Installation Guide for Triple CLM models including: Water Leak Mitigation System, Water Leak, Mitigation System

MANUAL INSTALLATION CLM-MITIGATION-ONE PAGE

MANUAL INSTALLATION CLM-MITIGATION-ONE PAGE

6 On the valve closing axis, install the plastic cylinder "gripping the faucet axis" with a star shape at the lower end, and a groove in the

PDF Manual Installation Clm-mitigation-one Page

6 On the valve closing axis, install the plastic cylinder "gripping the faucet axis" with a star shape at the lower end, and a groove in the


File Info : application/pdf, 12 Pages, 2.50MB

PDF preview unavailable. Download the PDF instead.

MANUAL-INSTALLATION-CLM-MITIGATION-ONE-PAGE
Water Leak
Mitigation System
Self InstallationGuide

Thank you for purchasing the Triple+ CLMTM Mitigation system.

1 X HUB

INTHE KIT
Box Contains: Power adapter 2 X AA Backup batteries

3 X Flood Detector

Box Contains: 2 X AAA batteries

1 X Rope Detector
1 X Actuator 1 X 1" Valve Ball 1 X 1" Flow Sensor

Box Contains: 2 X AAA batteries
Box Contains: 4 X CR123A batt.

Beforeyou start
Search and download the Triple+ CLM APPavailable online or scan
the QR code
Must have 2.4GHz WiFi for Hub 2.0
Insert the supplied 2 AA backup batteries to the HUB -> HUB LED
should flash Blue
After inserting the batteries, return the bottom part back in its original place 2

Beforeyou start

B

Connect the

supplied power A

adapter to the

power port -> Wait

until HUB LED

flashes Blue. B

A
120V

Insert the 2 AAA batteries (included) into
the Flood Detectors. Flood Detector LED should flash Red and beep.

Open Back Tap

2 AAA batteries

3

Shutoff Assembly
A 1 X Flow sensor (1") B 1 X Actuator (1") C 1 X Shutoff Unit D 1 X "Neck" base connection E 1 X Plastic cylinder "grips the tap hinge" F 2 X Hexagon head bolts (8 mm) G 2 X Threaded nuts (8 mm) H 2 X Lock washers I 4 X Batteries CR123A J 1 X Emergency key

B

E I

D

C

J

FH

A

G

Tools required to install the system

1 Wrench (8 mm)

1

2 Phillips screwdriver (1-80)

2

4

System installation instructions
Close the designated water line
The system should be installed downstream and as near as possible to the water meter W in order to detect abnormal water consumption for the entire property. Important: Install the flow sensor A paying attention to the flow direction. The flow direction is indicated on the flow sensor. Then install the ball valve C
B
Flow direction

A

C

W

After installing the flow sensor and the shutoff valve open the water line and check
that there is no leakage in the connections!

1

The locking axis of the ball valve At the top of the ball valve is the closing stem the faucet; adjust the hinge groove in the same direction of water flow with a 10 mm wrench.

wrong

Right

In this position the valve is open

5

2
On the valve closing axis, install the plastic cylinder "gripping the faucet axis" with a star shape L at the lower end, and a groove in the upper part K . Make sure the direction is the same as the direction of the faucet axis.
K
L
Shutoff valve axis

Flow direction

L
3
Install the neck D Above L "grips the tap hinge". Its base will be
adjusted to the base of the ball faucet with the help of 2 screws, a locking disc and the nut.

D F
H G

R R

L R
C

The screw heads are invested in the frame R , place the locking discs H at the bottom of the screw and close the nuts with an
8mm wrench until tight.

4
N
Inserting batteries in the Actuator
Remove the plastic wrap from the batteries N . Using a Phillips A screwdriver, open the battery compartment located on the bottom of the Actuator A . Note the correct direction for their insertion to the cell; all should be facing the same direction. Close the compartment again with the Phillips screwdriver.

6

5
Battery compartment cover the screw, will activate the actuator- a green light will start flashing and the central axis will start rotating until it stops in the direction of water flow in the open position.
6
Connecting a Flow Sensor to the Actuator
Unscrew the black cap V and secure the flow sensor connector S in place. Tighten the connector tightly.
S S V

We are ready to install the Actuator on the neck 7

Y
Y D

The Actuator assembly
Release the safety catch Y with
small move back. Position the actuator on the neck and trigger.
Close the guard Y by clicking inside.
Make sure that the guard enters the entire move in place and the
Actuator locks on the neck D . Once
locked, the Actuator cannot be removed.

7

Re-open the designated water line 8
Opening and closing of the Actuator
The battery-powered actuator is Installed on a ISO5211 ball valve on the water line. The actuator can also be closed and opened manually by pressing the orange button 1 on the top for 4 seconds.
1
8

Actuator opening and closing In cases where manual operation of the faucet is required, the emergency key can be used. J In order to do this we must first release the security pin Y that locks the actuator to the neck and then remove it, while carefully pulling upwards to expose the neck. The emergency key will be inserted in the upper part of the neck, and will penetrate into the open slot designed for this purpose. When the key is in the right place we can close or open the tap by turning it.

J

OPEN

CLOSE Direction of release
J
Y

For more information or technical support visit our website
www.tripleplus.io
9

Triple+ CLMTM Hub V2.0 Wi-Fi
Installation Instructions

Download the free Triple+ CLMTM APP for

1

your smart phone from Google Play or the AppStore. The entire installation is

managed via your smartphone

You will be registering the Triple+ CLMTM

Hub V2.0 to your designated Wi-Fi network; please make sure that your

2

mobile phone is connected to that same

Note: Our network requirements are Wi-Fi 2.4GHz only (not 5GHz).

3

Read the terms and conditions, scrolling all the way down, then tap the "I Agree button" at the bottom if you approve

4 Tap the Login button

Select your language

Tap the

Fill out the

5

Create New

required fields

Account button and tap the

Accept button

Note: Ensure the complete accuracy of the email address and password requirements before accepting.

6

Tap the OK button

Tap the Add System button

Note: If you tapped the back arrow, tap on the 3 lines on the top left corner (Main Menu) -> Settings -> Add System

Scan the Kit installation QR code on the OUTSIDE of the main kit box delivered

7

Note: DO NOT scan the Triple+ CLMTM Hub V2.0 QR Codes or any individual devices) All devices in your Kit are associated to your Hub prior to delivery, and are embedded in the QR Code on the main box shipped to you.
Then tap the Add System Name button and
8 create your System- using your address is preferred, as it is unique. Then choose Region and tap the Create button.

10

Follow the instructions on the APP to initiate the installation sequence. When requested to unplug the
9 power from the Hub, please disconnect AC power first, then remove AA batteries, and reinsert AA batteries before plugging AC Power back in, then tap the "OK" button
Insert batteries back in the hub and plug in
10 the AC power, please
check to ensure that you are connected to your selected WiFi network
Note: If you do not see your network in "Your Wi-Fi network is:" -> verify that you are connected to the required network -> tap on the "X" -> Accept to cancel the installation -> connect your mobile phone to the required network -> and restart the installation. If the HUB can't connect to the Wi-Fi please refer to Technician Mode and follow the instructions.

11 After the Hub connects to the Wi-Fi the installation will start automatically

12

Locate the devices in their intended, permanent location and verify that all the devices communicate with the Triple+ CLMTM Hub V2.0 by verifying that all displaying in green. You can now secure the devices in those locations with the two-sided tape or screws.
Flood detectors must be located where water leaks can occur

Sink Water Heater Water Tank

Toilet

Water Cooler Dishwasher Washing Machine Basement 11

Optional Technician Mode Installation Procedure

Whenever the Triple+ CLMTM Hub V2.0 cannot
1 connect to the desired Wi-Fi network, please follow the following steps: A)Make sure that the Wi-Fi that you want to work with supports 2.4GHz. B)Tap on the "Technician mode" button.

Follow the instructions on the APP to initiate the

installation sequence. When requested to

2

unplug the power from the Hub, please disconnect AC power first, then remove AA

batteries, and reinsert AA batteries before

plugging AC Power back in, then tap the "OK" button.

Go to the Wi-Fi network selector on your mobile
3 phone and connect to the Triple+ WiFi network. The WiFi name will start with "Triple+" and six characters - no password is required.

Return to the Triple+ App and wait for the "Successfully connected
4 to Triple+ HUB" pop up. Tap on "Continue" and select your designated Wi-Fi network from the list. Enter password if necessary and wait for the application to give further instructions.

5

After the hub connects to the Wi-Fi the installation

will start automatically

Locate the devices in their intended, permanent

location and verify that all the devices

6

communicate with the Triple+ CLMTM Hub V2.0 by verifying that all displaying in green. You can now

secure the devices in those locations with the

two-sided tape or screws.

For more support information visit our website at:
www.tripleplus.io


Adobe PDF library 15.00 Adobe Illustrator 25.3 (Windows)