Nov 29, 2022 — SAFETY WARNING. Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, ...
File Info : application/pdf, 2 Pages, 976.96KB
DocumentDocumentInstallation Instructions Low Static Drive Kit FoundationTM Packaged Rooftop Units 15 to 25 Tons Model Number: BAYLSDR300* BAYLSDR302* Used With: E/GCC180-300A3,4,W EAC180-270AD SAFETY WARNING Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. December 2022 ACC-SVN169F-EN ©2022 4 2. Compare the order number on the shipping label with the accessory identification information on the ordering and shipping documents to verify that the correct accessory has been received. Parts List Table 1. Qty 1 1 1 1 1 Parts list Description Fan sheave for G/ECC180A3,4,W Motor sheave and Fan sheave for G/ECC210-240A3,4,W Motor sheave for GCC300A3,4,W Belt Accessory label Figure 1. Indoor motor assembly Bolt used for belt adjustment 1 Warnings, Cautions, and Notices Read this manual thoroughly before operating or servicing this unit. Safety advisories appear throughout this manual as required. Your personal safety and the proper operation of this machine depend upon the strict observance of these precautions. The three types of advisories are defined as follows: WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION NOTICE Indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury. It could also be used to alert against unsafe practices. Indicates a situation that could result in equipment or property-damage only accidents. Important Environmental Concerns Scientific research has shown that certain man-made chemicals can affect the earth's naturally occurring stratospheric ozone layer when released to the atmosphere. In particular, several of the identified chemicals that may affect the ozone layer are refrigerants that contain Chlorine, Fluorine and Carbon (CFCs) and those containing Hydrogen, Chlorine, Fluorine and Carbon (HCFCs). Not all refrigerants containing these compounds have the same potential impact to the environment. Trane advocates the responsible handling of all refrigerantsincluding industry replacements for CFCs such as HCFCs and HFCs. Important Responsible Refrigerant Practices Trane believes that responsible refrigerant practices are important to the environment, our customers, and the air conditioning industry. All technicians who handle refrigerants must be certified according to local rules. For the USA, the Federal Clean Air Act (Section 608) sets forth the requirements for handling, reclaiming, recovering and recycling of certain refrigerants and the equipment that is used in these service procedures. In addition, some states or municipalities may have additional requirements that must also be adhered to for responsible management of refrigerants. Know the applicable laws and follow them. 2 WARNING Proper Field Wiring and Grounding Required! Failure to follow code could result in death or serious injury. All field wiring MUST be performed by qualified personnel. Improperly installed and grounded field wiring poses FIRE and ELECTROCUTION hazards. To avoid these hazards, you MUST follow requirements for field wiring installation and grounding as described in NEC and your local/state/national electrical codes. WARNING Personal Protective Equipment Required! Failure to wear proper PPE for the job being undertaken could result in death or serious injury. Technicians, in order to protect themselves from potential electrical, mechanical, and chemical hazards, MUST follow precautions in this manual and on the tags, stickers, and labels, as well as the instructions below: · Before installing/servicing this unit, technicians MUST put on all PPE required for the work being undertaken (Examples; cut resistant gloves/sleeves, butyl gloves, safety glasses, hard hat/bump cap, fall protection, electrical PPE and arc flash clothing). ALWAYS refer to appropriate Safety Data Sheets (SDS) and OSHA guidelines for proper PPE. · When working with or around hazardous chemicals, ALWAYS refer to the appropriate SDS and OSHA/GHS (Global Harmonized System of Classification and Labelling of Chemicals) guidelines for information on allowable personal exposure levels, proper respiratory protection and handling instructions. · If there is a risk of energized electrical contact, arc, or flash, technicians MUST put on all PPE in accordance with OSHA, NFPA 70E, or other country-specific requirements for arc flash protection, PRIOR to servicing the unit. NEVER PERFORM ANY SWITCHING, DISCONNECTING, OR VOLTAGE TESTING WITHOUT PROPER ELECTRICAL PPE AND ARC FLASH CLOTHING. ENSURE ELECTRICAL METERS AND EQUIPMENT ARE PROPERLY RATED FOR INTENDED VOLTAGE. 3 WARNING Follow EHS Policies! Failure to follow instructions below could result in death or serious injury. · All Trane personnel must follow the company's Environmental, Health and Safety (EHS) policies when performing work such as hot work, electrical, fall protection, lockout/tagout, refrigerant handling, etc. Where local regulations are more stringent than these policies, those regulations supersede these policies. · Non-Trane personnel should always follow local regulations. Copyright This document and the information in it are the property of Trane, and may not be used or reproduced in whole or in part without written permission. Trane reserves the right to revise this publication at any time, and to make changes to its content without obligation to notify any person of such revision or change. Trademarks All trademarks referenced in this document are the trademarks of their respective owners. Revision History · Model number updates in Used With information. · Updated Table 1 and Table 2 data in Installation section. General Information The low static kit may be used when the required CFM can not be delivered with the standard motor and sheaves. Refer to Table 3 for proper selection of sheave and belt based on desired fan speed (RPM). Inspection 1. Inspect the shipping carton and its contents. Check for concealed damage before it is stored or used. If any damage is found, report it immediately, and file a claim against the transportation company. Replace damaged parts with authorized parts only. 5 Installation Refer to Figure 1 when reading these instructions. WARNING Hazardous Voltage w/Capacitors! Failure to disconnect power and discharge capacitors before servicing could result in death or serious injury. Disconnect all electric power, including remote disconnects and discharge all motor start/run capacitors before servicing. Follow proper lockout/ tagout procedures to ensure the power cannot be inadvertently energized. Verify with a CAT III or IV voltmeter rated per NFPA 70E that all capacitors have discharged. 1. Ensure that all power to the unit has been disconnected and locked off. 2. Remove the evaporator fan access panel. 3. Loosen the locknut and tension adjustment bolt on the motor plate assembly and remove the belt. See Figure 1. A belt tightening instruction label is glued to the motor mounting plate. 4. Remove the existing: · Fan sheave for G/ECC180A3,4,W · Motor and fan sheave for G/ECC210-240A3,4,W · Motor sheave for GCC300A3,4,W 5. Install: · The replacement fan sheave for G/ECC180A3,4,W · The motor and fan sheaves for G/ECC210-240A3,4,W · The motor sheave for G/ECC300A3,4,W NOTICE Equipment Damage! Proper adjustment of the fan belt is important to ensure optimal unit operation. Over tightening or under tightening the fan belt can result in belt slippage and excessive wear, bearing damage, sheave misalignment, and possible failure of fan motor mounts. 6. Adjust the motor sheave to the proper turns open for the required RPM to produce the desired airflow. Refer to Table 2 and Table 3 for the sheave data. 6 7. Check the alignment between the fan and motor sheaves using a straight edge. Adjust as necessary. Torque the fan and motor sheave set screws to 126 to 165 inch pounds (14.2 to 18.6 N-m). 8. Torque the motor securing bolts to 144 to 151 inch pounds (16.3 to 17.1 N-m). NOTICE Equipment Damage! Proper adjustment of the fan belt is important to ensure optimal unit operation. Over tightening or under tightening the fan belt can result in belt slippage and excessive wear, bearing damage, sheave misalignment, and possible failure of fan motor mounts. 9. Adjust the tension of the fan belt. The correct operating tension for a V-belt fan drive is the lowest tension at which the belt will not slip under peak load conditions. The locknut should be tightened sufficiently to ensure that the motor plate assembly maintains the desired belt tension. Note: The new V-belts tend to stretch after having been placed in operation. Periodically check the tension of the belt. WARNING Live Electrical Components! Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. When it is necessary to work with live electrical components, have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. 10.Being careful not to touch any electrical or moving parts, close the unit disconnect switch, and check the unit supply fan for minimum vibration. WARNING Hazardous Voltage w/Capacitors! Failure to disconnect power and discharge capacitors before servicing could result in death or serious injury. Disconnect all electric power, including remote disconnects and discharge all motor start/run capacitors before servicing. Follow proper lockout/ tagout procedures to ensure the power cannot be inadvertently energized. Verify with a CAT III or IV voltmeter rated per NFPA 70E that all capacitors have discharged. 7 11.Open and lock the disconnect switch in the off position. 12.Replace all panels. 13.Close the unit disconnect switch. Table 2. Standard motor and low static drive accessory sheave / fan speed (rpm) Tons Unit Model Number 6 5 4 3 2 1 Turns Turns Turns Turns Turns Turn Open Open Open Open Open Open Closed 15 E/G*C180A3,4,W 488 523 558 592 627 662 N/A 17.5 E/G*C210A3,4,W 560 596 632 668 703 739 N/A G*C240A3,4,W 627 672 717 762 806 851 N/A 20 E*C240A3,4,W 538 574 609 645 681 717 N/A G*C300A3,4,W 838 891 943 995 1048 1100 N/A 25 E*C300A3,4,W 729 775 821 866 912 957 N/A Note: Factory set at 3 turn open. 8 Table 3. Tons 15 17.5 20 22 25 Low static drive kit components Unit Model Number G/ECC180A3,4,W EAC180AD GCC210A3,4,W ECC210A3,4,W EAC210AD GCC240A3,4,W ECC240A3,4,W EAC240AD EAC270AD GCC300A3,4,W ECC300A3,4,W Fan Sheave BK105 BK160 BK160 BK160 BK130 BK160 BK160 BK130 BK130 BK160 Motor Sheave 1VP34 1VP34 1VP34 1VL40 1VL34 1VP44 1VP44 Belt BX48 BX58 BX58 BX58 BX52 BX58 BX58 BX54 BX54 BX56 BX60 Trane and American Standard create comfortable, energy efficient indoor environments for commercial and residential applications. For more information, please visit trane.com or americanstandardair.com. Trane and American Standard have a policy of continuous product and product data improvement and reserve the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. ACC-SVN169F-EN 03 Dec 2022 Supersedes ACC-SVN169E-EN (Apr 2020) ©2022