User Manual for SAMCON models including: ExCam IPQ6075 Ex-proof Dome Camera, ExCam IPQ6075, Ex-proof Dome Camera, Dome Camera, Camera
Information, and about Hazardous Areas
ExCam IPQ6075 - Ex-proof Dome Camera - IECEx EAC-Ex blast proof
File Info : application/pdf, 28 Pages, 1.60MB
DocumentDocumentExCam® IPQ6075 User Manual Table of contents 1 Introduction .............................................................................................................. 4 2 Technical data .......................................................................................................... 4 2.1 Explosion protection ............................................................................................ 4 2.2 Illustration of the model key.................................................................................5 2.3 Electrical parameters of the camera....................................................................6 2.4 Connection cable Ex-d - Ex-e..............................................................................6 2.4.1 Connection cable for models -N- (SKD02-T)............................................................................. 6 2.4.2 Connection cable for models with heater (SKDP03-T).............................................................. 7 2.5 Video-technical characteristics ............................................................................ 7 2.6 Other technical data ............................................................................................ 7 3 Safety Instructions ................................................................................................... 8 4 Assembly .................................................................................................................. 9 5 Electrical connection ............................................................................................. 11 5.1 Equipotential bonding/Grounding ...................................................................... 12 5.2 Connection work on the device (terminal box) .................................................. 13 5.3 External connection and protection ................................................................... 17 5.3.1 Direct routing from the ExTB-3 into the safe area ................................................................... 17 5.3.2 Routing via ExConnection Rail (optional accessories) ............................................................ 18 5.3.3 Appropriate cables & cable entries .......................................................................................... 19 5.3.4 Fusing ...................................................................................................................................... 20 5.3.5 Plug assignment (RJ45) .......................................................................................................... 21 5.3.6 Tests prior to switching on voltage .......................................................................................... 22 6 Opening the pressure-resistant housing ............................................................. 22 7 Network access and visualization ........................................................................ 23 7.1 Browser Support................................................................................................ 23 7.2 Assigning the IP address...................................................................................23 7.3 Password/ Identification .................................................................................... 24 8 Maintenance/ Modification.....................................................................................25 9 Reparation...............................................................................................................25 10 Disposal/ Recycling ............................................................................................ 25 11 Drawings & 3D models ....................................................................................... 26 12 Notes .................................................................................................................... 27 Doc.-ID: 200630-PT08BA-ES-ExCam IPQ6075_en_rev.02.docx, Page 2 of 28 Table of Figures and Charts Tab.2-1 Model key .......................................................................................................... 5 Fig. 2-1 Sectional view of SKD02-T...................................................................................6 Fig. 2-2 Sectional view of SKDP03-T ................................................................................7 Tab. 2-2 Other technical data ............................................................................................ 7 Tab. 4-1 Mounting Accessories ....................................................................................... 10 Fig. 5-1 ExCam IPQ6075 equipotential bonding..............................................................12 Tab. 5-1 Equipotential Bonding ....................................................................................... 12 Fig. 5-2 Camera (Ex-d) and terminal box (Ex-e)..............................................................13 Fig. 5-3 Video Tutorial ExTB-3 ........................................................................................ 14 Tab. 5-2 Wire assignment of terminal box ExTB-3 (model N)..........................................14 Tab. 5-3 Wire assignment of terminal box ExTB-3 (model LL) ........................................14 Fig. 5-4 Sample circuit of terminal box ExTB-3 (model N) ............................................... 15 Fig. 5-5 Sample circuit of terminal box ExTB-3 (model LL) ............................................. 16 Fig. 5-6 Photo of the occupied terminal box ExTB-3 ....................................................... 16 Fig 5-7 ExTB-3 -> Safe area............................................................................................17 Fig. 5-8 ExTB-3 -> ExConnection Rail.............................................................................18 Figure 5-9 Ex-d cable selection ....................................................................................... 19 Fig. 5-10 Barrier gland ..................................................................................................... 20 Tab. 5-4 Recommendation for fusing .............................................................................. 20 Fig. 5-11 Plug assignment RJ45......................................................................................21 Fig. 7-1 Axis IP Utility ...................................................................................................... 24 History of revisions Product: Title: Doc. -Id. Author: Created on: ExCam® IPQ6075 User Manual for ExCam® IPQ6075 200630-PT08BA-ES-ExCam IPQ6075_en_rev.02.docx Eva Schneider, Grad. Eng. (FH) 30.06.2020 Rev. Index 0 1 2 Date 30.06.2020 Name Comment E. Schneider Compilation of the document 16.11.2020 25.01.2023 E.Schneider Different corrections E.Schneider Change of EAC-Ex Certificate Approved by the ATEX Supervisor Thiemo Digital unterschrieben von Thiemo Gruber DN: cn=Thiemo Gruber, o=Samcon Gruber GmbH, ou=Hardware Entwicklung, email=t.gruber@samcon.eu, c=DE Datum: 2023.01.25 14:40:03 +01'00' Doc.-ID: 200630-PT08BA-ES-ExCam IPQ6075_en_rev.02.docx, Page 3 of 28 1 Introduction In the ExCam IPQ6075 is a powerful IP dome camera of the latest generation, with 2megapixel resolution at 1920x1080p points. It is certified by ATEX, IECEx & EAC-Ex (and more). This dome camera can endlessly rotate around its own axis. This is done with a high speed and precision. Thanks to the Lightfinder-Technology you receive sharp images and superior details even in demanding light conditions. Not only the excellent light sensitivity makes this camera that special but also the 40-fold optical zoom produces sharp, precise images and brilliant wide-angle images. The ExCam series is certified both in accordance with the European (ATEX) and international directive (IECEx). The explosion-protected housing is approved for the ATEX group II for zones 1, 2, 21 and 22 including the explosion groups IIC / IIIC. To see other approvals, please visit our website at www.samcon.eu In designing the ExCam IPQ6075, we attached a very high importance to safety, mechanical precision and high quality of stainless steel. 2 Technical data 2.1 Explosion protection Identification marks acc. to Directive 2014/34/EU: Explosion protection (gas): Explosion protection (dust): Protection class: Transport/storage temperature: Ambient temperature (EX): Named testing laboratory: EU type approval certificate: IECEx Certificate of Conformity: EAC-Ex TUR Report: Other certificates: II 2G (zone 1 and 2) II 2D (zone 21 and 22) Ex db IIC T6 Gb Ex tb IIIC T80°C Db IP 68 (IEC /EN 60529) 0°C...+40°C 0°C...+60°C (Type...N.H...) -50°C...+60°C (Type...LL.H...) TÜV Rheinland (number 0035) TÜV 18 ATEX 8218X IECEx TUR 18.0023X (2018) RU C-DE.HA65.B.01652/22 see https://www.samcon.eu/en/products/network/excam-ipq6075 Doc.-ID: 200630-PT08BA-ES-ExCam IPQ6075_en_rev.02.docx, Page 4 of 28 Attention! The instructions stated on the type plates have to be observed! 2.2 Illustration of the model key 1) Ex productname ExCam IPQ6075 2) Type T08T08T08T08- 3) Housingcombination TNXCDTNXCDTNXCDTNXCD- 4) Temp.range N.HN.HLL.HLL.H- 5) Cable length [m] 6) Cable termin. 005.N005.N005.N005.N- PTPTTab.2-1 Model key Explanations: 1) ExCam IPQ6075 = 2) T08 = 3) TNXCD = 4) N.H = N.H= LL.H= 5) 005.N = 005.N = 6) P = T = Functional camera description of the ExCam Series (technical data/ specification of the individual camera module) SAMCON Production- Type 08 Dome-housing (stainless steel 1.4404) Normal ambient temperature range, no heater installed (Tamb > 0°C) High temperature (Tamb < +60°C) PTC heater installed (Tamb > -50°C) Length of the connection line in meter at delivery; 5m is the standard cable length, max. cable length is: 003...100 [m] for modelkey -N- and 003...100 [m] for model key LLNon armoured cable Plug- termination (standard) CAT6, RJ-45 network plug (heavy duty), AWG 26-22, contact assignment acc. To specification EIA/TIA-568B Terminal Box termination (optional) 4 x PoE Mode A connection (camera PoE) 24VDC (Heater) (see chapter electrical connection) Doc.-ID: 200630-PT08BA-ES-ExCam IPQ6075_en_rev.02.docx, Page 5 of 28 2.3 Electrical parameters of the camera 24VDC Power input: Permissible temperature range: Power supply: Power consumption: -50°C < Tamb < +60°C 24 VDC approx. 60W@-50°C (depends on the temperature) PoE+ Power input: Permissible temperature range: Power supply: Reference voltage: Maximum power consumption: Typical power consumption: -0°C < Tamb < +60°C PoE, IEEE 802.3at class 4 48 VDC (44...54 VDC) 17.1 W 11.0 W 2.4 Connection cable Ex-d - Ex-e Description: Jacket colour: Data transfer and power supply of the camera module (compliant with DIN EN 60079-14), green (GN), similar to RAL3001 2.4.1 Connection cable for models -N- (SKD02-T) Systemcable SKD02-T: Outside diameter: 8.9 ± 0.3 mm Bending radius: 8 x Da when installed and 4 x Da after relocation Data line: 4 x 2 x AWG23/1 CAT.6 Properties: PUR halogen-free, flame-retardant, UV-re- sistant, chemical resistance, shielded Quick link: https://www.samcon.eu/fileadmin/documents/en/60-Assembling%26mounting/SKD02-T_Datasheet.pdf Fig. 2-1 Sectional view of SKD02-T Doc.-ID: 200630-PT08BA-ES-ExCam IPQ6075_en_rev.02.docx, Page 6 of 28 2.4.2 Connection cable for models with heater (SKDP03-T) Systemcable SKDP03-T: Outside diameter: 12.40 ± 0.3 mm Bending radius: 8 x Da when installed and 4 x Da after relocation Data line: 4 x 2 x AWG23/1 CAT.6 Performance elements: 3G1.5 (BK-BU-GN/YE) Properties: PUR halogen-free, flame-retardant, UV-re- sistant, chemical resistance, shielded Quick link: https://www.samcon.eu/fileadmin/documents/en/60-Assembling%26mounting/SKDP03-T_Datasheet.pdf Fig. 2-2 Sectional view of SKDP03-T 2.5 Video-technical characteristics We use the AXIS Q6075 Dome Camera in a pressure-resistant enclosure. For details, please refer to the Product Documentation, video-technical data of AXIS®: http://www.axis.com/products/axis-q6075 2.6 Other technical data Permissible ambient temperature Protection class as per EN 60529/IEC 529 Housing material Weight Dimensions Camera (Ex-d) 0°C ... +60°C (for PoE+ power supply) -50°C ... +60°C (at 24 VDC power supply) IP68 (Test conditions: 24h/3m water column 5°C) - stainless steel, mat. no. 1.4404 - LEXAN about 20 kg D195mm x 378mm Terminal box (Ex-e) -60°C ... +55°C IP66 polyester resin about 1 kg 145mm x 145mm x 71mm Tab. 2-2 Other technical data Doc.-ID: 200630-PT08BA-ES-ExCam IPQ6075_en_rev.02.docx, Page 7 of 28 3 Safety Instructions Please absolutely observe the safety directions stated in the Ex-installation instructions of the T08 ExCam series! Quick link: https://www.samcon.eu/fileadmin/documents/en/22-Ex-Network-Cameras/ExCam-Series-T08-EX-Installation-Manual-2020.pdf It is absolutely mandatory to observe the national safety regulations and regulations for prevention of accidents, as well as the safety instructions given below in this User Manual! Attention! Cameras of the type T08 ExCam are not suitable for use in zone 0 and zone 20. The ambient temperature, temperature class and explosion group as stated on type plate must be observed! Alterations are not permitted! The camera is to be operated in sound conditions and in the intended way. Attention! Only original parts of SAMCON Prozessleittechnik GmbH may be used for repairs. Repairs concerning the explosion protection may only be carried out in accordance with the nationally applied regulations and by SAMCON Prozessleittechnik GmbH. Attention! Prior to installation, take external sources of heat or cold into account! The temperature ranges prescribed for storage, transport and operation must be adhered to! Attention! Observe the warnings given on the type plate: "WARNING DO NOT OPEN IN HAZARD AREAS" "WARNING DO NOT OPEN WHILE ENERGIZED" The use in hazardous areas with regard to temperature and dust layers is defined in the respective national regulations. When installing the ExCam, adhere to the requirements of the EN/IEC 60079-14. Doc.-ID: 200630-PT08BA-ES-ExCam IPQ6075_en_rev.02.docx, Page 8 of 28 4 Assembly For erecting and operating the camera, the relevant national regulations, as well as the generally accepted rules of technology shall prevail. Before mounting the camera, thoroughly check it for any transport damage, especially regarding the housing and the cable. Installation, electrical connection and the commissioning must only be carried out by qualified specialists. Work preparation: Attention! Prepare your work carefully and in accordance with the relevant regulations. Attention! Depending on classification of hazard areas, a work approval has to be obtained. When you open the pressure-resistant enclosure under voltage, it is absolutely necessary to prevent potentially explosive atmosphere! To ensure the best image quality delivered by the network camera, plan the installation site carefully (consider light conditions, object distance or size, angle and minimum object distance to the focus). Use appropriate tools and aids When working, ensure a safe stand. Make sure that any static charge is avoided Attention! Please pay attention to the national security, installation and accident prevention regulations (e.g. DIN EN 60079-14) and the safety instructions given below in this User Manual, as well as the ones in the Installation Guidelines! Attention! Adhere to the provisions of the IECEx ATEX and EX installation instructions for mounting and starting up! ExCam® IPQ6075 consists of a flame-proof camera housing (Ex-d) and optionally (models with a terminal box ...-T), a terminal box of a high degree of safety (Ex-e). Both areas are separated by a reinforced 5 m line. Mount the camera as high as possible, according to the desired field of view. Doc.-ID: 200630-PT08BA-ES-ExCam IPQ6075_en_rev.02.docx, Page 9 of 28 Install the connection chamber so that a good accessibility is provided, in order to facilitate electrical connection. Attention! Please pay attention to the national and local regulations for mounting heavy loads. In case of doubt, take appropriate security measures. Drawings for drill hole patterns and further information can be viewed on our product page: Quick link: https://www.samcon.eu/en/products/network/excam-ipq6075/ Option mounting accessories Wall bracket WMB-... Pole adapter PMB-... Ceiling adapter CMB-... WALL MOUNT EXCAM TNXCD Wall bracket for the T08-TNXCD series Suitable for hanging the camera on walls. The scope of delivery includes a protective cover for the wall bracket. The cover protects the cable and cable routing as required by 60079-14 and does not let the cable and cable glands be directly exposed to water splashes. Material: stainless steel 1.4404 Load bearing: 45 kg Dimensions: 460 x 140 x 220 mm POLE MOUNT EXCAM TNXCD TNXCD pole adapter for wall mount Material: stainless steel 1.4404 Suitable for pole diameters between 110 and 150 mm Load-bearing capacity: 50 kg CEILING MOUNT EXCAM TNXCD TNXCD pole adapter for ceiling mount Material: stainless steel 1.4404 Load-bearing capacity: 50 kg Tab. 4-1 Mounting Accessories Doc.-ID: 200630-PT08BA-ES-ExCam IPQ6075_en_rev.02.docx, Page 10 of 28 5 Electrical connection Attention! The electrical connection of the equipment must only be carried out by officially qualified and skilled personnel! Attention! It is absolutely necessary to ground the ExCam® series housing via the PA connection. Attention! The minimum length of the connecting cable must not be less than three meters! The connection cable must be protected! Attention! Please pay attention to the national security, installation and accident prevention regulations (e.g. DIN EN 60079-14) and the safety instructions given below in this User Manual, as well as the ones in the Installation Guidelines! The ExCam® IPQ6075 is equipped with an electrical connection cable of the type SKD02-T (models with the model key -N-) or SKDP03-T (models with model key -LL-) and optionally, a pre-assembled and pre-wired terminal box ExTB-3. The maximum transmission range from the camera to the next active network interface is 100 meters and can be individually specified by the client. The user is NOT authorised to do any electrical connection procedures inside the pressure-resistant enclosure. Doc.-ID: 200630-PT08BA-ES-ExCam IPQ6075_en_rev.02.docx, Page 11 of 28 5.1 Equipotential bonding/Grounding Fig. 5-1 ExCam IPQ6075 equipotential bonding Equipotential bonding/grounding of the camera body is absolutely necessary, in order to avoid static charges and formation of sparks. For this purpose, a screw terminal is provided at the rear side, at the bottom (right) (see Figure 5.1). The cross-section of the equipotential bonding should comply with the National Ground Rules (at least 4 mm2). Wiring table: Potential PA Colour (IEC 60757) GN/YE Cross-section 4 mm2 (rigid) Comment - Tab. 5-1 Equipotential Bonding Doc.-ID: 200630-PT08BA-ES-ExCam IPQ6075_en_rev.02.docx, Page 12 of 28 5.2 Connection work on the device (terminal box) Possible terminations are: terminal box or plug. ExTB-3 Fig. 5-2 Camera (Ex-d) and terminal box (Ex-e) Attention! Never open the Ex-e terminal box under voltage! Attention! Adhere to the international installation regulations for connection chambers with increased safety (Ex-e). Attention! Adhere to attached separate Usual Manual for the Ex-e connection chamber. Video Tutorial: Observe our video tutorial: "SAMCON 01 Installation and Wiring Connection to ExTB-3" https://go.samcon.eu/v01 Doc.-ID: 200630-PT08BA-ES-ExCam IPQ6075_en_rev.02.docx, Page 13 of 28 Fig. 5-3 Video Tutorial ExTB-3 The pin assignment of the SKD02-T is executed in accordance with the standard EIA/TIA- 568B for 100BaseTX and 24VDC, as follows: Camera (Ex-d) (T568B) Tx+ TxRx+ Rx- (PoE +48 VDC) (PoE +48 VDC) (PoE GND) (PoE GND) GND/SHD Colour SKD02-T (IEC60757) WH / OG OG WH / GN GN WH / BU BU WH / BN BN YE / GN Terminal Cross-sec- Comment ExTB-3 tional sur- face 1 0.26 mm2 Solid conductor 2 0.26 mm2 Solid conductor 3 0.26 mm2 Solid conductor 4 0.26 mm2 Solid conductor 5 0.26 mm2 Solid conductor 6 0.26 mm2 Solid conductor 7 0.26 mm2 Solid conductor 8 0.26 mm2 Solid conductor PE 2.5 mm2 Flex Tab. 5-2 Wire assignment of terminal box ExTB-3 (model N) The pin assignment of the SKDP03-T is executed in accordance with the standard EIA/TIA- 568B for 100BaseTX and 24VDC, as follows: Camera (Ex-d) (T568B) Tx+ TxRx+ Rx- (PoE +48 VDC) (PoE +48 VDC) (PoE GND) (PoE GND) GND/SHD L+ LPE Colour SKDP03-T (IEC60757) WH / OG OG WH / GN GN WH / BU BU WH / BN BN YE / GN BK BU YE / GN Terminal Cross-sec- Comment ExTB-3 tional sur- face 1 0.26 mm2 Solid conductor 2 0.26 mm2 Solid conductor 3 0.26 mm2 Solid conductor 4 0.26 mm2 Solid conductor 5 0.26 mm2 Solid conductor 6 0.26 mm2 Solid conductor 7 0.26 mm2 Solid conductor 8 0.26 mm2 Solid conductor PE 2.5 mm2 Flex 9 1.5 mm2 L+ 24VDC 10 1.5 mm2 L- 24VDC PE 1.5 mm2 PE Tab. 5-3 Wire assignment of terminal box ExTB-3 (model LL) Doc.-ID: 200630-PT08BA-ES-ExCam IPQ6075_en_rev.02.docx, Page 14 of 28 SKD02-T SKD02-T ExCam IPQ6075 Fig. 5-4 Sample circuit of terminal box ExTB-3 (model N) Doc.-ID: 200630-PT08BA-ES-ExCam IPQ6075_en_rev.02.docx, Page 15 of 28 ExCam IPQ6106745 Fig. 5-5 Sample circuit of terminal box ExTB-3 (model LL) Fig. 5-6 Photo of the occupied terminal box ExTB-3 Doc.-ID: 200630-PT08BA-ES-ExCam IPQ6075_en_rev.02.docx, Page 16 of 28 Attention! Perform the foiling up to about 10mm to the terminals, in order to prevent alien crosstalk. Make sure that the foiling cannot cause any short circuit of the data couples! Attention! Bring the twisted pair composite approximately 10mm close to the terminals, in order to ensure the immunity to disturbance. Attention! Use only terminals approved by SAMCON. Attention! Finally, check your network installation by per Class-D Link Test. 5.3 External connection and protection There are several options of assigning the ExTB-3 terminal box in a safe area: 5.3.1 Direct routing from the ExTB-3 into the safe area Fig 5-7 ExTB-3 -> Safe area In the case of direct routing from ExTB-3 into the safe area, the power supply and the voltage signal is led from the safe area to the terminal box. Please observe the terminal box assignment, as described above. Doc.-ID: 200630-PT08BA-ES-ExCam IPQ6075_en_rev.02.docx, Page 17 of 28 Attention! Cables and wires must comply with the requirements of the IEC 60079-0/1/7 & 14. Attention! The supply line must have a sufficient cross-section. The cable protection must comply with national and international regulations. 5.3.2 Routing via ExConnection Rail (optional accessories) Fig. 5-8 ExTB-3 -> ExConnection Rail In the case of routing the ExTB-3 into a larger ExConnection Rail, larger installation distances can be managed. Note: In explosive areas ExConnection Rail (optional accessories) acts as PoE+ switch, media converters from copper to fibre-optic cable, as well as a power supply to the cameras. Attention! Cables and wires must comply with the requirements of the IEC 60079-0/1/7 & 14. Attention! The supply line must have a sufficient cross-section. The cable protection must comply with national and international regulations. Doc.-ID: 200630-PT08BA-ES-ExCam IPQ6075_en_rev.02.docx, Page 18 of 28 5.3.3 Appropriate cables & cable entries To ensure the device safety, you should correctly select the right cables, wires and cable glands. Attention! Cables and wires must comply with the requirements of the IEC 60079-0/1/7 & 14. Attention! The supply line must have a sufficient cross-section. The cable protection must comply with national and international regulations. To see non-binding configuration and planning guidelines, please visit: https://www.samcon.eu/fileadmin/documents/en/99-Knowledgecenter/TB003-Cable-Gland-selection-for-Ex-d-enclosures.pdf Perhaps our video will help you: "Cables for flameproof devices in potentially explosive atmospheres" http://go.samcon.eu/video-cable-ex Figure 5-9 Ex-d cable selection In particular for installations which require a suitable barrier gland, make sure that you handle them correctly and adhere to the rules and notes given in the respective mounting instructions. We show the essential procedures in the following video tutorial: Video Tutorial: Observe our video tutorial: "SAMCON 02 Installation Ex d gland" https://go.samcon.eu/v02 Doc.-ID: 200630-PT08BA-ES-ExCam IPQ6075_en_rev.02.docx, Page 19 of 28 Fig. 5-10 Barrier gland 5.3.4 Fusing PoE+ power supply requires no fuses. The power supply fusing depends on the cable cross-section and length. Attention! Recommendation for fusing relates to 60W@24VDC at 100meters 1.5 mm2 Attention! When the heating switches on, there are high current peaks! Use slowblow fuses. Attention! Please pay attention to the national and international regulations regarding selectivity and line protection. Potential/ Colour Wire no. (IEC60757) L+ / 1 BK L- / 2 BU PE YE/GN Conductor Voltage 1.5mm2, stranded wire 1.5mm,2, stranded wire 1.5mm,2, stranded wire +24 VDC 0 VDC / GND PE Maximum power consumption/fusing: 60 W of continuous power Fine-wire fuse (L+) 6000 mA -T- slow-blow (high inrush load!) Tab. 5-4 Recommendation for fusing Doc.-ID: 200630-PT08BA-ES-ExCam IPQ6075_en_rev.02.docx, Page 20 of 28 5.3.5 Plug assignment (RJ45) The data transfer of the ExCam IPQ6075 series uses a 100 Mbit/s Ethernet connection (100BASE-TX). If the cable termination uses a plug it has to be plugged into the associated slot of the network device. Prior to connecting it to the camera, the network device (PSE) can already be supplied with power, hence there is no ,,power ON" priority which has to be observed. Attention! Use the appropriate RJ45 plug! Check shielding, cross-section and the outside diameter of the cable! Attention! It is imperative to ensure a correct assignment of the individual wires according to the EIA/TIA-568B" Attention! Finally, check your network installation by per Class-D Link Test. Observe our video tutorial: "SAMCON 03 Mounting and installing the RJ45 jack to SAMCON cables" https://go.samcon.eu/v03 Fig. 5-11 Plug assignment RJ45 Doc.-ID: 200630-PT08BA-ES-ExCam IPQ6075_en_rev.02.docx, Page 21 of 28 5.3.6 Tests prior to switching on voltage Attention! Prior to commissioning, all tests as indicated by the national regulations have to be executed. Furthermore, the correct function and installation of the device has to be checked in accordance with this user manual and other applicable regulations. Attention! Incorrect installation and operation of the camera may lead to a loss of warranty! Attention! Do not switch on the camera at temperatures below 0°C! 6 Opening the pressure-resistant housing To open the TNXCD housing, you need a special tool. The customer should not open it. If you think that the housing has to be opened for unforeseeable reasons, please contact our support team at first (support@samcon.eu). Always adhere to the explosion-relevant rules: ,,WARNING MAY NOT BE OPENED IN HAZARD AREAS" Note: Depending on classification of hazard areas, a work approval has to be obtained. Even after switching on the power supply, it is absolutely imperative to avoid potentially explosive atmosphere when opening the camera housing. Opening the housing requires disassembly and working in a safe (i.e. non-explosive!) area. Attention! Heed that you do not damage the thread surface of the flame-proof gap. Attention! Heed that you do not damage the housing seals. Keep them clean! Doc.-ID: 200630-PT08BA-ES-ExCam IPQ6075_en_rev.02.docx, Page 22 of 28 7 Network access and visualization The most important procedures of the first starting up the camera are described below. The configuration menu of the web surface allows an intuitive navigation and offers several configuration possibilities. For detailed documentation and information how to use the web Interface, please see the User Manual for Axis or visit the following website: http://www.axis.com/products/axis-q6075 At delivery, the ExCam IPQ6075 is set to the applicable net frequency (50Hz or 60Hz). If the camera is used at a location with a differing net frequency, a flickering of the picture might be noticeable, particularly in surroundings with fluorescent tubes. In such a case, the applicable settings have to be carried out within the menu "System Options > Advanced > Plain Config". User: root Password: root 7.1 Browser Support A list of the currently supported web browsers, operating systems, required add-ons, etc. can be viewed at: https://help.axis.com/de-de/access-your-device https://www.axis.com/de-de/support 7.2 Assigning the IP address The ExCam IPQ6075 is intended for use in an Ethernet network and requires an IP address to access and control it. In the most today's networks, a DHCP server is integrated. This server automatically assigns an IP address. If there is no DHCP server available in the network, the ExCam IP's default address is "192.168.0.90" (subnet masking 255.255.255.0). With the AXIS IP Utility, it is possible to determine the IP address under Windows. Doc.-ID: 200630-PT08BA-ES-ExCam IPQ6075_en_rev.02.docx, Page 23 of 28 In case it is not possible to assign the IP address, it might be necessary to change the firewall settings! The "AXIS IP Utility" tool automatically recognizes all ExCam devices and visualises them in the device list. It can also be used to manually assign a static IP address. For this purpose, the ExCam IPQ6075 network camera has to be installed in the same physical network segment (physical subnet) as the computer on which the AXIS IP Utility is running. The network signature of ExCam IPQ6075 is "AXIS Q6075" (see Figure 7.1). MAC address and serial number for clear device identification are also detected and displayed. ExCam IP1377 ExCam Q6075 7.3 Password/ Identification The following user name is set at the factory: root The following password is set at the factory: root Fig. 7-1 Axis IP Utility Doc.-ID: 200630-PT08BA-ES-ExCam IPQ6075_en_rev.02.docx, Page 24 of 28 8 Maintenance/ Modification The applicable regulations for the maintenance and servicing of electrical devices in potentially explosive atmospheres must be adhered to. The required maintenance intervals are specific to the individual devices. The operating company has to determine these intervals depending on the application parameters. The maintenance tasks especially include examination of parts on which the ignition protection depends (e.g., proper condition of the casing, seals and cable entry points). If maintenance measures are necessary they have to be initiated and/or executed. 9 Reparation Reparations must only be carried out with original parts of SAMCON Prozessleittechnik GmbH. Damaged pressure-resistant housings have to be replaced completely. In case of doubt, send the part in question back to SAMCON Prozessleittechnik GmbH. Reparations affecting the explosion protection must only be carried out in accordance with nationally applicable regulations - by SAMCON Prozessleittechnik GmbH or by an electrician specially authorised by SAMCON Prozessleittechnik GmbH. Rebuilding of or alterations to the devices are not permitted! 10 Disposal/ Recycling When disposing of the device, nationally applicable regulations must be observed. This Document is subject to alterations and additions. Doc.-ID: 200630-PT08BA-ES-ExCam IPQ6075_en_rev.02.docx, Page 25 of 28 11 Drawings & 3D models All drawings, 3D models, certificates and other information are available in the download area of the product page on our website: https://www.samcon.eu/en/products/network/excam-ipq6075/ If you wish additional technical information, please contact us at: support@samcon.eu Doc.-ID: 200630-PT08BA-ES-ExCam IPQ6075_en_rev.02.docx, Page 26 of 28 12 Notes Doc.-ID: 200630-PT08BA-ES-ExCam IPQ6075_en_rev.02.docx, Page 27 of 28 Schillerstraße 17, 35102 Lohra-Altenvers www.samcon.eu, info@samcon.eu fon: +49 6426 9231-0, fax: - 31