product overview for Hamilton models including: Microlab NIMBUS, Hamilton, Automated Liquid Handler, Pipetting Workstation, NIMBUS384, NIMBUS96, NIMBUS4, laboratory automation, liquid handling, CO-RE, air displacement pipetting
Microlab® NIMBUS Personal Pipetting Workstation MICROLAB NIMBUS Microlab NIMBUS The Microlab NIMBUS is a compact, multi-channel automated liquid handler, offering speed, flexibility, ease-of-use and superior pipetting performance...at a surprisingly affordable price. NIMBUS comes available in three highly configurable open or enclosed platforms: XXNIMBUS384: 384-channel multi-pipetting head XXNIMBUS96: 96-channel multi-pipetting head (MPH) XXNIMBUS4: 1 4 independent liquid channels Who uses the Microlab NIMBUS? NIMBUS is a small-scale liquid handler designed for space and budget-conscious labs that require XXhigh pipetting accuracy and precision XXlow/medium throughput XXsm all footprint XXaffordability Where is Microlab NIMBUS used? Common industries utilizing NIMBUS include: XXDrug Discovery XXBasic & Applied Research XXBiotechnology XXDNA Forensics XXClinical Diagnostics XXEnvironmental Analysis XXAnd many others... Microlab NIMBUS ENCLOSED Extended Enclosed What is a Personal Pipetting Workstation? In today's laboratory, automation of some workflows is better served by taking a `divide and conquer' approach. In contrast to large, multi-integrated, high-end systems designed for automating complex workflows, NIMBUS is a small-footprint, leanintegrated, entry-level pipettor ideally suited for automating a single or select set of liquid handling routines. A flexible deck layout and a broad range of modular accessories and options makes reconfiguration for new applications quick and easy. What's more, an attractive price point makes NIMBUS very affordable, allowing even budget-challenged facilities to place multiple systems into a single laboratory. MICROLAB NIMBUS Why choose Microlab NIMBUS? Integrated options, intuitive software and the backing of Hamilton's renowned service and applications support makes the NIMBUS an indispensable tool for budget and spaceconstrained labs. Using proven air displacement pipetting, NIMBUS offers the same liquid handling performance as higher end systems, yet at a fraction of the price. Imagine Convenience... Microlab NIMBUS96 Microlab NIMBUS4 Some of the applications the Microlab NIMBUS can perform DNA/RNA extraction and purification PCR setup and purification Post-PCR cleanup Sequencing assays Microarray sample preparation Cloning assays Protein purification & digestion MALDI target spotting Cell assays & feeding ADMET assays Solubility assays Compound handling Sample normalization CE analysis setup Solid phase extraction Magnetic separation Liquid-liquid extraction ELISA preparation & processing Sample pooling Genomics, Proteomics & Cellomics assays 3 MICROLAB NIMBUS Family Meet the Microlab NIMBUS Family NIMBUS Extended Enclosed NIMBUS Standard Enclosed NIMBUS4 MICROLAB NIMBUS Family NIMBUS Large Extended Enclosed: for large third-party integration NIMBUS96 5 MICROLAB NIMBUS enclosed Microlab NIMBUS Enclosed The newest member of the Hamilton Robotics family, the Microlab NIMBUS Enclosed, is a high-speed platform with enhanced processing security. The instrument features a 50 µL 384-channel MPH, 1 mL 96-channel MPH for fast platebased pipetting or up to 4 independent liquid channels for flexible pipetting to and from tubes and plates. NIMBUS Enclosed uses air-displacement pipetting technology for the highest precision and accuracy, and features a locking cover set that minimizes environmental contamination. Labware Gripper Arm An optional labware gripper enables easy handling of single or stacked microplates, deep-well plates, lids, and Hamilton's Nestable Tip Racks (NTRs). The systems extended reach and 270 degrees of rotation allow for seamless handoffs to integrated devices located on- and off-deck. Extension Plate (Extended Enclosed only) A plate located on the left-hand side of the NIMBUS Extended Enclosed allows for 4 additional non-pipetable locations. The locations can use Hamilton stackers, pedestals, Hamilton Heater Shaker, and additional small third-party devices. Door Locks Doors automatically lock when the system is running Vibrating Waste Station (Not available on all system configurations) Worry free waste management removes tips and empty tip racks by gently vibrating them out of the system. Movement Indicator Provides at-a-glance cues regarding the movement status of NIMBUS, even from across the room. CO-RE Paddles Using two pipetting channels in parallel, NIMBUS can transport plates or tips across the deck without the need for a dedicated labware gripper. CO-RE Paddles are available in both 1 mL and 5 mL channel versions. MICROLAB NIMBUS enclosed 4 x Independent CO-RE Air Displacement Channels Flexible channels are available in 1000 µL or 5000 µL, enabling independent movement in both Y and Z axes, and an unprecedented pipetting range of 0.5 µL to 5000 µL Each channel features Capacitance Liquid Level Detection (cLLD) and Pressure-Based Liquid Level Detection (pLLD) to handle both polar and non-polar (organic) fluids. CO-RE® II 96 MPH A high-speed 96-channel head ensures fast and accurate pipetting to 96- or 384-well plates across a wide range of volumes, from 1 µL to 1000 µL. CO-RE II also features Capacitance-Based Liquid Level Detection (cLLD). CO-RE® II 384 MPH A highly precise, time saving 384 head, which accurately & precisely pipettes to 96, 384 and 1536 plates, in individual, column, row and whole plate formats. A volume range of 0.5 µL to 50 µL with standard feature Capacitance-Based Liquid Level Detection. Communications & Control Panel Simply connect the ethernet cable from your PC to the communications port, plug in the power cable and push the power button to bring NIMBUS to life. An Auxiliary Communications Panel is also featured to support integrated peripheral devices. Main Deck The enclosed platform allows for easy loading of pedestals, adapters, plates, tubes, and tip racks onto the high-density main deck. Choose from 3 different deck styles: XX9+ 2 9 main deck positions and 2 subdeck positions XX3x4 12 main deck positions XXShift-n-Scan 8 main deck positions and integrated tube barcode scanner (NIMBUS4 only) 7 MICROLAB NIMBUS96/384 Microlab NIMBUS96/384 The Microlab NIMBUS96/384 represents the latest in compact, high speed automated liquid handling. Using air-displacement pipetting technology for the highest precision and accuracy. Labware Gripper Arm An optional labware gripper makes for easy handling of single or stacked microplates, deepwell plates, lids and Hamilton's Nestable Tip Racks (NTRs). Extended reach and 270° of rotation allows for seamless handoffs to integrated devices located both on and off-deck. Pause/Park Buttons The park button moves the pipetting head out of the way for easier access to the deck during set-up, while the pause button allows for temporary interruption of a method mid-stream. Small Footprint NIMBUS' compact size provides for positioning on virtually any bench top as well as in select commercial hoods and bio-safety cabinets. Waste Station An attachable waste receptacle (not shown) accommodates used tips and empty NTRs. Status Indicator Provides `at-a-glance' cues to the operational status of NIMBUS. MICROLAB NIMBUS96/384 CO-RE® II 96 MPH A high-speed 96-channel head ensures fast and accurate pipetting to 96- or 384-well plates across a wide range of volumes, from 1 µL to 1000 µL. CO-RE II also features Capacitance-Based Liquid Level Detection (cLLD). CO-RE® II 384 MPH A highly precise, time saving 384 head, which accurately pipettes to 96, 384 and 1536 plates, in individual, column, row and whole plate formats. A volume range of 0.5 µL to 50 µL with standard feature Capacitance-Based Liquid Level Detection. Communications & Control Panel Simply connect the ethernet cable from your PC to the comm port, plug in the power cable and push the power button to bring NIMBUS to life. An Auxiliary Communications Panel is also featured to support integrated peripheral devices. Main Deck An open platform allows for easy loading of carrier pedestals, adapters, plates, tubes and tip racks onto the high-density main deck. Up to 5 standard microplates can be stacked into a single SBS position. Choice of 2 different deck styles: XX9+ 2 - 9 main deck positions and 2 subdeck positions XX3x4 - 12 main deck positions 9 MICROLAB NIMBUS4 Microlab NIMBUS4 The Microlab NIMBUS4 is a compact and easy-to-use automated pipetting workstation designed to meet the needs of small-scale projects and low throughput applications. Using airdisplacement pipetting technology, NIMBUS4 offers superior performance and features up to 4 independent liquid channels for flexible pipetting to/from tubes and plates. Labware Gripper Arm An optional labware gripper makes for easy handling of single or stacked microplates, deepwell plates, lids and Hamilton's Nestable Tip Racks (NTRs). Extended reach and 270° of rotation allows for seamless handoffs to integrated devices located both on and off-deck. Pause/Park Buttons The park button moves the pipetting head out of the way for easier access to the deck during set-up, while the pause button allows for temporary interruption of a method mid-stream. Small Footprint NIMBUS' compact size provides for positioning on virtually any bench top as well as in select commercial hoods and bio-safety cabinets. Waste Station An attachable waste receptacle (not shown) accommodates used tips and empty NTRs. Status Indicator Provides `at-a-glance' cues to the operational status of NIMBUS. MICROLAB NIMBUS4 4 x Independent CO-RE Liquid Channels Allowing for independent movement in both Y and Z axes, flexible channels are available in either 1000µL or 5000µL sizes for an unprecedented dynamic pipetting range from 0.5µL to 5000µL. Each channel features cLLD and pressure-based Liquid Level Detection (pLLD) to handle both polar and non-polar (organic) fluids. Communications & Control Panel Simply connect the ethernet cable from your PC to the comm port, plug in the power cable and push the power button to bring NIMBUS to life. An Auxiliary Communications Panel is also featured to support integrated peripheral devices. Main Deck An open platform allows for easy loading of carrier pedestals, adapters, plates, tubes and tip racks onto the high-density main deck. Up to 8 standard microplates can be stacked into a single position. Choice of 3 different deck styles: XX9+ 2 - 9 main deck positions and 2 subdeck positions XX3x4 - 12 main deck positions (no SubDeck) XXShift-n-Scan 8 main deck positions and integrated tube barcode scanner 11 Technology Technology Innovative technology for higher process performance and reliability. Compressed O-Ring Expansion (CO-RE) Many of today's applications require precision in tip attachment and positioning. To accomplish this, HAMILTON utilizes proprietary Compressed O-Ring Expansion (CORE) technology. CO-RE technology attaches disposable tips using a highly robust lock-and-key style mechanism. This enables a positional precision of + 0.1mm on all axes. The system requires virtually no vertical force for tip attachment or ejection, thus eliminating mechanical stress and minimizing the production of aerosols. Reduced stress also improves overall system reliability and throughput. Air Displacement Pipetting NIMBUS utilizes proven air displacement pipetting, similar to high precision handheld electronic pipettors. Benefits of this technology include: XXReduced risk of contamination or sample dilution (no system fluid) XXHigh pipetting accuracy and precision from sub-microlitre to large (>1mL) volumes XXIncreased robustness and easier maintenance owing to lack of system liquids, diluters, valves or complicated tubing Plunger Air Tip Anti-Droplet Control (ADC) This technology serves to compensate in real time for pressure changes in the liquid channels caused by high vapor pressure of volatile solvents. Upon activation, ADC prevents inadvertent dripping from the channels, reducing the risk of contaminating the deck. (NIMBUS4 only) Pressure Sleeve O-Ring Stop Tip O-Ring Groove Coupling Shoulder Liquid Level Detection (LLD) NIMBUS uses LLD technology to determine liquid levels in tubes and plates located on the pipetting deck. There are two modes of LLD: capacitative LLD (c-LLD), used to detect most types of liquids in most types of vessels; and pressure-based LLD (p-LLD), which can detect virtually all fluid types, including foaming liquids and non-conductive organic solvents. cLLD is available on all Hamilton Robotic Systems, NIMBUS384 (MPH channels A5 & P20), NIMBUS96 (MPH channels A1, B2, G11 & H12) and NIMBUS4 (pLLD is available on NIMBUS4 only). For even greater confidence in LLD, a dual mode LLD approach may be used (NIMBUS4 only). Monitored Air Displacement (MAD) By monitoring the air-based pipetting action, NIMBUS can detect clots or empty wells during the aspiration step in real time. It can also be used to pipette highly volatile solvents (NIMBUS4 only). Technology Total Aspiration and Dispense Monitoring (TADM) During crucial sample transfers (e.g. in vitro Diagnostics or DNA Forensics), parameters may be set to monitor, in real time, both the aspiration and dispense steps. TADM verifies with a traceable digital audit trail that a sample has been successfully transferred (NIMBUS4 only). 13 Software Software Hamilton's Microlab INSTINCT software provides an intuitive graphical user interface for simplified instrument control and streamlined method programming, allowing you to achieve results faster and with less training than ever before. Hamilton recognizes the critical role that instrument control software plays in overall system usability and end-user satisfaction. INSTINCT Software INSTINCT features several tools to enhance the end-user experience: XXLabware Library a comprehensive menu of commercially available microplates, deep well plates, reagent troughs/tubs as well as the complete line of Hamilton's CO-RE disposable tips XXFa vorites Tool - enables quick selection of your most commonly-used labware XXLiquid Class Tuner an easy to use utility for selecting optimal pipetting parameters and improved liquid handling performance XX3-D Viewing an intuitive tool for visualizing deck layouts SMART PIPETTING Combining these preferences together with other user-defined input (e.g. pipetting volume), INSTINCT's built-in intelligence provides: XXAutomated deck layouts auto-populates the pipetting deck with carriers, microplates/tubes and tips, making setup of deck layouts a snap XXAutomated tip tracking tracks tip usage, location and status of tip racks XXSmart plate movements auto-transporting of labware to destination or waste locations Basic Tasks For basic tasks, INSTINCT software features a series of dedicated Wizards available for commonly performed pipetting routines, each guiding you step-by-step towards final method creation. XXSerial Dilutions XXReagent Additions XXPlate Replications XXTu be to Plate XXPCR set-up XXSPE XXAnd many more... ADVANCED PROGRAMMING For the most sophisticated methods, powerful VENUS software is also featured as standard, providing the flexibility to create or modify a complex method from scratch, ensuring that your requirements are never compromised. VENUS also features a range of utilities for: XXWorklist importing/exporting XXError handling and recovery XXLIMS adaptation XXDatabase/server controls XXScheduling XXIntegrated third party device control Progress Bar Graphical status of pipetting volumes Step-wise view of protocol Plate processing order 21 CFR Part 11 Regulatory Tools VENUS software contains the software tools required to use NIMBUS in compliance with CFR 21 part 11. The tools provide audit trails, user group defined security functionality and file fidelity with the checksum system. Software Connection Status Indicator Graphical display of dispense patterns Favorite labware menu Top-down view of deck layout Undo/Redo function XXIn tuitive graphical user interface XXD esigned for users in busy labs from beginner to advanced 15 Integrated Options Integrated Options Labware Gripper ARM The NIMBUS Labware Gripper Arm option makes for quick and easy handling of single or stacked microplates, deepwell plates, lids and HAMILTON's Nestable Tip Racks (NTRs). Extended reach and 270° of rotation allows for seamless handoffs to integrated devices located both on and off-deck. 1D bc scanner Reads 1D barcodes microplates presented by Labware Gripper or CO-RE Paddles. Shift-n-Scan Tube Barcode Scanner (NIMBUS4 only) On-deck module for rapid reading of 1D barcoded tubes; accommodates wide variety of tube sizes; compatible with all major symbologies. NIMBUS Vacuum Station (NVS) Fully software-integrated vacuum system with adjustable pressure control; allows automation of SPE and other vacuum based applications. Integrated options HAMILTON Heater Shaker 2 (HHS2) Hamilton's latest heater/shaker device offers efficient on-deck orbital shaking and heating (up to 100° C). Accomodates a variety of popular standard and deep well microplates. Plate Tilt module An integrated module that lifts plates at an angle to remove liquid out of flat bottomed plates. Fill Module A liquid filling module used for large volumes of liquid needed on the deck. The module comes standard with a Liquid Sensing Sensor and easily replaced tubing. Plate Readers, Washers and other 3rd party devices A wide variety of 3rd party peripheral devices are also available for integration. 17 Accessories Labware Handling: CO-RE Paddles (NIMBUS4 only) CO-RE grippers are a cost-effective means for the on-deck transport of labware. Using two pipetting channels in parallel, NIMBUS4 can transport plates or tips (NTRs only) across the deck without the need for a dedicated Labware Gripper. For transfers to off-deck locations and devices, the Labware Gripper option is required. CO-RE Grippers are available in both 1 mL and 5 mL channel versions. Labware Pedestals : NTR Pedestal holds 1 - 4 x Nestable Tip Racks (NTRs); also used for Small Tube Adapters MTP Pedestal holds 1 x standard SBS microtiter plate DWP Pedestal holds 1 x standard SBS deep well plate; also used for PCR Tray FTR Pedestal holds 1 x Framed Tip Rack of CO-RE disposable tips; also used for Filtered CO-RE tips MTP Labware Gripper & Paddle Stacking Pedestals holds a stack of up to 5 x standard SBS microtiter plates; used with LabWare Gripper only Reagent Trough Pedestal holds up to 5 x 50 mL reagent troughs 12x75 - 13x100 mm 32 Tube Position Pedestal holds 32 x small sample tubes in one SBS position; accommodates the following tube sizes (diameter x height): XX12 mm x 75 mm; 12 mm x 100 mm; 13 mm x 75 mm; 13 mm x 100 mm Tip Isolator Pedestal available for 50, 300 and 1000 µL tips with an integrated deep well plate. The pedestal prevents cross contamination between re-used tips 1536 Plate Pedestal accomodates most commercially available 1536 MTP plates Accessories 16x75 - 17x100 mm & 15 mL Falcon Type 24 Tube Position holds 24 x medium sample tubes; accommodates the following tube sizes (diameter x height): XX16 mm x 75 mm; 16 mm x 100 mm; 17 mm x 75 mm; 17 mm x 100 mm 50 mL Falcon Like Tubes 6 Position holds 6 x 50 mL (i.e. Falcon brand) tubes; accommodates the following tube sizes (diameter x height) Labware Adapters: 96 PCR Tray Adapter accommodates most commercially available skirted, semi-skirted and unskirted 96-well PCR trays 384 PCR Tray Adapter accommodates most commercially available skirted, semi-skirted and unskirted 384-well PCR trays CO-RE Tip Adapter holds 96 x CO-RE tips; required to access single rows/columns of all Framed CO-RE tips and 10 µL NTR tips Small Tube Adapter holds up to 32 x standard volume (approx 1.7 mL) `Conical' reaction tubes or 1.8 mL cryovials; a slot feature keeps snap caps out of way to allow access for the pipetting channels Multi-Tube Adapter holds up to 24 x standard volume 1.8 - 2.0 mL conical tubes or 1.8 cryovials and up to (8) 5 mL standard vial 4 Position Adapter holds up to 5 positions on the reagent trough pedestal adding up to 4 positions for 1.8 - 2.0 mL conical tubes or 1.8 cryovials Consumables: CO-RE Disposable Tips The use of superior quality tips is essential to maximizing pipetting performance of your automated liquid handling workstation. Hamilton designs and manufactures our own disposable CO-RE tips, ensuring complete control over the production process to yield only the very highest quality product. All CO-RE tips are manufactured under strict tolerances and undergo the most stringent QA inspection process in the industry. Hamilton's CO-RE disposable tips are available in 96 or 384 tip traditional frames as well as spacesaving, stackable 96 tip Nestable Tip Racks (NTRs). CO-RE tips are available in 10, 50, 300, 1000 and 5000 µL volumes, black conductive or clear, filtered or unfiltered, `clean' (nuclease and pyrogen-free) or sterile. 19 Specifications: NIMBUS96/384 Enclosed NIMBUS96/384 Enclosed Functional & Performance Specifications: Parameter Specification Input Power (Primary) Universal Supply: Output Power (Secondary) Power: Wattage: Power supply Physical Dimensions (1000 µL) | Operating Dimensions Length: Width: Height: 100 - 240 VAC, 50-60 Hz, 5 A +42 VDC +5% 600 Watts maximum UL/CSA/CE approved universal power supply with IEC connection 53.5 in. (135.9 cm) 27.9 in. (70.9 cm) 35.0 in. max (88.9 cm) With Large Extended Enclosed Physical Dimensions Length: Width: Height: 65.5 in. (166.1 cm) 27.5 in. (70.9 cm) 35.0 in. max (88.9 cm) Weight: Weight with Large Extended Enclosed: 223 lbs (101.2 kg) approx. 243 lbs (110.2 kg) approx. Pipetting specifications for disposable tips - 96 channel CO-RE head Disposable tip size: 10 µL: 10 µL: 10 µL: 50 µL: 50 µL: 50 µL: 300 µL: 300 µL: 300 µL: Test environment & equipment available upon request 1000 µL: Volume 1 µL 5 µL 10 µL 1 µL 5 µL 50 µL 10 µL 100 µL 300 µL 1000 µL Accuracy |R| (%) 5.0% 2.5% 1.5% 5.0% 2.5% 1.5% 3.0% 1.5% 1.0% 1.0% Pipetting specifications for disposable tips - 50 L CO-RE 384-Probe Head Disposable tip size: Volume Test environment & equipment available upon request 50 µL: 50 µL: 50 µL: 50 µL: 50 µL: 50 µL: 50 µL: 50 µL: 50 µL: 0.1 µL 0.5 µL 1 µL 1 µL 5 µL 5 µL 10 µL 10 µL 50 µL Precision CV (%) 8.0% 6.0% 3.5% 15.0% 3.0% 4.0% 2.0% 3.0% 2.0% Pipetting specifications for disposable tips - Using the 50 L CO-RE 384-Probe Head as a 96-Probe Head Disposable tip size: Volume Test environment & equipment available upon request 300 µL Rocket: 300 µL Rocket: 300 µL Rocket: 300 µL Rocket: 300 µL Rocket: 1 µL 5 µL 10 µL 100 µL 300 µL Precision CV (%) 4.0% 2.0% 2.0% 2.0% 2.0% Liquid level detection 96 channel CO-RE head: Capacitive liquid level detection (cLLD) (Channels A1, B2, G11 and H12) Liquid level detection 384 channel CO-RE head: Capacitive liquid level detection (cLLD) (Channels A5 and P20) Deck Capacity 11 or 12 positions Communication type Ethernet Precision CV (%) 5.0% 2.0% 2.0% 5.0% 2.0% 0.75% 2.0% 2.0% 2.0% 0.75% Specification: NIMBUS96/384 Enclosed NIMBUS96/384 Enclosed Functional & Performance Specifications (continued): Parameter Operating Temperature: Relative Humidity: Altitude: Storage Temperature: CSA Certification Installation category: Pollution degree: Specification 15o to 35oC (59o to 95oF) 30% to 85% R.H. non-condensing 2000 m (1.2 miles) above sea level -20oC (-4.0oF) @ 10% humidity to 70oC (158oF) @ 90% humidity non-condensing II 2 NIMBUS96/384 Enclosed Labware Gripper Specifications: Parameter Plate format Absolute positioning Gripping force Transport mass Operating Data Specification microtiter footprint plate height < 43 mm accuracy X, Y, Z = 0.5 mm reproducibility X, Y, Z = 0.25 5 N 16 N (default 9 N): Labware Gripper Landscape 190220 300g filled deep-well plate Temperature range Relative humidity Altitude 15°C 35°C 30% 85% (non-condensing, indoors) 2000 m above sea level NIMBUS96/384 Enclosed Dimensions with Extended Enclosed Shown Large Extended Enclosed Height: 35.0" (88.9 cm) Length: 65.5" (166.4 cm) Width: 27.9" (70.9 cm) Weight: 243 lbs (110.2 kg) approx. 21 Specifications: NIMBUS4 Enclosed NIMBUS4 Enclosed Functional & Performance Specifications: Parameter Input Power (Primary) Universal Supply: Output Power (Secondary) Power: Wattage: Power supply Physical Dimensions / Operating Dimensions Length: Width: Height: With Extended Enclosed Physical Dimensions Length: Width: Height: With Large Extended Enclosed Physical Dimensions Length: Width: Height: Weight: Weight with Extended Enclosed: Weight with Large Extended Enclosed: Pipetting specifications for disposable tips Disposable tip size: Test environment & equipment available upon request Liquid level detection Independent Channels: Deck Capacity Communication type Operating Temperature: Relative Humidity: Altitude: Storage Temperature: CSA Certification Installation category: Pollution degree: Plate format Specification 100 - 240 VAC, 50-60 Hz, 5A +42 VDC +5% 600 Watts maximum UL/CSA/CE approved universal power supply with IEC connection 41.2 in. (104.6 cm) 27.9 in. (70.9 cm) 32.7 in. max (83.1 cm) 53.5 in. (135.9 cm) 27.9 in. (70.9 cm) 35.0 in. max (88.9 cm) 65.5 in. (166.1 cm) 27.9 in. (70.9 cm) 35.0 in. max (88.9 cm) 203 lbs (92.1 kg) approx. 223 lbs (101.2 kg) approx. 243 lbs (110.2 kg) approx. Volume 10 µL: 10 µL: 10 µL: 50 µL: 50 µL: 50 µL: 300 µL: 300 µL: 300 µL: 1000 µL: 1000 µL: 1000 µL: 1 µL 5 µL 10 µL 1 µL 5 µL 50 µL 10 µL 50 µL 300 µL 10 µL 100 µL 1000 µL Accuracy |R| (%) 5.0% 2.5% 1.5% 5.0% 2.5% 1.5% 3.0% 1.5% 1.0% 7.5% 2.0% 1.0% Precision CV (%) 5.0% 2.0% 1.5% 5.0% 2.0% 1.0% 2.0% 1.0% 1.0% 3.5% 1.0% 1.0% For pipetting of less than 10 µL HAMILTON recommends 10 µL/50 µL volume disposable tips to achieve highest pipetting precision. Capacitive liquid level detection (cLLD) (Pressure liquid level detection (pLLD) 8-12 positions Ethernet 15o to 35oC (59o to 95oF) 30% to 85% R.H. non-condensing 2000 m (1.2 miles) above sea level -20oC (-4.0oF) @ 10% humidity to 70oC (158oF) @ 90% humidity non-condensing II 2 microtiter footprint plate height < 43 mm Specifications: NIMBUS4 Enclosed NIMBUS4 Enclosed Labware Gripper Specifications: Parameter Plate format Absolute positioning Gripping force Transport mass Operating Data Specification microtiter footprint plate height < 43 mm accuracy X, Y, Z = 0.5 mm reproducibility X, Y, Z = 0.25 5 N 16 N (default 9 N): Independent Channels Gripper Landscape 190220 300g filled deep-well plate Temperature range Relative humidity Altitude 15°C 35°C 30% 85% (non-condensing, indoors) 2000 m above sea level NIMBUS4 Enclosed Dimensions with Standard Extended Enclosed Shown Standard Extended Enclosed Large Extended Enclosed Height: 32.7" (83.1 cm) Length: 41.2" (104.6 cm) Height: 35.0" (88.9 cm) Length: 65.5" (166.3 cm) Width: 27.9" (70.9 cm) Weight: 203 lbs approx. (92.1 kg) Width: 27.9" (70.9 cm) Weight: 243 lbs (110.2 kg) approx. 23 Specifications: NIMBUS96 NIMBUS96 Functional & Performance Specifications: Parameter Specification Input Power (Primary) Universal Supply: 100 - 240 VAC, 50-60 Hz, 5 A Output Power (Secondary) Power: Wattage: +42 VDC +5% 600 Watts maximum Power supply UL/CSA/CE approved universal power supply with IEC connection Physical Dimensions (1000µL) Length: Width: Height: Operating Dimensions Width: (FRONT to REAR) Length: (LEFT to RIGHT) Height: Weight: 37.4 in. (94.9 cm) 20.1 in. (51.1 cm) 30.6 in. max (77.7 cm) 20.1 in. (51.1 cm) 51.8 in. (131.6 cm) 30.6 in. max (77.7 cm) 145 lbs (65.8 kg), 1000µL Pipetting specifications for disposable tips - 96 channel CO-RE head Disposable tip size: 10 µL: 10 µL: 10 µL: 50 µL: 50 µL: 50 µL: 300 µL: 300 µL: 300 µL: Test environment & equipment available upon request 1000 µL: Volume 1 µL 5 µL 10 µL 1 µL 5 µL 50 µL 10 µL 100 µL 300 µL 1000 µL Accuracy |R| (%) 5.0% 2.5% 1.5% 5.0% 2.5% 1.5% 3.0% 1.5% 1.0% 1.0% Precision CV (%) 5.0% 2.0% 2.0% 5.0% 2.0% 0.75% 2.0% 2.0% 2.0% 0.75% Liquid level detection 96 channel CO-RE head: Capacitive liquid level detection (cLLD) (Channels A1, B2, G11 and H12) Deck Capacity 8-12 positions Communication type Ethernet Operating Temperature: Relative Humidity: Altitude: 15o to 35oC (59o to 95oF) 30% to 85% R.H. non-condensing 2000 m (1.2 miles) above sea level Storage Temperature: -20oC (-4.0oF) @ 10% humidity to 70oC (158oF) @ 90% humidity non-condensing CSA Certification Installation category: II Pollution degree: 2 Specification: NIMBUS96 NIMBUS96 Labware Gripper Specifications: Parameter Plate format Absolute positioning Gripping force Transport mass Operating Data Specification microtiter footprint plate height < 43 mm accuracy X, Y, Z = 0.5 mm reproducibility X, Y, Z = 0.25 5 N 16 N (default 9 N): Labware Gripper Landscape 190220 300g filled deep-well plate Temperature range Relative humidity Altitude 15°C 35°C 30% 85% (non-condensing, indoors) 2000 m above sea level NIMBUS96 Dimensions 25 Specifications: NIMBUS4 NIMBUS4 Functional & Performance Specifications: Parameter Input Power (Primary) Universal Supply: Output Power (Secondary) Power: Wattage: Power supply Physical Dimensions Length: Width: Height: Operating Dimensions Width: (FRONT to REAR) Length: (LEFT to RIGHT) Height: Weight: Pipetting specifications for disposable tips Disposable tip size: Test environment & equipment available upon request Liquid level detection Independent Channels: Throughput Independent Channels: Deck Capacity Communication type Operating Temperature: Relative Humidity: Altitude: Storage Temperature: CSA Certification Installation category: Pollution degree: Plate format Specification 100 - 240 VAC, 50-60 Hz, 5A +42 VDC +5% 600 Watts maximum UL/CSA/CE approved universal power supply with IEC connection 37.4 in. (95 cm) 20.1 in. (51.1 cm) 30.3 in. max (77.0 cm) 20.1 in. (51.1 cm) 49.0 in. (124.5 cm) 30.3 in. max (77.0 cm) 145 lbs (65.8 kg) Volume 10 µL: 10 µL: 10 µL: 50 µL: 50 µL: 50 µL: 300 µL: 300 µL: 300 µL: 1000 µL: 1000 µL: 1000 µL: 1 µL 5 µL 10 µL 1 µL 5 µL 50 µL 10 µL 50 µL 300 µL 10 µL 100 µL 1000 µL Accuracy |R| (%) 5.0% 2.5% 1.5% 5.0% 2.5% 1.5% 3.0% 1.5% 1.0% 7.5% 2.0% 1.0% Precision CV (%) 5.0% 2.0% 1.5% 5.0% 2.0% 1.0% 2.0% 1.0% 1.0% 3.5% 1.0% 1.0% For pipetting of less than 10µL HAMILTON recommends 10µL/50µL volume disposable tips to achieve highest pipetting precision. Capacitive liquid level detection (cLLD) (Pressure liquid level detection (pLLD) Replication of one 96-well plate, with cLLD on aspiration: 35s (incl. new tips) Reformatting of four 96-well plates to one 384-well plate, 50 µL, new tips, with cLLD on aspiration: 140s 8-12 positions Ethernet 15o to 35oC (59o to 95oF) 30% to 85% R.H. non-condensing 2000 m (1.2 miles) above sea level -20oC (-4.0oF) @ 10% humidity to 70oC (158oF) @ 90% humidity non-condensing II 2 microtiter footprint plate height < 43 mm Specifications: NIMBUS4 NIMBUS4 Labware Gripper Specifications: Parameter Plate format Absolute positioning Gripping force Transport mass Operating Data Specification microtiter footprint plate height < 43 mm accuracy X, Y, Z = 0.5 mm reproducibility X, Y, Z = 0.25 5 N 16 N (default 9 N): Independent Channels Gripper Landscape 190220 300g filled deep-well plate Temperature range Relative humidity Altitude 15°C 35°C 30% 85% (non-condensing, indoors) 2000 m above sea level NIMBUS4 Dimensions 27 Hamilton Company is focused on blending innovation and accuracy to deliver customers unparalleled products. © 2014 Hamilton Company. All rights reserved. All trademarks are owned and/or registered by Hamilton Company in the U.S. and/or other countries. Version 1. Lit. No. BR0001-- 06/2014 QTY: X,XXX Printed in U.S.A. Web: www.hamiltonrobotics.com USA: 800-648-5950 Email: infoservice@hamiltonrobotics.com United States Tel: +1-775-858-3000 United Kingdom & Ireland Tel: +44 (0)121-717-0199 Brazil Tel: +55 (11) 9677-4093 China Tel: +86-21-6164-6567 France Tel: +33 (01) 69751616 Italy Tel: +39-39-689-33-93 Denmark, Norway, Sweden, Finland Tel: +45-70-26-4499 Germany, Switzerland, Austria, Benelux Tel: +49 (089) 552649-0 To find a subsidiary or distributor in your area, please visit hamiltonrobotics.com/contacts.Adobe PDF Library 10.0.1 Adobe InDesign CS6 (Windows)
![]() |
Hamilton PSR 74 User Manual: Features and Operation A comprehensive guide to the Hamilton PSR 74 digital watch, covering its display modes, illumination functions, time and date setting procedures, and battery status indicators. |
![]() |
Hamilton Khaki Navy Frogman Auto Chrono Instruction Manual This document provides instructions for the Hamilton Khaki Navy Frogman Auto Chrono watch, including features, recommendations for water-resistance, and how to adjust the time and date, and use the chronograph functions. |
![]() |
Hamilton Ventura Edge Dune Watch Instruction Manual A comprehensive guide to operating and maintaining the Hamilton Ventura Edge Dune watch, including time setting, illumination features, and battery indicators. |
![]() |
Hamilton Face 2 Face III Limited Edition Automatic Chronograph Watch Instructions Official instruction manual for the Hamilton Face 2 Face III Limited Edition automatic chronograph watch, detailing its pulsometer and tachymeter functions, case operation, and general usage. |
![]() |
VisiFerm™ DO Sensors Operating Instructions Comprehensive operating instructions for Hamilton's VisiFerm™ DO sensors, covering installation, configuration, operation, maintenance, and troubleshooting for accurate dissolved oxygen measurement. |
![]() |
VisiFerm™ mA Sensors: Operating Instructions and Technical Guide Comprehensive operating instructions and technical guide for Hamilton's VisiFerm™ mA optical dissolved oxygen (DO) sensors. Covers installation, configuration, operation, maintenance, and troubleshooting for industrial applications. |
![]() |
Hamilton Khaki Flight Timer Instruction Manual Comprehensive instruction manual for the Hamilton Khaki Flight Timer watch, detailing its analog and digital functions, pilot-specific features, care, maintenance, and operation. Learn about time zones, alarms, chronograph, and flight logging. |
![]() |
Hamilton Memosens pH Sensors for Process Analytics: Operating Instructions Comprehensive operating instructions for Hamilton Memosens pH sensors used in process analytics, covering specifications, installation, maintenance, safety, and ATEX guidelines for accurate pH measurement. |