SANELA SLP 02K / SLP 02KZ Urinal Flush Valve
Model Numbers: SLP 02K (Code Nr. 01022), SLP 02KZ (Code Nr. 01023)
Brand: SANELA
Overview
This document provides mounting instructions, technical specifications, and service information for the SANELA SLP 02K and SLP 02KZ automatic urinal flush valves.
Mounting Instructions
Follow these steps for installation:
Step 1: Mounting the Bracket
Mount the provided bracket to the wall. Ensure a minimum distance of 150 mm from the top of the urinal and a minimum of 200 mm from the floor or any obstruction below.
[Diagram: Wall mounting bracket placement showing 150mm height relative to urinal and minimum 200mm clearance below.]
Step 2: Connecting the Valve to Water Supply
Connect the valve to the water supply using the G 3/4" thread. Ensure a secure connection.
[Diagram: Connecting the valve unit to the water pipe using a G 3/4" fitting.]
Step 3: Electrical Connections (SLP 02KZ)
For the SLP 02KZ model, connect the 230 V / 50 Hz power supply and the 24V DC low-voltage supply to the respective terminals on the unit.
[Diagram: Electrical connections for SLP 02KZ showing 230V/50Hz mains input and 24V DC low-voltage input.]
Step 4: Electrical Connections (SLP 02K / SLP 02KZ)
Connect the 24V DC low-voltage supply to the valve unit. Ensure correct polarity.
[Diagram: Electrical connections for SLP 02K/02KZ showing 24V DC low-voltage input.]
Step 5: Wiring
Connect the sensor, valve, and power supply according to the wiring diagram. The system operates on 24V DC.
[Diagram: Wiring schematic for sensor, valve, and 24V DC power.]
Step 6: Final Assembly
Attach the main unit to the mounted bracket and connect all necessary components.
[Diagram: Final assembly of the flush valve unit on the urinal.]
Step 7: Settings and Operation
Sensor Range: Adjustable between 0.3 - 0.7 meters.
Automatic Adjustment: The flush duration can be set between 0.15 - 15.5 seconds.
Operation Switch: Use the OFF/ON switch to control the unit's power.
[Diagram: Control panel with MIN/MAX adjustment, automatic mode indicator, and multilingual text for settings.]
The unit features automatic flushing based on sensor detection.
Technical Specifications
Pressure Range: 0.1 - 0.8 MPa
Power Supply: 24V DC
Dimensions (approximate):
- Height: 150 mm
- Width: 170 mm
- Depth: 80 mm
[Diagram: SANELA SLP 02K/02KZ unit showing G 3/4" water inlet, 0.1-0.8 MPa pressure gauge, 24V DC power input, and dimensions (150mm H x 170mm W x 80mm D). Mounting holes (M4x50) are indicated.]
Service and Maintenance
Regular checks and proper cleaning are recommended to ensure optimal performance and longevity.
- Frequency: It is recommended to check the electromagnetic valve's sifter and tighten screw connections and connector contact surfaces once a year.
- Cleaning: All stainless steel and chrome components should be cleaned using only water, soap, and a soft rag. Aggressive and abrasive cleansers are strictly forbidden. For stainless steel, SUMA INOX solution is recommended.
- Packaging: Dispose of product packaging according to local regulations.
- Compliance: This product has a declaration of conformity in accordance with regulations 73/023/EEC and 89/336/EEC.
Recommended Accessories
Accessory Code | Description |
---|---|
SLZ 01Y | External power supply 230/24V DC, for connection of max. 5 flushing units |
SLZ 01Z | External power supply 230/24V DC, for connection of max. 9 flushing units |
SLD 03 | Universal remote control for parameters adjustment |
SLA 02 | Inlet fitting for urinals with the back inlet |