Eaton 107631
Product Specifications
General Specifications
Product Name | Eaton Moeller series NZM - Molded Case Circuit Breaker |
Catalog Number | 107631 |
Model Code | NZMN2-AF15-BT-NA |
EAN | 4015081072972 |
Product Length/Depth | 149 mm |
Product Height | 195 mm |
Product Width | 105 mm |
Product Weight | 2.345 kg |
Compliances | RoHS conform |
Certifications
IEC 60947-2 UL 489 CE marking UL listed CSA-C22.2 No. 5-09 UL (Category Control Number DIVQ) UL (File No. E31593) CSA (Class No. 1432-01) Specially designed for North America IEC CSA (File No. 22086) CSA certified IEC/EN 60947 UL/CSA
Product Specifications
For specified heat dissipation (In): 15 A
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 690 V, 50/60 Hz: 5 kA
Meets the product standard's requirements.
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
- DIN rail (top hat rail) mounting optional
- Built-in device fixed built-in technique
- Fixed
15 A
Does not apply, since the entire switchgear needs to be evaluated.
- Max. 10 segments of 16 mm x 0.8 mm at rear-side connection (punched)
- Max. 10 segments of 16 mm x 0.8 mm at box terminal
- Min. 2 segments of 16 mm x 0.8 mm at rear-side connection (punched)
- Min. 2 segments of 9 mm x 0.8 mm at box terminal
Rocker lever
Meets the product standard's requirements.
40 °C
Finger and back-of-hand proof to DIN EN 50274/VDE 0106 part 110
- M8 at rear-side screw connection
- Min. 16 mm x 5 mm direct at switch rear-side connection
- Max. 20 mm x 5 mm direct at switch rear-side connection
Is the panel builder's responsibility.
- Maximum back-up fuse, if the expected short-circuit currents at the installation location exceed the switching capacity of the circuit breaker (Rated short-circuit breaking capacity Icn)
- Rated current = rated uninterrupted current: 15 A
- Switches conform to UL/CSA as well as the IEC regulations. IEC switching performance values are contained on the rating plate.
- Fixed overload releases Ir
70 °C
Front side
- Damp heat, constant, to IEC 60068-2-78
- Damp heat, cyclic, to IEC 60068-2-30
- 4 mm² - 3/0 mm² (1x) direct at switch rear-side connection
- 4 mm² - 350 mm² (1x) at box terminal
- 4 mm² - 350 mm² (1x) at tunnel terminal
- Motor drive optional
- Protection unit
355 A gG/gL
- 6500 operations at 400 V AC-3
- 7500 operations at 690 V AC-1
- 6500 operations at 415 V AC-3
- 10000 operations at 400 V AC-1
- 5000 operations at 690 V AC-3
Frame clamp
< 10 ms
8000 V
50 kA
Is the panel builder's responsibility.
A (IEC/EN 60947-2)
Three-pole
-25 °C
Does not apply, since the entire switchgear needs to be evaluated.
Does not apply, since the entire switchgear needs to be evaluated.
- 14 mm² - 18 mm² (1x)
- 16 mm² - 18 mm² (2x)
2.87 W
350 A
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Does not apply, since the entire switchgear needs to be evaluated.
Is the panel builder's responsibility.
- 300 A (380/400 V AC-1, making and breaking capacity)
- 300 A (415 V AC-1, making and breaking capacity)
- 15 A (660-690 V AC-3, making and breaking capacity)
- 15 A (690 V AC -1, making and breaking capacity)
85 kA
- Branch circuits, feeder circuits
- Use in unearthed supply systems at 690 V
Does not apply, since the entire switchgear needs to be evaluated.
187 kA
35 kA
- IP40 (with insulating surround)
- IP66 (with door coupling rotary handle)
53 kA
40 kA
350 A
15 A
0 A
0
Meets the product standard's requirements.
Meets the product standard's requirements.
20000 operations
15 A
690 V - 690 V
- 6 mm² - 11 mm² (1x) direct at switch rear-side connection
- 6 mm² - 12 mm² (1x) at box terminal
- 16 mm² (1x) at tunnel terminal
- IP00 (terminations, phase isolator and strip terminal)
- IP10 (tunnel terminal)
600Y/347 V, 480 V
Is the panel builder's responsibility.
350 A
- IP20 (basic degree of protection, in the operating controls area)
- IP20
III
1.9 kA
0 A
6000 V
0
1.9 kA
70 °C
Thermomagnetic release
25 kA
3
Is the panel builder's responsibility.
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
- System and cable protection
- Current limiting circuit breaker
350 A
105 kA
Box terminal
Circuit breaker
Meets the product standard's requirements.
Meets the product standard's requirements.
Meets the product standard's requirements.
74 kA
0
- 500 V AC (between auxiliary contacts and main contacts)
- 300 V AC (between the auxiliary contacts)
120
NZM2
As required
20 g (half-sinusoidal shock 20 ms)
1000 V
16 mm² (1x) at tunnel terminal
Resources
Brochures
- eaton-feerum-the-whole-grain-solution-success-story-en-us.pdf
- eaton-digital-nzm-brochure-br013003en-en-us.pdf
Catalogs
Certification Reports
Drawings
- eaton-circuit-breaker-switch-nzm-mccb-dimensions-017.eps
- 123X312
- 123X341
- eaton-circuit-breaker-nzm-mccb-dimensions-019.eps
- eaton-circuit-breaker-switch-nzm-mccb-3d-drawing.eps
- 123I247