User Manual for ASEPT models including: SS1G-1 Specialty Stainless Steel Dispensers, SS1G-1, Specialty Stainless Steel Dispensers, Stainless Steel Dispensers, Steel Dispensers, Dispensers
9 hours ago — User Manual. Page 2. Specialty Stainless Steel Dispensers. Complete Pump. 2. Dome. 7299. Brush. 7615. Connector. 8359. Hose. 7368. Dome Clip. 7868. Pump Housing.
Specialty Stainless Steel Dispensers Complete Pump 2 Dome 7299 Brush 7615 Connector 8359 Hose 7368 Dome Clip 7868 Pump Housing 10196 Nozzle 8651 Model Part # 1 Gallon Jar SS1G-1 10435
File Info : application/pdf, 8 Pages, 1.61MB
DocumentDocumentSPECIALTY STAINLESS STEEL DISPENSERS User Manual Specialty Stainless Steel Dispensers 1 Gallon Jar 3 Gallon Bag-in-Box Model SS1G-1 SS3G-1 Part # 10435 10445 Complete Pump 1 Gallon Pump 10433 for a 1 gallon jar Brush 7615 3 Gallon Pump 10453 3 gallon bag-in-box Dome 7299 Pump Housing 10196 Dome Clip 7868 Nozzle 8651 Hose 7368 Connector 8359 for Pump 10453 2 Hose 10432 for Pump 10433 Safety All components must be cleaned before first use. According to food and safety regulations, most foods must be stored and/or served at certain temperatures or they could become hazardous. Check with local food and safety regulators for specific guidelines. Be aware of the product you are serving and the temperature the product is required to maintain. IMPORTANT Clean, rinse, sanitize, and dry parts at a minimum of every 24 hours. Always comply with local sanitization requirements. Cleaning Disassemble all six (6) parts. Clean with soap and hot water, rinse, sanitize and dry parts according to local sanitization requirements. Use supplied brush to scrub inside parts. All components are dishwasher safe. 3 Assembly 1 2 3 4 Mount the nozzle onto the end of the pump housing. Bend the outer portion of the nozzle inside out. Insert into opening. Tab of nozzle faces towards housing. Flip the outer portion of the nozzle over the end of tube. Insert dome into the pump housing. Ensure the flaps slide into place. Press the entire dome firmly, including the top portion. Insert the dome clip over the dome and pump housing. Ensure that the tab on bottom of the dome slides into the opening in the dome clip. Attach hose to pump housing Fit the holes in the hose over the pegs on the pump housing. 4 for Pump 10453 5 Attach connector to hose Fit the bottom holes on hose over the pegs on the connector. Hooped end of the connector must face away from pump housing. for Pump 10453 6 Connect pump to pouch Put new pouch on countertop with pouch cap facing up. Remove cap from pouch. Insert hooped end of connector into center of the pouch. Twist threaded ring on connector to secure pump to pouch. 7 for Pump 10453 Insert pouch and pump into the dispenser shroud. Hold end of pouch up while guiding the pump into the slots inside the front of dispenser. 5 for Pump 10433 7 Insert jar of product into the dispenser shroud. Insert pump hose into jar while guiding the pump into the slots inside the front of dispenser. 8 9 6 Insert the lid Hold the lever up while inserting lid tabs into slots in back of dispenser shroud. Prime pump Press lever several times until food is visible in discharge tube. Setting the Portion 1 Remove locking washer Use a flathead screwdriver to pry off the locking washer from the pin at the end of the link arms. Keep locking washer for step 4. Remove pin 2 Slide the pin out from the pair of link arms and portion holes. Select portion setting 3 Not applicable on this dispenser. 1 oz 1/2 oz 2 mL Align holes on link arms 4 with hole for desired portion setting. Slide pin through all. Secure pin with locking washer. 7 ASEPT General Warranty Liability for defects Should the products, as delivered, within one (1) year from delivery be shown to be defective due to defaults in material or manufacturing ("Warranty Period"), the Supplier undertakes, at its own option (i) to make a replacement delivery, (ii) to repair or rework the products claimed to be defective or (iii) to accept return of such product and refund such proportion of the purchase sum received as corresponds to the returned products. The Supplier assumes no liability for defects as regards to layout and design of the products, unless expressly stated in the Agreement. The Customer shall without undue delay notify the Supplier in writing of any defect which appears. Such notice shall under no circumstances be given later than two (2) weeks after the expiry of the Warranty Period. The Supplier is liable only for defect which appear under the conditions of operation provided for in the Agreement and under proper use of the product. The Supplier's liability does not cover defect which are caused by faulty maintenance, incorrect erection or faulty repair by the Customer, or by alterations carried out without the Supplier's consent in writing. Finally, the Supplier's liability does not cover normal wear and tear or deterioration. Except as expressly specified above, the Supplier has no liability for defects in the products whatsoever and are under no circumstances responsible for any direct or indirect losses, damages or costs incurred by the Customer, including consequential damages. General limitation of liability Notwithstanding any other limitation of liability mentioned in the Agreement including these Terms and Conditions, the Supplier's liability for damages under the Agreement shall be limited to the insurance compensation that can be obtained in accordance with the Supplier's each valid liability insurance. Consequential losses There shall be no liability of either party towards the other party for loss of production, loss of profit, loss of use, loss of contract or for any other consequential or indirect loss whatsoever. Tips & Troubleshooting Prevent leaks: Ensure that dome is pushed fully into pump housing. Ensure any attached pouch is secured tightly to pump. Pro Tip: Clean water may be used as lubrication when fitting hose onto pegs. Optimize pouch evacuation: Ensure ramp is in place. Asept International Inc. 900 Oakmont Ln, Suite 207, Westmont IL 60559, USA +1 (630) 441-5656 info.us@asept.com 8 Asept International AB Traktorvägen 17, SE-226 60 Lund, Sweden +46 46 329 700 info@asept.com www.asept.com 330015 11/20