Nice DOMI Series Transmitters
This document provides instructions and warnings for the installation and use of Nice DOMI series transmitters, including DOMIW, DOMIP, and MINIDOMI models.
Product Description and Application
The DOMI series transmitters are designed for controlling outdoor automation systems such as shutters, blinds, rolling shutters, or mixed Nice automation systems (scenarios). Any use other than that specified or in different ambient conditions is considered improper and strictly forbidden.
Components of the Transmitters
The DOMI range includes three families: DOMI W (wall-mounted), DOMI P (portable), and MINIDOMI. Each family has various models with different numbers of keys and features like a 'cursor' surface or a display.
Key components include:
- A - Status indicator LED: Signals the automation status.
- B - Command keys: Used for sending commands like open/close and stop.
- C - Automation status request key: Retrieves the current status of the automation.
- D - Group selection keys: Used on multi-key models to select the automation group.
- E - 'Cursor' surface: Allows for simplified command sending on specific models.
- F - Display: Shows the active group on the DOMIP18V model.
- G - Partial position key: Used on the DOMIP18V for partial position commands.
- H - Group selector: Allows group selection on the DOMIP18V.
- P-S - Programming keys: Located on the back for programming procedures.
- L-O - Climatic sensor activation/deactivation keys: Available on DOMIP1SV and DOMIP6SV models.
Using the Keys
- Command Keys (B): Send open/close and stop commands. For multi-key models, select a group first.
- Status Request Key (C): Press to view the automation's current state (open/closed).
- Group Selection Keys (D): Select the automation(s) to control. At least one group must be programmed.
- 'Cursor' Surface (E): Touch or slide for simplified commands. A prolonged press puts the transmitter in standby.
- Display (F): Shows the selected group on the DOMIP18V.
- Partial Position Key (G): Sends partial position commands on the DOMIP18V.
- Group Selector (H): Selects the group on the DOMIP18V.
- Programming Keys (P-S): Accessed from the back for programming. PRG speeds up access, ESC speeds up exit.
- Climatic Sensor Keys (L-O): Activate/deactivate climatic sensors on specific models.
Transmitter Functions
DOMI transmitters are compatible with 'O-Code' (unidirectional) and 'BD' (bidirectional) radio codifications. The 'BD' system offers advanced features like command reception confirmation (LED indicator) and automation status feedback.
Transmitters are factory-configured in bidirectional mode. For coding changes, refer to the relevant section.
Memorization of the Transmitter
Transmitters can be memorized into the receiver using two methods:
- Mode 1 Memorization: Memorizes all transmitter commands at once with factory settings. For multi-key models, select a group first.
- Memorization via an already memorized transmitter: Allows memorizing new transmitters using one that is already programmed within a 20-meter range. For multi-key models, select a group first.
Refer to the receiver's instruction manual for detailed procedures.
Status Request Procedure
Press the 'i' key to request the automation's status. The LED (A) or group key (B) will indicate the status:
- Green: Automation in upper limit position (shutter/blind) or open (gate).
- Red: Automation in lower limit position (shutter/blind) or closed (gate).
- Orange: Partial position.
Coding Change Procedure
This procedure allows changing between 'O-Code' and 'BD' codification. It resets the transmitter to factory settings. Follow the on-screen prompts by pressing PRG, ESC, and the up/down keys simultaneously.
Group Selection Procedure
For DOMIW6, DOMIP6, DOMIP6SV, MINIDOMI6, and DOMIP18V models, select a group before sending commands.
- DOMIW6, DOMIP6, DOMIP6SV, MINIDOMI6: Press a group selection key (A). The corresponding LED stays orange. Multiple groups can be selected.
- DOMIP18V: Use the selector (A) to choose the group (indicated on display B). Then send the command.
After sending a command, the group LED will flash orange and then indicate the result (green for success, red for failure).
Cancellation Procedures
These procedures apply to transmitters configured in bidirectional mode.
- Total Erasure: Resets the transmitter to factory settings, erasing all memorized configurations.
- Group Erasure: Erases automations associated with a specific group for models DOMIW6, DOMIP6, DOMIP6SV, DOMIP18V, and MINIDOMI6.
Follow the specific steps involving the PRG and ESC keys, and the group selection keys.
'Cursor' Surface
The 'cursor' surface on DOMIP1SV, DOMIP6SV, and DOMIP18V models allows simplified command sending. A brief touch or a slide sends commands. A prolonged press activates standby mode.
Climatic Sensor Activation/Deactivation
DOMIP1SV and DOMIP6SV models allow enabling or disabling climatic sensors. Use the '*' key for this function.
Sound Signal Activation/Deactivation
The sound signal (beep) can be activated or deactivated by pressing ESC and the down arrow key (for deactivation) or up arrow key (for activation) simultaneously.
Signals
- On Power-Up: The LED or group keys indicate the transmitter's configuration (green for bidirectional, red for unidirectional).
- Anomalies: The LED or group keys flash red, indicating issues like attempting to transmit without selecting a group or pressing PROG/ESC with multiple groups selected.
- Battery Status: The LED or group keys flash orange slowly when the battery is low.
Battery Replacement
Replace the battery when it is low or depleted. Follow the specific instructions for each model (DOMIW1, DOMIW1, MINIDOMI1, MINIDOMI6, DOMIP1, DOMIP1SV, DOMIP6, DOMIP6SV, DOMIP18V) using the correct battery type (e.g., CR2450, AAA) and observing polarity.
Product Disposal
Dispose of the product and its batteries according to local regulations. Do not discard with household waste due to potential pollutant content. Contact local authorities for proper recycling or disposal methods.
Technical Characteristics
Description | DOMI P | DOMI W | MINIDOMI |
---|---|---|---|
Typology | Bidirectional transmitter | Bidirectional transmitter | Bidirectional transmitter |
Power Supply | 2 x 1.5Vdc AAA type batteries | 3 Vdc CR2450 lithium battery | 2 x 1.5Vdc AAA type batteries |
Battery Life | Estimated 3 years, with 10 transmissions per day | - | - |
Frequency | 433.92 MHz | 433.92 MHz | 433.92 MHz |
Radiated Power (ERP) | < 10 mW | < 10 mW | < 10 mW |
Radio Codification | BD - O-Code | BD - O-Code | BD - O-Code |
Operating Temperature | -5°C ... +55 °C | -5°C ... +55 °C | -5°C ... +55 °C |
Degree of Protection | IP 40 (indoor/protected environment use) | IP 40 (indoor/protected environment use) | IP 40 (indoor/protected environment use) |
Dimensions | 155x43x23 mm | 50x50x13 mm | 71x41x12 mm |
Weight | 75 g | 24 g | 27 g |
Technical characteristics are referenced at an ambient temperature of 20°C (+/- 5°C). Nice S.p.A. reserves the right to modify products without prior notice, ensuring the same functions and intended use.
The range of transmitters and receiver sensitivity can be influenced by other devices operating on the same frequency.
Conformity
EU Declaration of Conformity Simplified
Nice S.p.A. declares that the DOMIW1, DOMIW6, DOMIP1, DOMIP1SV, DOMIP6, DOMIP6SV, DOMIP18V, MINIDOMI1, and MINIDOMI6 products comply with Directive 2014/53/UE. The full text of the EU declaration of conformity is available at: https://www.niceforyou.com/fr/support.
Accessories
DOMI transmitters can be equipped with wall-mounting plates. These are included for DOMIP1, DOMIP1SV, DOMIP6, DOMIP6SV, and DOMIP18V models. For other models, they can be ordered separately. Follow the instructions for fixing the plates and positioning the transmitter.
Models DOMIW1 and DOMIW1: Plates to be ordered separately (Figure 17).
Models MINIDOMI1 and MINIDOMI6: Plates to be ordered separately (Figure 18).
Models DOMIP1, DOMIP1SV, DOMIP6, DOMIP6SV, and DOMIP18V: Plates included in the packaging (Figure 19).