Hunter Xidane 4-Light Vanity Installation Guide

For Models: 19765, 19766

Preparing for Installation

Carefully remove all contents from the carton. Shut off the power at the circuit breaker and completely remove the old fixture from the wall, including the old mounting bracket. Remove the new mounting bracket assembly from the bag. Then remove cap nuts (D) from mounting screws (C). Place the mounting plate (A) over the junction box so that mounting screws (C) and nuts (J) extend out away from the wall. Depending on the placement of your junction box, the position of mounting screws (C) may need to be adjusted to allow the backplate to be flush with the wall. Adjust the position of mounting screws (C) so that mounting screws (C) can be exposed 5-6 mm after passing through the backplate (K) to properly fit the cap nuts. Mounting screws (C) can be adjusted by loosening nuts (J) and loosening or tightening mounting screws (C). Once the ideal position of mounting screws (C) has been confirmed, tighten nuts (J) on mounting screws (C) on the front of the mounting plate to ensure that mounting screws (C) are secure. Pull the house wires through the center of mounting plate (A). Secure mounting plate (A) to the junction box by tightening the screws (B).

Connecting the Wires

Have a helper support the fixture's weight while completing the wiring. Attach the fixture's wires to the power supply wires from the junction box. Connect black to black (Live); white to white (grounded); grounding to grounding (green or copper). Twist the ends of the wire pairs together. Then, twist on a wire connector. Make sure all twists are in the same direction. Loop fixture's ground wire around grounding screw (E) and tighten. If there is no ground wire (green or copper) from the junction box, contact a qualified electrician.

Diagram Description: Fixture wires (Black, White, Bare Copper/Green) connect to House wires (Black, White, Green/Copper) using wire connectors. The fixture's ground wire loops around the grounding screw (E) and is tightened.

Finishing the Installation

Place the fixture's backplate (K) over the mounting screws (C) so the threads protrude through the holes on the front of the backplate. Tightly screw the cap nuts (D) onto the mounting screws (C) until the backplate (K) of the fixture is snugly against the wall. Screw the finial (G) on the fixture (F) beneath each socket and use the socket ring (I) to secure the glass shade (H) to each socket. Install light bulb (not included) in accordance with the fixture's specifications. Do not exceed the recommended wattage. Your installation is now completed. Turn on the power and test the fixture.

Cleaning Tips

Treat the fixture gently! Regular cleaning will reduce the need for deep cleaning. For regular cleaning, turn off the light and wipe down the fixture with a clean lint-free cotton or microfiber cloth. Never spray cleaner directly onto the fixture.

Tools and Parts

Required Tools:

  • Ladder
  • Screwdriver
  • Pliers
  • Wire Strippers

Parts Information:

  • 4 Light Vanity (4.8 lbs / 2.2 kg)
  • Hardware Service Kit: Part # KE19301L24 (Model 19765, Finish: Palm Gold/Dorado Palma/Palmier Doré), Part # KE19301214 (Model 19766, Finish: Brushed Nickel/Níquel Pulido/Nickel Brossé)
  • Glass Shade: Part # KE28301147 (Type: Clear Glass/Vidrio Transparente/Verre Transparent for Models 19765, 19766)

Diagram Description: The document displays an exploded view diagram showing the assembly of the fixture, including the mounting plate (A), mounting screws (C), nuts (J), backplate (K), fixture body (F), finials (G), socket rings (I), and glass shades (H). It also illustrates the required tools: Ladder, Screwdriver, Pliers, and Wire Strippers.

Important Safety Information

WARNING:

  • To avoid possible electrical shock, disconnect power at the circuit breaker before installing.
  • The lighting fixture must be grounded. If a ground wire is not present, stop installation and consult a qualified electrician.
  • All wiring must comply with national and local electrical codes (ANSI/NFPA 70). Consult an electrician if unfamiliar with wiring.
Models: 19766, Xidane 4 Light Vanity, 19766 Xidane 4 Light Vanity, 4 Light Vanity, Light Vanity, Vanity

File Info : application/pdf, 2 Pages, 632.34KB

PDF preview unavailable. Download the PDF instead.

xgse5n4oosqsjez6trym Adobe PDF Library 16.0.3 Adobe InDesign 17.0 (Macintosh)

Related Documents

Preview Hunter Xidane 5-Light Chandelier Installation Guide
Comprehensive installation instructions for the Hunter Xidane 5-Light Chandelier (models 19747, 19748). This guide covers preparation, fixture assembly, wiring connections, final installation steps, and cleaning tips, ensuring a safe and correct setup.
Preview Hunter Redding 48239 Flush Mount Light Fixture Installation Guide
Step-by-step installation instructions for the Hunter Redding 48239 flush mount light fixture, including wiring, mounting, and cleaning tips. Safety warnings and required tools are also provided.
Preview Hunter Kerrison Pendant Light Installation Guide (Models 19538, 19539)
Step-by-step installation instructions for the Hunter Kerrison pendant light, including preparation, assembly, wiring, and finishing. Covers models 19538 and 19539 with detailed guidance.
Preview Hunter Valdaz 48258 3-Light Flush Mount Installation Instructions
Comprehensive installation guide for the Hunter Valdaz 48258 ceiling light fixture, including preparation, wiring, mounting, and cleaning tips.
Preview Hunter Canoga 46062 LED Outdoor Wall Light Installation Guide
Comprehensive installation instructions for the Hunter Canoga 46062 LED outdoor wall light. Covers preparation, wiring, finishing, cleaning, safety, and required tools.
Preview Hunter Rafner 19451 Pendant Light Installation Guide and Manual
Step-by-step installation instructions for the Hunter Rafner 19451 pendant light. This guide covers preparation, assembly, wiring, finishing, and cleaning for models 19449, 19451, 19453, and 19455.
Preview Hunter Xidane 1-Light Pendant Installation Guide
Comprehensive installation instructions for the Hunter Xidane 1-Light Pendant fixture (Models 19504, 19505), covering preparation, assembly, wiring, finishing, cleaning, and safety information.
Preview Hunter Woodburn 2-Light Wall Sconce Installation Guide (Models 19815, 19816)
Step-by-step installation instructions for the Hunter Woodburn 2-Light Wall Sconce (Models 19815, 19816). Includes preparation, wiring, finishing, and cleaning tips.