MEAN WELL APV-12 Series 12W Single Output Switching Power Supply
Features
- Constant voltage design
- Universal AC input / Full range
- Protections: Short circuit / Over load / Over voltage
- Fully isolated plastic case
- Cooling by free air convection
- Small and compact size
- Class II power unit, no FG
- Class 2 power unit
- Pass LPS
- IP42 design
- Suitable for LED related fixture or appliance (such as LED Decoration or Advertisement devices) (Note.7)
- 100% full load burn-in test
- Low cost, high reliability
- 2 years warranty
Specification
GTIN CODE | MW Search: https://www.meanwell.com/serviceGTIN.aspx | ||||
MODEL | APV-12-5 | APV-12-12 | APV-12-15 | APV-12-24 | |
DC VOLTAGE | 5V | 12V | 15V | 24V | |
RATED CURRENT | 2A | 1A | 0.8A | 0.5A | |
CURRENT RANGE | 0~2A | 0~1A | 0~0.8A | 0~0.5A | |
RATED POWER | 10W | 12W | 12W | 12W | |
RIPPLE & NOISE (max.) Note.2 | 100mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | |
VOLTAGE TOLERANCE Note.3 | ±5.0% | ||||
LINE REGULATION | ±1.0% | ||||
LOAD REGULATION | ±2.0% | ||||
SETUP, RISE TIME | 20ms/230VAC | 1500ms, 30ms / 230VAC | |||
HOLD UP TIME (Тур.) Note.6 | 15ms/115VAC at full load | 1500ms, 30ms / 115VAC at full load | |||
VOLTAGE RANGE Note.4 | 90~264VAC / 127~370VDC | ||||
FREQUENCY RANGE | 47~63Hz | ||||
EFFICIENCY (Typ.) | 76% | 82% | 82% | 84% | |
AC CURRENT | 0.2A/230VAC | 0.35A/115VAC | |||
INRUSH CURRENT(Typ.) | COLD START 70A(twidth=185µs measured at 50% Ipeak) at 230VAC | ||||
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 17 units (circuit breaker of type B) / 29 units (circuit breaker of type C) at 230VAC | ||||
LEAKAGE CURRENT | 0.25mA/240VAC | ||||
OVER LOAD PROTECTION | Above 105% rated output power. Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||||
OVER VOLTAGE PROTECTION | 5.75~6.75V | 13.8~16V | 17.5~21V | 27.6~32.4V | |
WORKING TEMP. | -30~+70°C (Refer to "Derating Curve") | ||||
WORKING HUMIDITY | 20~90% RH non-condensing | ||||
STORAGE TEMP., HUMIDITY | -40~+80℃, 10~95% RH | ||||
TEMP. COEFFICIENT | ±0.03%/℃ (0~50℃) | ||||
VIBRATION | 10~500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | ||||
SAFETY STANDARDS Note.8 | UL8750, CSA C22.2 No.250.0-08, BIS IS15885 (except for 15V), EAC TP TC 004, IP42, BS EN/EN 62368-1 approved | ||||
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC | ||||
SAFETY & EMC | ISOLATION RESISTANCE | I/P-O/P:>100M Ohms / 500VDC/25°C/70% RH | |||
EMC EMISSION | Compliance to BS EN/EN55032, BS EN/EN61000-3-2, BS EN/EN61000-3-3, EAC TP TC 020 | ||||
EMC IMMUNITY | Compliance to BS EN/EN55035, BS EN/EN61000-4-2,3,4,5,6,8,11; light industry level (surge 2KV), EAC TP TC 020 | ||||
MTBF | 7488.9K hrs min. Telcordia SR-332 (Bellcore); | 1132.5K hrs min. MIL-HDBK-217F (25°C) | |||
OTHERS | DIMENSION | 77*40*29(L*W*H) | |||
PACKING | 0.08Kg; 120pcs/11.8Kg/1.06CUFT |
Notes
- All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
- Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- Tolerance: includes set up tolerance, line regulation and load regulation.
- Derating may be needed under low input voltage. Please check the static characteristics for more details. Please connect L line to the positive pole and N line to the negative pole under DC input.
- The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
- Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
- This product is not intended for LED lighting luminaire applications in the EU. (In the EU the LPF/NPF/XLG series are recommended.)
- The model certified for CCC(GB19510.14, GB19510.1, GB17743 and GB17625.1) is an optional model. Please contact MEAN WELL for details.
- The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft).
- Products sourced from the Americas regions may not have the ENEC/BIS/CCC logo. Please contact your MEAN WELL sales for more information.
- For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf
Mechanical Specification
The power supply has a compact plastic case with dimensions of 77*40*29mm (L*W*H). It features AC input terminals (L and N) and DC output terminals (+V and -V). The case temperature should not exceed the specified limit (T case).
Refer to the diagram for detailed dimensions and terminal connections.
Block Diagram
The block diagram illustrates the internal components and signal flow of the power supply. It includes an EMI filter, rectifiers, a power switching section with PWM control, and output rectifiers and filters. A detection circuit is also present.
Derating Curve
The derating curve shows the relationship between ambient temperature and load percentage. For the 5V model, the derating starts at approximately 45°C. For other models, derating begins at a higher temperature, around 50°C.
Static Characteristics
The static characteristics graph displays the load percentage versus input voltage. The power supply operates efficiently across a wide input voltage range, typically from 100VAC to 240VAC, maintaining a high load percentage.
For detailed information, please refer to https://www.meanwell.com/service Disclaimer.aspx