Ariston Slideout Hood User Manual

Models: ARHS60X | ARHS60X-L

Hello

Congratulations on selecting this Ariston slideout rangehood. Our appliances have been specifically designed for Australian and New Zealand kitchens. Please read through this user manual carefully as it contains information that will ensure that your appliance is installed correctly, important operating & care instructions, and also some advice on what to do if this appliance is not performing as intended.

Warning & Safety Information

Installation & Ducting

Figure 1.1 shows a diagram of the rangehood with dimensions and indicates a 10A plug fitted.

Figure 1.2 illustrates the minimum height from the hob surface to the underside of the rangehood. For an electric hob, this is 600mm, and for a gas hob, it is 650mm.

Important: Before handling the rangehood during installation, it is recommended that you remove the filter to prevent damage.

Notice: If the instructions for the gas hob specify a greater distance, this has to be observed. Any installation above 750mm will compromise performance.

Ducted Option

  1. Remove the filter.
  2. Optional: Replace the 40mm front rail with the 80mm front rail (included in the box).
  3. Ensure the internal switch is in the ducted position.
  4. Determine the most efficient path for the ductwork, minimize bends, and keep the length of the ductwork to a minimum.
  5. Before fixing the range hood, drill a hole to accommodate the 120mm ducting that you have selected.
  6. It is important to run and finish (install roof/wall caps) prior to installation of the hood.
  7. Ensure that access has been allowed for the power cable and plug after installation.
  8. Remove the 120mm ducting cover plate and attach the ducting adaptor.
  9. Hold the hood up to the underside of the cabinet. Screw the rangehood to the underside of the cabinet. Ensure that you do not damage any of the wiring during installation.
  10. Attach the ducting adaptor to the ducting.
  11. Re-install filter.
  12. Plug in the power to the unit, turn on and test.

Re-Circulating Option

  1. Remove the filter.
  2. Remove the front sealing tape to expose the front vents. Do not remove the top 120mm outlet cover.
  3. Ensure the internal switch is in the recirculating position.
  4. Drill 4 fixing holes as per the drawing. Ensure that access has been allowed for the power cable and plug.
  5. Hold the hood up to the underside of the cabinet. Screw the rangehood to the underside of the cabinet. Ensure that you do not damage any of the wiring during installation.
  6. Re-install filter.
  7. Plug in the power to the unit, turn on and test.

Notice: When the rangehood is re-circulating, carbon filters should be installed.

Warning: DO NOT penetrate any screws into the range hood as this may result in electrical hazards.

Warning: Failure to install the screws or fixing device in accordance with these instructions may result in electrical hazards.

Diagrams show 'Top Ducting', 'Side Ducting', and 'Front Re-Circulating' (Carbon filter required) options.

Operating Instructions

Important: To operate the unit, ensure that the power is turned on and the front visor is fully extended. This will provide access to the light and speed controls.

Fan Speed

The LOW/OFF/HIGH switch is located on the right-hand side of the unit. This unit features 2 speed settings. A single line indicates low speed, and double lines indicate the high speed.

To turn the unit off, you can either slide the visor into the closed position or set the speed switch to the middle position (off).

Light

The On/Off switch for the light is located on the left-hand side of the unit, as indicated in the diagram.

Diagram shows controls for 'LIGHT' and 'LOW/OFF/HIGH' fan speed.

Maintaining Your Rangehood

General Maintenance

Ensure that the power to the unit is switched off prior to cleaning. The surface should only be cleaned with warm soapy water and a soft non-abrasive cloth. In coastal environments and humid areas, more frequent cleaning is required to maintain the finish.

Filters

This unit is supplied with Aluminium filters designed for ducted installations. Aluminium filters are dishwasher safe or can be cleaned with hot soapy water. Ensure that filters are thoroughly dry before re-installing.

You may want to order charcoal filters designed to eliminate odours from the exhaust fumes when installing the appliance for recirculating mode. These filters cannot be cleaned and should be replaced every 3-6 months depending on use.

Lamps

Your range hood is fitted with one of the following two different types of lamps accordingly to its model:

Product Specification

600 SLIDEOUT HOOD

Model: ARHS60X
Model: ARHS60X-L

For service please call:

Symbols indicate compliance with CE standards and electrical safety.

Proof of Purchase

Attach your proof of purchase here for future reference.

Notes

Space for user notes.

Contact Details

AUSTRALIA

ARISIT PTY LIMITED
40-44 Mark Anthony Drive
Dandenong South, VIC 3175
Australia
Ph: 1300 815 589
FX: (03) 9768 0838
consumer.care@arisit.com

NEW ZEALAND

ARISIT PTY LIMITED
PO Box 68-140
Newton, Auckland 1145
New Zealand
Ph: (09) 306 1020
FX: (09) 302 0077
sales@aristonappliances.co.nz

Ariston is committed to ongoing research and development. Every effort has been made to ensure all information in this user manual is correct at the time of going to print. Dimensions should be used as a reference only, and actual dimensions should be taken from the physical product only. The manufacturer reserves the right to change specifications without notice.

PDF preview unavailable. Download the PDF instead.

ARHS60X-L-UM v3.1.compressed Adobe Illustrator CC 2015 (Macintosh) 3-Heights(TM) PDF Optimization Shell 4.8.25.2 (http://www -tools.com)

Related Documents

Preview Ariston ARU52AX-L 52cm Undermount Rangehood: Features, Specifications, and Dimensions
Detailed information on the Ariston ARU52AX-L 52cm Undermount Rangehood, including its key features, technical specifications, dimensions, and warranty information.
Preview Ariston Velis Dry Electric Water Heater: Installation, Use, and Maintenance Guide
Comprehensive guide for the Ariston Velis Dry electric water heater, covering installation, usage, maintenance, safety instructions, and troubleshooting. Available in multiple languages.
Preview Ariston AGITUM520 52cm Undermount Rangehood - Specifications and Features
Detailed specifications and features of the Ariston AGITUM520 52cm Undermount Rangehood, including extraction power, noise levels, dimensions, and warranty.
Preview Ariston Electric Water Heaters User Manual
Comprehensive user manual for Ariston electric water heaters, covering installation, operation, maintenance, and safety guidelines. Includes technical specifications and warranty information.
Preview Manuale Ariston ARI VERT 200 V 2.2K: Installazione e Uso Scaldacqua Elettrico
Guida completa all'installazione, uso e manutenzione dello scaldacqua elettrico Ariston ARI VERT 200 V 2.2K (modello 3000375), con istruzioni di sicurezza e specifiche tecniche.
Preview Ariston ARMF 125 Washer-Dryer User Manual: Installation, Operation, and Maintenance
Comprehensive user manual for the Ariston ARMF 125 washer-dryer, covering installation, operation, wash cycles, personalization, detergents, precautions, care and maintenance, troubleshooting, and service information.
Preview Ariston Electric Water Heaters: Installation and Operation Manual
Comprehensive guide for the installation and operation of Ariston electric water heaters, covering safety instructions, technical specifications, installation procedures, maintenance, and troubleshooting.
Preview Ariston Electric Water Heater User Manual
Comprehensive user manual for Ariston electric water heaters, covering installation, operation, maintenance, and safety guidelines. Includes technical specifications and warranty information.