Guardian Ductless Heat Pumps

Template PowerPoint HITACHI

More sequence description is listed in the manual. 1. Does the system communicate with WiFi? Yes, you will use the manufacturers Smart Thermostats WiFi app ...

3 giorni fa — This guide is intended to illustrate how to pair our single-phase Guardian (R454B) Outdoor Unit (ODU) and. JHE Mult-position AHU to the Honeywell HZ432 TrueZone ...

PDF preview unavailable. Download the PDF instead.

guardian zoning control application guide 1
Zone Control Application for Guardian (R454B)
DFS zoning application: This guide is intended to illustrate how to pair our single-phase Guardian (R454B) Outdoor Unit (ODU) and JHE Mult-position AHU to the Honeywell HZ432 TrueZone control panel. Further described in the guide, are the requirements for a successful implementation and completion of a zoned system. The system selected will depend on the entire load calculation required for all the zones.

Zone Layout System Equipment Zoning Wiring Diagrams HZ432 Configuration Setup

Mechanical Layout Parts List Performance FAQ's

Back

Zone Layout
Back

Example below: Shows a typical layout of the zones within a residential home.
Back

System Equipment
Back

Guardian(R454B) Equipment:
Guardian single phase 208/230V HP Heat Pump Units, 24k to 48k Outdoor Unit

JHE Multi-Position Air Handler

Unit Models:
UPC24CN23STG1, UPC36CN23STG1,
UPC48CN23STG1
Back

Unit Models: JHE18B5AB2SS1, JHE24B5AC2SS1, JHE36B5CD2SS1, JHE48C5CG2SS1

Zone Control Equipment:

Back

Honeywell HZ432 TrueZone

Zone Controller

Zoning System Zone Damper Models (Honeywell):

ZD Series Zone Damper Spring-Open Power-Closed
Back

RRD Series Zone Damper Power-Open Power Closed

ARD Series Zone Damper Spring-Open Power-Closed

Zoning System Bypass Damper Model (Honeywell):
SPRD Series Barometric by-pass damper (Static Pressure Control)
Back

Zoning Wiring Diagrams
Back

5-wire thermostat installation example:
Connect thermostat to zone panel. To connect wire to the panel, strip approximately 1/4 in. of insulation and push wire into terminal. To release wire, press the button on top of the terminal. Note: Install thermostats using instructions provided with the 5-wire thermostat.
Back

ARD or ZD Series Damper wiring example:
Back

RRD or MARD Series Dsamper wiring example:
Back

Zoning System example 4-zones:

5-Wire Smart Thermostats mounted in Spaces to be controlled.

Back

Outdoor unit connected to AHU indoor unit (24k/36k/48k)
Outdoor unit connected to AHU indoor unit (24k/36k/48k)
Back

HZ432 Configuration Setup
Back

HZ432 Panel Configuration Set Up
VRF Zoning Configuration Menu System Type = Conventional Cool Stages=1 Heat Stages=1 RF Enabled=No Zones Installed= 1 thru 4 (Select how many zones are needed) Advanced Configuration=Yes Heat Fan Control=HVAC Purge Time (2) 2,3.5,5 minutes Fan in Purge=HVAC Purge Damper=Unchanged Change over Delay=(15) 15,20,30 minutes Discharge sensor=No LCD Contrast=4 (Adjustable 1 thru 10) Save Changes=Yes Purge override=(Next =Yes) Normal Mode Note: See HZ432 Zone Panel Professional Installation Guide for more details.
Back

Mechanical Layout
Back

AHU Mechanical layout example:
OR HZ432
AHU Back

Parts List
Back

Parts list:

Equipment Guardian (R454B)
Honeywell 5-Wire Smart Thermostat

ODU Models
UPC24CN23STG1 UPC36CN23STG1 UPC48CN23STG1

AHU Models

Zone Controller- Zone Controller Expansion-

4 zones

Additional 4 zones

JHE18B5AB2SS1 JHE24B5AC2SS1 JHE36B5CD2SS1 JHE48C5CG2SS1

Zone Dampers

A2L Mitigation

Bypass Damper 5-Wire Thermostst

System

Built in JHE AHU

SPRD series damper

HZ432 TrueZone Taz-4 Add-A-Zone Control ARD/ZD series damper Barometric by-pass

Control Panel

Panel

RRD/MARD series damper

damper

Compatible with any Conventional /
SMART 5-wire thermostat in the
market

Back

Performance
Back

Performance:
Back

FAQ's
Back

1.
FAQ's 1. 1. 1.
1. 1. 1. 1.
1. 1.

What is the system voltage for the systems? For the ODU 208/230 vac supply and IDU they use 115/vac/ 208/230 vac supply.
Can you source the supply voltage from the ODU? Yes, you can source from the ODU if the IDU has the same input voltage. Need to verify circuit breaker size to accommodate the additional load of the IDU. Otherwise, a separate circuit is required to power IDU.
Where does the Zone controller get its supply power from? From the IDU (AHU). This will power the HZ432 TrueZone panel which will supply the 24vac to the connected 5-wire thermostats, dampers.
What is the zoning size of the system? The minimum requirement is 2 zones, but with expansion panel can go to 8 zones. The Honeywell HZ432 TrueZone Panel has 4 zones. If more zones are required, add the expansion TAZ-4 Add-A-Zone panel for 4 additional zones. Note: Engineer / installer must make the load calculation for the system for all the zones. The possibility of all the zones requiring Heat or Cool must be met by the system designed. Is there any setup of the Controls? Yes, there are two Items to be setup. The HZ432 and the C3STAT01 adapter. See HZ432 Configuration Setup. For additional information, refer to the specific Product documents that come with the units.
Who sets up the Bypass damper? The SPRD Series Bypass damper is a mechanical damper. A trained professional (air Balancer) should set the damper to the correct required static pressure setting to maintain the required static pressure of the system.
Can you Twin the ODU's for more capacity? No, they are intended to be 1 to 1 with the ODU / IDU chosen for the required load.
Does the system have to be set to heat or Cool mode? The HZ432 sets the system mode based on any one of the connected thermostats. The zone that calls for Heat or Cool, puts the system in that mode. Example: Zone 1 call for the zone to be in heating. Zone 1 damper is open, and the ODU is set to heat. The other zones that are not requiring heat, their dampers will close. Providing heat to that one zone. If there is a call from another zone for cooling after it is in heat mode. The HZ432, will wait until the 1st zone is satisfied and shuts off, then the system will switch to the zone requiring cooling. If the system does not satisfy the active zone within the Changeover time (adjustable) the ZN432 will switch to the other mode to satisfy those zones. More sequence description is listed in the manual.
Does the system communicate with WiFi? Yes, you will use the manufacturers Smart Thermostats WiFi app to control via your Smart phone.
Can you use any manufacturers damper kit. Yes, but you must not exceed 8 va power of the 24vac actuation, Use the preferred Honeywell damper kits.

Back

Note: Systems must be installed by qualified technician.