671TM-3XF Face Recognition Terminal features a modern design with key components for access control and temperature measurement. Its dimensions are approximately 282.81 mm in height, 116.5 mm in width, and 36.7 mm in depth.

Visible components include:

  • Touch Screen
  • Card Presenting Area
  • Camera
  • IR Light (x2)
  • Thermographic Module (x2)
  • TAMPER switch
  • USB Interface
  • Network Interface
  • Wiring Terminal
  • Debugging Port (reserved for debugging)
  • Power Interface
  • PSAM Card Slot (reserved)

2. Installation

Installation Environment

For optimal performance, the device should be installed in an indoor, windless environment. Key environmental considerations include:

  • Illumination: Ensure the environment illumination is more than 100 Lux.
  • Placement: Position the device at least 2 meters away from direct light sources and at least 3 meters away from windows. Avoid direct sunlight, strong backlighting, or being too close to light sources, as these can affect facial recognition accuracy.

Installation Steps

Follow these steps for mounting the device:

  1. Drill holes on the wall or surface and install a gang box if required.
  2. Secure the mounting plate to the gang box or wall using the supplied screws (e.g., 4x KA4×22-SUS).
  3. Route the cables through the cable hole of the mounting plate and connect them to the corresponding external devices.
  4. Align the device with the mounting plate and hang the terminal. Ensure the mounting sheets on the sides of the plate fit into the device's back holes.
  5. Secure the device to the mounting plate using the supplied M4 screws. The device is secured when the screw heads are beneath the device surface.

The installation height is recommended but can be adjusted based on specific needs. The device can also be mounted directly on a wall or other surfaces without a gang box; refer to the user manual for details. A mounting template is provided for accurate hole drilling.

3.1 Device Wiring (Normal)

This section details the standard wiring connections for the terminal.

  • Network Interface: Connect to the network for communication.
  • Door Contact: Connect to a door magnetic sensor.
  • BTN (Exit Button): Connect to an exit button.
  • Wiring Terminal: Provides connections for door lock control (NC, COM, NO terminals) and other peripherals.

Important Wiring Notes:

  • Ensure a common ground connection between the device, RS-485 card reader, door magnetic sensor, and exit button when used together.
  • The Wiegand terminal is typically configured as input. For connection to an access controller, the Wiegand direction may need to be set to "Output" as per the user manual.
  • Suggested external power supply for door locks: 12 V, 1A.
  • Suggested external power supply for Wiegand card readers: 12 V, 1A.
  • Never wire the device directly to the electric supply.

A QR code is provided to access the full user manual for detailed information.

Approved Power Supplies

Use only power supplies listed below:

ModelManufacturerStandard
C2000IC12.0-24P-DEMOSO Power Supply Technology Co., Ltd.PG
C2000IC12.0-24P-GBMOSO Power Supply Technology Co., Ltd.PB
ADS-24S-12 1224GPGShenzhen Honor Electronic Co., Ltd.PG

3.2 Device Wiring (With Secure Door Control Unit)

This section outlines the wiring for integrating the Face Recognition Terminal with a Secure Door Control Unit for enhanced security.

Connections:

  • Face Recognition Terminal connects to the Secure Door Control Unit.
  • The Secure Door Control Unit has terminals for:
    • Power Input
    • Sensor Input (connects to Door Contact)
    • Exit Button Input (connects to Exit Button)
    • Lock Output (NC, COM, NO terminals, connects to Electric Dropbolt or Electric Strike)

Specific wire colors (Red, Black, Green/Brown, etc.) are shown connecting these units. The Secure Door Control Unit requires a separate external power supply, with 12 V, 0.5 A suggested.

4. Activation

After installation and connecting the network cable, the device must be activated before first use. Upon powering on, if the device is not activated, it will automatically enter the Activate Device page.

Activation Steps:

  1. Create a strong password and confirm it.
  2. Tap "Activate" to complete the process.

Password Recommendation:

Hikvision strongly recommends creating a strong password (minimum 8 characters, including uppercase letters, lowercase letters, numbers, and special characters) to enhance product security. Regular password resets, especially in high-security systems (monthly or weekly), are advised.

5. Temperature Measurement Settings

Access the "Temperature" option from the main page to configure temperature measurement parameters:

  • Enable Temperature Detection: Toggle to enable or disable temperature measurement alongside user authentication. When disabled, only authentication occurs.
  • Over-Temperature Alarm Threshold: Set a threshold (default 37.3°C). An alarm is triggered if the detected temperature exceeds this value.
  • Door Not Open When Detecting Abnormal Temperature: When enabled, the door will remain locked if the detected temperature is higher than the configured threshold.
  • Temperature Measurement Only: Toggle to enable temperature measurement without user authentication. When disabled, both authentication and temperature measurement occur.
  • Measurement Area Calibration/Settings: Configure the specific area for temperature measurement and adjust correction parameters.
  • Black Body Settings: If using a black body for calibration, configure its parameters such as distance, temperature, and emissivity.

6. Adding Face Information

To add user face information:

  1. Verify your identity on the screen to access the main page.
  2. Navigate to the User Management page, tap the '+' icon, and select 'Face' to enter the Add User page.
  3. Set user parameters as needed.
  4. Tap 'Face' and follow the on-screen instructions to capture the face information. The captured picture can be viewed in the upper right corner of the page. Ensure the face picture is of good quality and appropriate size.
  5. Tap to save the settings.

After saving, return to the initial page to start authentication. For other authentication methods, consult the device user manual. If the device is affected by light or other factors, consider using alternative authentication methods.

Tips When Collecting/Comparing Face Picture

Expression

Maintain a natural expression, similar to the example image. Avoid wearing hats, sunglasses, or accessories that may interfere with facial recognition. Ensure hair does not cover the eyes or ears, and avoid heavy makeup.

Posture

For accurate face capture, position your face looking directly at the camera. Avoid tilting, turning sideways, raising, or bowing your head.

Size

Ensure your face is centered within the collecting window. Avoid being too close or too far from the device.

Positions When Collecting/Comparing Face Picture

Recommended Distance: 0.5 meters.

Recommended Height: 1.43 meters to 1.90 meters.

Visual guides illustrate correct and incorrect positioning, including height (Too High, Too Low) and distance (Too Close, Too Far).

Note: Biometric recognition products are not 100% effective against spoofing. For higher security, use multiple authentication modes.

Regulatory Information

FCC Compliance

This device complies with Part 15 of the FCC Rules. Operation is subject to two conditions: it must not cause harmful interference, and it must accept any interference received. This equipment has been tested and found to comply with the limits for a Class B digital device, designed to provide reasonable protection against harmful interference in residential installations. A minimum distance of 20cm between the radiator and your body is required during operation.

CE Marking

The product is marked with "CE" and complies with applicable harmonized European standards under the RE Directive 2014/53/EU, the EMC Directive 2014/30/EU, and the RoHS Directive 2011/65/EU.

WEEE Directive (2012/19/EU)

Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier or dispose of it at designated collection points. More information is available at www.recyclethis.info.

Battery Directive (2006/66/EC)

This product contains a battery that cannot be disposed of as unsorted municipal waste. The battery is marked with a symbol, potentially including indicators for cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return the battery to your supplier or a designated collection point. More information is available at www.recyclethis.info.

Industry Canada Compliance

This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation.

Safety Instructions

These instructions ensure correct product usage and prevent danger or property loss. They are divided into Warnings and Cautions.

Warnings

  • All electronic operations must strictly comply with electrical safety regulations, fire prevention regulations, and other local regulations.
  • Use only power adapters provided by reputable companies, ensuring the power consumption meets the required value.
  • Do not connect multiple devices to a single power adapter to prevent overload, overheating, or fire hazards.
  • Always disconnect power before wiring, installing, or dismantling the device.
  • Ensure the product is firmly fixed when installed on a wall or ceiling.
  • If smoke, odors, or unusual noise emanates from the device, immediately turn off the power, unplug the cable, and contact the service center.
  • Never attempt to disassemble the device yourself; unauthorized repairs are not covered.

Cautions

  • Avoid dropping the device, subjecting it to physical shock, or exposing it to high electromagnetic radiation. Do not install on vibrating surfaces.
  • Do not place the device in extremely hot, cold, dusty, or damp locations, or expose it to high electromagnetic radiation.
  • Keep device covers for indoor use protected from rain and moisture.
  • Avoid exposing the equipment to direct sunlight, low ventilation, or heat sources like heaters or radiators.
  • Do not aim the device at the sun or excessively bright places, as this may cause blooming or smearing and affect sensor endurance.
  • Use the provided glove when opening the device cover to avoid finger sweat potentially damaging the surface coating.
  • Clean inside and outside surfaces with a soft, dry cloth; avoid alkaline detergents.
  • Keep all wrappers after unpacking for future use, as they are needed for returns or repairs.
  • Improper battery use or replacement can lead to explosion hazards; use only the same or equivalent type and dispose of batteries according to manufacturer instructions.
  • Biometric recognition products are not 100% effective against spoofing; use multiple authentication modes for higher security.
  • For indoor installations, maintain a distance of at least 2 meters from light sources and 3 meters from windows or doors.
  • Input voltage must meet SELV (Safety Extra Low Voltage) and Limited Power Source requirements (100~240 VAC or 12 VDC per IEC60950-1).
Models: Face Recognition Terminal

File Info : application/pdf, 2 Pages, 4.87MB

PDF preview unavailable. Download the PDF instead.

ds-k1t671tm-3xf quickstartguide

References

Adobe PDF library 15.00

Related Documents

Preview Hikvision DS-K1T671TM-3XF Face Recognition Terminal Quick Start Guide
This guide provides essential information for installing, activating, and using the Hikvision DS-K1T671TM-3XF Face Recognition Terminal, including setup, wiring, temperature measurement, and face data management.
Preview Hikvision DS-K1T342 Series Face Recognition Terminal Quick Start Guide
Concise guide for installing and operating the Hikvision DS-K1T342 Series Face Recognition Terminal, covering appearance, installation, wiring, quick operation, safety, and regulatory information.
Preview Hikvision DS-K1T343 Series Face Recognition Terminal User Manual
Comprehensive user manual for the Hikvision DS-K1T343 Series Face Recognition Terminal, detailing installation, operation, configuration, safety guidelines, and features for advanced access control and time attendance management.
Preview Hikvision DS-K1T341C Series Face Recognition Terminal Quick Start Guide
A quick start guide for the Hikvision DS-K1T341C Series Face Recognition Terminal, covering appearance, installation, wiring, activation, and face picture collection.
Preview Hikvision DS-K1T344MBFWX-E1 Face Recognition Terminal Specifications
Detailed specifications for the Hikvision DS-K1T344MBFWX-E1 Face Recognition Terminal, including features, capacity, authentication methods, and technical details.
Preview Hikvision DS-K1T805 Series Access Control Terminal Quick Start Guide
A concise guide to installing, wiring, activating, and operating the Hikvision DS-K1T805 Series Access Control Terminal. Covers appearance, connection diagrams, activation methods, login procedures, and important safety and regulatory information.
Preview Hikvision Fingerprint Access Control Terminal Quick Start Guide
A quick start guide for the Hikvision Fingerprint Access Control Terminal, covering appearance, installation, activation, device wiring, and configuration.
Preview Hikvision DS-K1T341CMW/CMFW Face Recognition Terminal Setup with Bosch Solution 6000
A guide detailing the setup process for the Hikvision DS-K1T341CMW/CMFW Face Recognition Terminal when integrated with the Bosch Solution 6000 access control panel, including required components and wiring information.