Waykar Home Dehumidifier JD025CE-80

USER MANUAL

Please read this manual carefully before using the product.

Visit: www.waykar.com

FOR CUSTOMERS

Thank you for purchasing a Waykar dehumidifier. Waykar is committed to developing powerful and easy-to-use products to bring more convenience to your life. We highly recommend keeping this user manual for future reference in case of unexpected problems.

This dehumidifier is perfect for reducing humidity in family bedrooms, bathrooms, basements, offices, storage rooms, and more. Waykar dehumidifiers reduce room humidity efficiently, creating a healthier and more comfortable environment for you and your family.

REQUESTING CUSTOMER SERVICE

If you encounter any problems with the product, please contact Waykar Customer Service at support@waykar.com with your Purchase Order ID. We will help you solve the problems as soon as possible.

BEFORE FIRST USE

To protect the product from any internal damages, please keep the product in the upright position throughout its journey. Please take out the product and leave it standing in the upright position for 24 HOURS before plugging it in.

[Diagram: Dehumidifier shown in an upright position with arrows indicating it should remain upright.]

FEATURES

Powerful Moisture Removal

With cutting-edge technology, the dehumidifier powerfully removes moisture from the air to reduce the room humidity level and keep the indoor air dry and comfortable.

Lightweight Portable Design

The dehumidifier is compact and lightweight. The casters at the bottom make it easy to move the machine from one room to another.

Low Temperature Operation with Automatic Defrost Function

After the compressor runs continuously for 10 minutes, it starts to detect the coil temperature. When the coil temperature is ≤-2°C(28.4°F) for more than 10 seconds, the compressor stops immediately, and the fan runs with high wind. After 3 minutes, when the coil temperature is detected to be ≥5°C(41°F) for more than 10 seconds, the anti-frost mode exits, and the compressor and fan return to normal. (If the anti-frost time exceeds 10 minutes, it will automatically exit).

During the anti-frost period, if the water tank is full, the fan will be turned off. After the water level is restored, the fan will resume forced high-wind operation.

Adjustable Humidistat

Allows you to set different humidity levels for different rooms.

Timer On / Off

Program the machine to turn on and off automatically.

Quiet Operation

The dehumidifier operates with a low noise level.

Energy Efficient

The power consumption of the machine is low.

SAFETY PRECAUTIONS

IMPORTANT NOTICE FOR FIRST USE

For your safety, please read the manual carefully and keep it for future reference. Please install and use this product according to the instructions in the manual.

Explanation of Symbols Displayed on the Unit

SymbolTypeDescription
[Warning]WARNINGThis symbol shows that this appliance uses a flammable refrigerant. If the flammable refrigerant is leaked and exposed to an external ignition source, there is a risk of fire. (French: Avertissement : risque d'incendie/matériaux inflammables)
[Caution]CAUTIONThis symbol shows that the operation manual should be read carefully.
[Caution]CAUTIONThis symbol shows that a service personnel should be handling this equipment with reference to the installation manual.
[Caution]CAUTIONThis symbol shows that information is available such as the operating manual or installation manual.

SPECIFICATIONS

MODELJD025CE-80
POWER SOURCE115V~60Hz
TOTAL INPUT CURRENT3.5A
MOISTURE REMOVAL (65°F, 60%RH)24.93 PINTS (11.79 L/DAY)
MOISTURE REMOVAL (80 °F, 60%RH)35 PINTS (16.56 L/DAY)
MOISTURE REMOVAL (86 °F, 80%RH)60 PINTS (28.38 L/DAY)
MOISTURE REMOVAL (95 °F, 90%RH)80 PINTS (37.84 L/DAY)
INPUT POWER (65°F, 60%RH)275W
INPUT CURRENT (65°F, 60%RH)2.6A
IEF (65°F, 60%RH)1.7 L/kWh
MOTOR FLA0.38 A
MOTOR COMPRESSOR(RLA/LRA)2.5A / 16.2A
REFRIGERANTR32/90g(3.18oz)
MAXIMUM ALLOWABLE PRESSURE3.72MPa(540psig)
HIGH PRESSURE2.07MPa(300psig)
LOW PRESSURE0.85MPa(123psig)

The dehumidification capacity is rated at a room temperature of 18.3°C(64.94°F) with a relative humidity of 60%RH.

If specifications are changed in the future, the product nameplate will reflect the new specifications.

The working temperature range of this machine is between 7°C(44.6°F) and 32°C(89.6°F). If the room temperature is not within this range, the unit will not operate normally.

GWP value of R410A

WARNING

This product can expose you to chemicals including Styrene and its compounds, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, please visit: www.P65Warning.ca.gov.

PRODUCT DRAWINGS

Front View

Back View

OPERATION INSTRUCTIONS

Control Panel

[Image of the control panel with various buttons and a digital display.]

Humidity Level & Timer Display

The indicator has 3 functions:

  1. When the machine is powered on, it will indicate the current room humidity.
  2. When you set the humidity, it will indicate the humidity that you have set.
  3. When you program the timer, it will show the timing duration.
  4. When the environment humidity is lower than 25%RH, it will show “25”.
  5. When the environment humidity is higher than 95%RH, it will show “95”.

Operating Instructions

When the machine is powered on for the first time, it will buzz the power sound before entering into the standby status.

Turn On/Off

Press the [Power] button to start the machine when it is powered off. Press the [Power] button to turn it off when the machine is operating.

Humidity Setting

Press the humidity button (often represented by a water droplet icon), you can press the [+] or [-] button to adjust the humidity from 30%RH to 80%RH in 5% increments. The LED display will flash when you adjust the humidity. The default humidity level is 40%RH.

Fan Speed Setting

Press the [Speed] button to switch the fan speed between low and high level. The corresponding fan speed light will turn on.

Swing Setting

When the machine is operating, press the [Swing] button to start or stop the swing of the air outlet blade.

Timer Setting

In the standby state, press the timer button (often represented by a clock icon) [Timer] to set a timer to automatically start the machine. The LED display will show the time. You can press [+] or [-] button to adjust the timer from 01 to 24 hours.

When the machine is operating, press the timer button [Timer] to set a timer to automatically shut down the machine. The LED display will show the time. You can press [+] or [-] button to adjust the timer from 01 to 24 hours.

When the dehumidifier is turned on/off by user's operations or full tank alarm, the timing function may become invalid.

DRAINAGE

MANUAL DRAINAGE

Emptying the Water Tank

When the water tank is full, the tank full indicator light [Full] will turn on, and the dehumidifier will stop automatically. The buzzer will beep 15 times to remind you to empty the water tank.

  1. Gently press the sides of the tank with both your hands and pull the tank out.
  2. Pour out the collected water.
  3. Install the water tank steadily into the machine.

[Diagrams showing steps 1, 2, and 3 for manual water tank removal and reinstallation.]

NOTE

  1. Do not remove the float from the water tank. The full tank sensor will no longer be able to detect the water level correctly without the float, and water may leak from the tank.
  2. If the tank is dirty, please wash it with cold or lukewarm water. Do not use detergent, scouring pads, chemically treated dust cloths, gasoline, benzene, thinner, or other solvents, as these may scratch and damage the tank and cause water leakage.
  3. When replacing the tank, please press the tank firmly into place with both hands. If the tank is not positioned properly, the "TANK FULL" sensor will be activated, and the dehumidifier will not operate.

CONTINUOUS DRAINAGE

  1. Take out the drain hose connector from the water tank.
  2. Unscrew the outlet cover on the back of the machine.
  3. Install the drain hose connector and connect the drain hose.
  4. The dehumidifier will continuously drain water when the drain hose is properly installed.

[Diagrams showing steps 1 through 4 for continuous drainage setup.]

Warnings:

MAINTENANCE & CLEANING

Cleaning the Dehumidifier

Cleaning the Body

Wipe it with a soft damp cloth.

Cleaning the Air Filter

  1. Open the inlet grill and wash it with water.
  2. Run a vacuum cleaner lightly over the surface of the air filter to remove dirt. If the air filter is exceptionally dirty, please wash it with warm water and a mild cleanser and dry thoroughly.
  3. Insert the filter into the grill smoothly.

[Diagrams showing steps 1, 2, and 3 for air filter cleaning.]

Storing the Dehumidifier

When the unit is not used for a long period of time or you want to store it, please follow these steps:

  1. Empty any water left in the tank.
  2. Put the power supply cord away and wrap it around the hook on the back of the unit.
  3. Clean the air filter.
  4. Place it in a cool and dry place.

Clearance

Keep a minimum clearance of 18 inches around the dehumidifier when it is operating.

[Diagram showing a dehumidifier with arrows indicating 18 inches clearance on the sides.]

TROUBLESHOOTING

The following list contains some abnormal conditions that are not faults caused by manufacturing process or material defects.

ProblemsPossible CausesSolutions
The machine doesn't operateIs the power cord connected properly?Plug the power cord into the outlet.
Is the tank full indicator flashing? (The tank is full or in a wrong position.)Empty the water tank and then reposition the tank.
Is the temperature of the room above 32°C(89.6°F) or below 7°C(44.6°F)?Make sure the working temperature is between 7°C(44.6°F) and 32°C(89.6°F).
The dehumidifying function doesn't workIs the air filter clogged?Clean the air filter as instructed under "Cleaning the dehumidifier".
Is the intake duct or discharge duct obstructed?Remove the blockage from the discharge duct or intake duct.
No air is dischargedIs the air filter clogged?Clean the air filter as instructed under "Cleaning the dehumidifier".
Is the unit tilted or unsteady?Move the unit to a stable, sturdy location.
The operation is noisyIs the air filter clogged?Clean the air filter as instructed under "Cleaning the dehumidifier".
According to "E1"Abnormal exhaust pipe temperature sensorCheck exhaust pipe temperature sensor and related circuit.
According to "E2"Abnormal coil temperature sensorCheck coil temperature sensor and related circuit.
According to "E3"Communication failureCheck to see if the main PCB is connected properly. If not, replace it with a new main PCB.
According to “EH”Abnormal humidity sensorCheck if the wires of the temperature and humidity module are loose. If not, replace the temperature and humidity module or the motherboard.

SPECIAL NOTES

  1. When using the machine, please do not put it on a soft or uneven ground to prevent vibration and movement.
  2. Do not insert any thin rods or hard items into the machine to prevent malfunctions and dangers.
  3. When using the machine, please keep it away from any heating furnaces, electric kettles, and other heating sources.
  4. When using the machine, please close doors and windows for the optimal moisture removal effect.
  5. Please do not put any objects around the machine. The dehumidification effect will be affected if the ventilation is bad.
  6. Please unplug the machine from the power source if you do not use it for a long time.
  7. When cleaning the machine, please use a wet cloth to wipe gently. Do not spray water on it directly.
  8. Please do not put any objects on the dehumidifier.
  9. Please clean the filter every two weeks. Do not use hot water above 104°F, alcohol, gasoline, or toluene.
  10. When using the hose to drain continuously, please place the hose horizontally and make sure it is even and not winded.
  11. After cleaning the filter, please do not dry it under direct sunlight to prevent it from deforming.
  12. Before moving or carrying the machine around, please empty the water tank first.

WARRANTY & CONTACT US

Warranty

Waykar offers a 12-month warranty to all of our products, starting from the original proof of purchase, for defects occurring during the Warranty Period, including those newly purchased and unused, from Waykar or through an authorized reseller, whether wholly or substantially, or as a result of faulty manufacturing parts or workmanship.

The warranty does not apply if damage is caused by other factors, including but without limitation of:

These are our general terms for warranty service, but we always encourage our customers to contact us with any issues, regardless of warranty terms. If you are experiencing an issue with a Waykar product, you can reach out to us at support@waykar.com. We will dedicate our efforts to resolve it for you.

Extend Your Warranty by 1 Year

Register your product at www.waykar.com to extend your 1-year warranty by an additional year.

*Please fill out all required fields and include your Order ID and Date of Purchase if applicable.

Customer Support

If you have any questions or concerns about our product, please feel free to contact our expert support team. Waykar customer service is ready to help.

Waykar Office

210 Henson Road Bldg A, Blacksburg, SC 29702 USA

Email: support@waykar.com

Live Chat: www.waykar.com

Support Hours

24 Hours available

*Please have your Order Number ready before contacting customer support.

Models: JD025CE-80, JD025CE-80 Energy Star Dehumidifier, Energy Star Dehumidifier, Star Dehumidifier, Dehumidifier

PDF preview unavailable. Download the PDF instead.

C1qub8S9WOL Adobe PDF library 15.00

Related Documents

Preview Waykar JD025C-80 Home Dehumidifier User Manual
Comprehensive user manual for the Waykar JD025C-80 Home Dehumidifier, covering features, safety, specifications, operation, maintenance, troubleshooting, and warranty information.
Preview Waykar Home Dehumidifier User Manual - YDZ-80, YDZ-120, YDZ-150, YDZ-150PM
Comprehensive user manual for Waykar home dehumidifiers, covering models YDZ-80, YDZ-120, YDZ-150, and YDZ-150PM. Includes setup, operation, maintenance, troubleshooting, and specifications.
Preview Waykar CFD2.5D Home Dehumidifier User Manual
Comprehensive user manual for the Waykar CFD2.5D Home Dehumidifier, covering setup, operation, safety instructions, troubleshooting, maintenance, and technical specifications.
Preview Waykar PD160B-PRO Home Dehumidifier User Manual
Comprehensive user manual for the Waykar PD160B-PRO Home Dehumidifier, covering safety precautions, operation instructions, maintenance, troubleshooting, and specifications for optimal indoor air quality.
Preview Waykar PD253B Home Dehumidifier User Manual
Comprehensive user manual for the Waykar PD253B Home Dehumidifier, covering setup, operation, maintenance, troubleshooting, and technical specifications.
Preview Waykar CPL250A Commercial Dehumidifier User Manual
User manual for the Waykar CPL250A Commercial Dehumidifier, covering safety precautions, parts illustration, installation, function overview, operation instructions, troubleshooting, specifications, maintenance, cleaning, and warranty information.
Preview Waykar AFW2.5D Commercial Dehumidifier User Manual
Comprehensive user manual for the Waykar AFW2.5D Commercial Dehumidifier, covering safety precautions, operation, maintenance, troubleshooting, specifications, and warranty information.
Preview Waykar PD160B Home Dehumidifier User Manual & Safety Guide
Comprehensive user manual for the Waykar PD160B Home Dehumidifier, covering operation instructions, safety precautions, maintenance, troubleshooting, and warranty information. Learn how to effectively use and care for your Waykar dehumidifier for optimal indoor climate control.