How to operate the OC-S10:

The OC-S10 requires phantom power, so please make sure that you are supplying it according to the IEC 61938 technical standard P48 (48V +/- 4V). The idle current consumption is below 3 mA. Almost all state-of-the-art professional mixing consoles, preamps and audio interfaces provide enough power, however some battery driven or older devices may fail to provide adequate power!

Setting up the OC-S10:

For optimum performance, do not cover the grille of the OC-S10, and always ensure a secure fit within the OCSM10 shock mount. Hold the microphone tightly in one hand and turn the shock mount thread with the other hand. If needed, use the frameless OCPF10 metal mesh pop filter with magnetic mounts. The frameless design eliminates plosive sounds without any physical obstruction.

Plug in XLR cable(s):

For normal operation you only need to connect an XLR cable to the main (front) output. The second XLR output can be used to record the rear capsule signal separately.

Note: An XLR cable must be physically connected to the main XLR output before plugging in a cable to the rear output. If no cable is plugged into the main output, the Sequential Lockout will block the rear output.

To quickly find the main output on the bottom side by feel there is an orientation protrusion close to the main socket.

Polar Pattern Selection:

The OC-S10 is a multi-pattern microphone, providing 5 different directional characteristics: omnidirectional, wide cardioid, cardioid, hypercardioid and figure of 8. Please select your desired polar pattern by adjusting the pattern ring.

Our logo marks the front side of the microphone. Please arrange the microphone so that your sound source faces the logo.

The directional characteristics are: Omnidirectional, Wide Cardioid, Cardioid, Hypercardioid, and Figure of 8.

Dual Mode:

The second output on the bottom side of the microphone delivers the signal of the rear membrane, while the front capsule signal is delivered on the main XLR connector. Plug in a second 3pin XLR cable and set the polar pattern switch to the position showing the 2 cardioids.

The OC-S10 will now work in dual mode, with the signal from both of the capsule membranes being transmitted independently. In dual mode, you may record the two signals to two tracks and use our PolarDesigner (or StereoCreator) plugins to modify the polar pattern in post-production.

Low Cut Filter:

The low-cut filter is a powerful tool to reduce unwanted low frequency material, such as stage and handling noise.

Switchable Pad:

The Pad reduces the sensitivity of the microphone and prevents overloading the signal in loud environments.

How to replace the suspension pads on your OCSM10 shock mount:

  1. Start by removing the top suspension on one side of the shock mount. Remove it from the two outer, smaller mount points first, from the larger mount point last.
  2. Remove the bottom suspension on the same side. Start at the larger mount point and slip the suspension pad over the rod and larger top mount point. Remove completely via the two outer, smaller mount points.
  3. Repeat steps 1-2 on the other side.
  4. To install the replacement suspension pads, start on one side. First place the new pad's larger hole over the larger top mount point and slip it onto the rod to properly position it at the bottom. Then slip it over the two smaller, outer mount points. Please note the direction of the pads. The flat side of the bottom pads needs to face downwards!
  5. Press the top pad over the bigger top mount point first, then slip it over the two smaller, outer mount points. Please note the direction of the pads. The flat side of the top pads needs to face upwards.
  6. Repeat steps 4-5 on the other side.

Product Specifications

Directional characteristics Omnidirectional, Wide cardioid, Cardioid, Hypercardioid, Figure-of-Eight, Individual (with Dual Output)
Frequency range 20 Hz – 22 kHz
Sensitivity 14 mV/Pa
Equivalent noise level 8 dB SPL (A)
Max. SPL 147 (157) dB SPL
Low Cut filter 40 Hz (2nd order), 80 Hz (2nd order), 160 Hz (1st order down to 80 Hz, 2nd order below)
Switchable pad -10 dB, -20 dB
Impedance 108 Ω (symmetrical)
Load impedance > 1 ΚΩ
Supply voltage 48 V (< 3 mA)
Connectors 2x XLR 3pin
Dimensions 205 x 63 x 63 mm
Weight 710 g

Frequency Response and Polar Patterns

The document includes detailed frequency response graphs and polar pattern diagrams for the OC-S10 microphone across its various directional characteristics: Omnidirectional, Wide Cardioid, Cardioid, Hypercardioid, and Figure Eight.

Made in Austria

This product conforms to the standards listed in the Declaration of Conformity and can be found at https://austrian.audio/OC-S10

Copyright Austrian Audio 2025.

All rights reserved by Austrian Audio GmbH, Eitnergasse 15, 1230 Vienna. support@austrianaudio.com

Models: OC-S10 Reference Recording Microphone, OC-S10, Reference Recording Microphone, Recording Microphone, Microphone

File Info : application/pdf, 6 Pages, 684.98KB

PDF preview unavailable. Download the PDF instead.

OC-S10 Manual v1 EN

References

Adobe PDF Library 25.1.51

Related Documents

Preview OC-S10 Referenz Studio Mikrofon Bedienungsanleitung
Umfassende Bedienungsanleitung für das Austrian Audio OC-S10 Referenz Studio Mikrofon, einschließlich Einrichtung, Bedienung, Sicherheitshinweisen und technischen Spezifikationen.
Preview Austrian Audio OC-S10 EU Declaration of Conformity
EU Declaration of Conformity for the Austrian Audio OC-S10 microphone, confirming compliance with RoHS and EMC directives.
Preview Austrian Audio OC707 Quick Start Guide: Professional Microphone Setup
Get started quickly with your Austrian Audio OC707 microphone. This guide covers essential setup, connection details, safety information, and key features like its cardioid polar pattern and 120 Hz high-pass filter.
Preview Austrian Audio OC-S10 Declaration of Conformity
Official EU Declaration of Conformity for the Austrian Audio OC-S10 microphone, confirming compliance with RoHS and EMC directives.
Preview Austrian Audio OD505 Active Dynamic Vocal Microphone Owner's Manual
Comprehensive owner's manual for the Austrian Audio OD505 Active Dynamic Vocal Microphone, covering safety instructions, operation, and features. Learn how to use and care for your OD505.
Preview Austrian Audio OD505 Quick Start Guide - Dynamic Supercardioid Microphone
Concise guide to setting up and using the Austrian Audio OD505 dynamic microphone, covering power, connections, polar pattern, and high-pass filter.
Preview Austrian Audio OD505 Microphone Quick Start Guide
Quick start guide for the Austrian Audio OD505 microphone, covering setup, features, safety information, and disposal instructions. Includes details on phantom power, OCH1 holder, polar pattern, and high-pass filter.
Preview Austrian Audio OD303 Quick Start Guide: Features, Safety, and Usage
Concise guide for the Austrian Audio OD303 microphone, covering safety precautions, product features, connectivity, polar pattern, and included accessories. Includes compliance information and contact details.