1- TECHNICAL CHARACTERISTICS

Power Supply 14-24 Vac/Vdc
Consumption 20mA standby, max. 50mA
No. of relays 2
Relay contact Clean contact 5A 30Vdc / 5A 250Vac
Relay configuration Bistable, impulse, timed (seconds and minutes)
Radio frequency 433.92-868 MHz
Max. number of memorizable codes 40
Dimensions 53x76x24 mm
Operating temperature -20° C / +70° C

2- WARNING

Dear customer, thank you for purchasing one of our products. Please read and keep this instruction manual carefully, as it provides important information about the operation and safety of the device.

The descriptions and diagrams in this brochure are not binding. Anprin Traders, S.L., while maintaining the essential characteristics of the equipment, reserves the right at any time and without obligation to update this brochure due to technical improvements or for any other commercial reason.

The equipment must be used exclusively for the purpose for which it was designed. Any other use must be considered improper and therefore dangerous.

ATTENTION: Loss of power returns the output to its standby state, i.e., open contact.

Impulse (factory setting): the relay contact remains closed for the entire duration of the press on the associated remote control; it opens when released. ATTENTION: any disturbance may open the contact even if the remote control button is still pressed.

Second timer: in this mode, it is possible to configure a time in seconds after which the relay contact opens. The timer has a factory setting of 30 seconds. ATTENTION: the timer resets every time a remote control is pressed.

Minute timer: in this mode, it is possible to configure a time in minutes after which the relay contact opens. By default, the timer has a setting of 30 minutes. ATTENTION: the timer resets every time a remote control is pressed.

6.1- Relay 1 and 2 Configuration:

Press and hold the S button on the receiver for about 5 seconds. The LED L1 for relay 1 starts flashing. To switch to relay 2, press the S button again, then LED L2 starts flashing.

The LED (L1 or L2) of the selected relay flashes according to the configured mode:

1 Flash BISTABLE
2 Flashes IMPULSE
3 Flashes SEC. TIMER
4 Flashes MIN. TIMER

Press the P button to change to the desired operating mode. Each time the P button is pressed again, the configuration cycles to the next mode.

Exit configuration by repeatedly pressing the S button until the LEDs turn off.

6.2- Timer Configuration:

While in timer mode (seconds or minutes), press and hold the S button for approximately 2 seconds and wait for the LED (L1 or L2) to flash regularly (one flash per second).

Press and hold the S button and count the number of LED flashes you want to configure as seconds or minutes. Example: Count 5 LED flashes to set 5 seconds / minutes depending on the previously selected mode.

Once you have counted the desired flashes, release the S button.

3- WARRANTY CONDITIONS

The product is guaranteed for a period of 24 months from the date of manufacture or from the documented installation date. This warranty is void in case of missing label, improper handling or use, damage caused by atmospheric events, or in any case not dependent on the product's construction and quality. The warranty is also void if original manufacturer parts are not used for repair or maintenance.

4- TRANSMITTER PROGRAMMING

Up to 40 codes can be registered in the receiver. NOTE: each remote control button corresponds to a code. Example: if all channels of a 4-button remote control are programmed, 4 codes are entered into the receiver.

Press the P button on the receiver to select relay 1, the LED L1 starts flashing. To switch to relay 2, press the P button again, LED L2 starts flashing.

Once the desired relay is selected, press the remote control button you wish to program and keep it pressed until the L1 and L2 LEDs remain lit. It may take a few seconds for the receiver to decode the new code.

Repeat the operation for all codes you wish to enter into the receiver.

4.1 - HCS Transmitter Programming Procedure:

Press the P button on the receiver to select relay 1, LED L1 starts flashing. To switch to relay 2, press the P button again, LED L2 starts flashing.

After selecting the desired relay, press the remote control button you wish to program and keep it pressed until the relay LED (L1 or L2) emits 2 slow flashes.

Transmit the SEED via the hidden key or button combination. If you do not know the procedure or cannot transmit the SEED code, continue pressing the button of the remote control you are trying to program; it will be stored as a fixed code.

5- TRANSMITTER CANCELLATION

This function allows you to individually delete remote controls from the receiver:

Press the P button on the receiver, LED L1 starts flashing, then press the S button.

LEDs L1 and L2 light up steadily.

Press and hold the button of the remote control you want to delete until LEDs L1 and L2 turn off. The remote control has been successfully deleted.

Repeat the operation for all codes you wish to delete.

6- RELAY CONFIGURATION

The relays can be configured in four different ways:

7- TOTAL RESET

This function allows you to erase all remote controls from the receiver.

Press and hold the P and S buttons for about 10 seconds, wait until LEDs L1 and L2 flash rapidly, then release the buttons.

8- ERROR CODES

Error codes are identified by LEDs L1 and L2:

L1 L2 Description
Flash Code not found
Flash Flash Memory full
Flash Flash Frequency memory full

9- PRODUCT DISPOSAL

The disposal of the device must be carried out in accordance with current regulations on electrical equipment, and it is recommended to separate it from domestic waste by contacting local waste collection centers.

6- ERROR CODES

The error codes are identified by LEDs L1 and L2:

L1 L2 Description
Flash Code not found
Flash Flash Memory full
Flash Flash Frequency memory full

Code not found: during the deletion of a remote control, it is not recognized correctly. Verify that it was previously stored and try the deletion operation again.

Memory full: the receiver memory is full and you want to program a new remote control. Delete an unused remote control and try again.

Frequency memory full: you are trying to add a new remote control with a transmission frequency different from the previous ones. The number of frequencies that can be memorized in the receiver is limited, but you will still be able to memorize other remote controls with the same frequencies as the previous ones.

PDF preview unavailable. Download the PDF instead.

Mini-recepteur-universel-HR-RX2MFM-433-868-MHz GPL Ghostscript 9.55.0

Related Documents

Preview HR-30BTL Portable DSP Radio with Bluetooth - User Guide
This document provides specifications, operation instructions, and FCC compliance information for the HR-30BTL portable DSP radio with Bluetooth connectivity.