MEAN WELL LRS-450 Series 450W Single Output Switching Power Supply
Key Features
- MEAN WELL patent pending (Application number CN202220241473.0, CN202230060511.8)
- AC input range selectable by switch
- Withstands 300VAC surge input for 5 seconds
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Forced air cooling with built-in fan ON-OFF control
- 1U low profile design
- Withstands 5G vibration test
- High operating temperature up to 70°C
- Operating altitude up to 5000 meters (Note.10)
- 3 years warranty
- MTBF > 1KK hrs
Description
The LRS-450 series is a 450W single-output enclosed type power supply featuring a 35mm low profile design. It accepts AC input of 115 VAC or 230 VAC (selectable by switch) and offers output voltages of 5V, 12V, 15V, 24V, 36V, and 48V. With high efficiency up to 92% and a built-in long-life fan, the LRS-450 operates at full load in temperatures ranging from -20°C to +70°C. It includes complete protection functions and 5G anti-vibration capability, complying with international safety regulations. The LRS-450 series provides a high price-to-performance power supply solution for various industrial applications.
Model Encoding
The model number is structured as LRS-450-X, where 'X' denotes the output voltage. For example, LRS-450-5 indicates a 5V output.
Specifications
| MODEL | LRS-450-5 | LRS-450-12 | LRS-450-15 | LRS-450-24 | LRS-450-36 | LRS-450-48 |
|---|---|---|---|---|---|---|
| OUTPUT DC VOLTAGE | 5V | 12V | 15V | 24V | 36V | 48V |
| RATED CURRENT | 75A | 37.5A | 30A | 18.8A | 12.5A | 9.4A |
| CURRENT RANGE | 0 ~ 75A | 0 ~ 37.5A | 0 ~ 30A | 0 ~ 18.8A | 0 ~ 12.5A | 0 ~ 9.4A |
| RATED POWER | 375W | 450W | 450W | 451.2W | 450W | 451.2W |
| RIPPLE & NOISE (max.) Note.2 | 200mVp-p | 200mVp-p | 200mVp-p | 240mVp-p | 360mVp-p | 360mVp-p |
| VOLTAGE ADJ. RANGE Note.3 | 4.75 ~ 5.5V | 11.4 ~ 13.2V | 14.25 ~ 16.5V | 22.8 ~ 26.4V | 34.2 ~ 39.6V | 45.6 ~ 52.8V |
| VOLTAGE TOLERANCE Note.4 | ±2.0% | ±1.5% | ±1.0% | ±1.0% | ±1.0% | ±1.0% |
| LINE REGULATION Note.5 | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
| LOAD REGULATION Note.6 | ±2.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
| SETUP, RISE TIME Note.7 | 1500ms, 50ms/230VAC; 1500ms, 50ms/115VAC at full load | |||||
| HOLD UP TIME (Typ.) | 16ms/230VAC; 12ms/115VAC at full load | |||||
| INPUT VOLTAGE RANGE Note.8 | 90 ~ 132VAC / 180 ~ 264VAC (selectable by switch); 255 ~ 370VDC (switch on 230VAC) | |||||
| FREQUENCY RANGE | 47 ~ 63 Hz | |||||
| EFFICIENCY (Typ.) | 87% | 90% | 90% | 91% | 92% | 92% |
| AC CURRENT (Typ.) | 10A/115VAC; 6A/230VAC | |||||
| INRUSH CURRENT (Typ.) | 35A/115VAC; 60A/230VAC | |||||
| LEAKAGE CURRENT | <2 mA / 240 VAC | |||||
| PROTECTION (Note.9) OVER LOAD | 105 ~ 150% rated output power; Constant current limiting, unit will shutdown after 3 sec. re-power on to recover | |||||
| OVER VOLTAGE | 5.75 ~ 6.75V | 13.8 ~ 16.2V | 18 ~ 21V | 27.6 ~ 32.4V | 41.4 ~ 48.6V | 55.2 ~ 64.8V |
| Protection type | Shut down o/p voltage, re-power on to recover | |||||
| OVER TEMPERATURE | Shut down o/p voltage, re-power on to recover | |||||
| FUNCTION FAN ON/OFF CONTROL (Typ.) | RTH3 ≥ 50°C FAN ON, ≤ 40°C FAN OFF | |||||
| ENVIRONMENT WORKING TEMP. | -20 ~ +70°C (Refer to "Derating Curve") | |||||
| WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||
| STORAGE TEMP, HUMIDITY | -40 ~ +85°C, 10 ~ 95% RH | |||||
| TEMP. COEFFICIENT | ±0.03% / °C (0 ~ 50°C) | |||||
| VIBRATION | 10 ~ 500 Hz, 5G, 10 min./1 cycle, 60 min. each along X, Y, Z axes | |||||
| SAFETY STANDARDS | BS IEC/UL 62368-1, EAC TP TC 004, AS/NZS 62368.1 approved, BIS IS13252(Part1):2010/IEC60950-1:2005 (except for 48V)(pending), BSMI CNS15598-1(pending) | |||||
| WITHSTAND VOLTAGE | I/P-O/P: 3KVAC; I/P-FG: 2KVAC; O/P-FG: 0.5KVAC | |||||
| ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC / 25°C / 70% RH | |||||
| EMC EMISSION | Compliance to EAC TP TC 020, BSMI CNS15936(pending) | |||||
| EMC IMMUNITY | Compliance to EAC TP TC 020 | |||||
| OTHERS MTBF | 1508.9K hrs min. Telcordia SR-332(Bellcore); 252.2K hrs min. MIL-HDBK-217F (25°C) | |||||
| DIMENSION | 225*124*35 mm (L*W*H) | |||||
| PACKING | 0.85 Kg / 15 pcs / 14.11 Kg / 0.85 CUFT | |||||
Notes
- All parameters not specially mentioned are measured at 230VAC input, rated load, and 25°C ambient temperature.
- Ripple & noise are measured at 20 MHz bandwidth using a 12" twisted pair-wire terminated with a 0.1uF & 47uF parallel capacitor.
- Voltage adjustment is only operational within the input range of 100-120VAC or 200-240VAC. Adjusting voltage outside this range may cause abnormal output.
- Tolerance includes set up tolerance, line regulation, and load regulation.
- Line regulation is measured from low line to high line at rated load.
- Load regulation is measured from 0% to 100% rated load.
- Setup time is measured at cold start. Frequent power cycling may increase setup time.
- Derating may be needed under low input voltages. Refer to "Static Characteristics" for details.
- Once protections are triggered, a 3-minute (Typ.) cooldown period is required before restart.
- Ambient temperature derating of 5°C/1000m is needed for operating altitudes above 2000m (6500ft).
- This power supply does not meet the harmonic current requirements outlined by EN61000-3-2. It should not be used under the following conditions: a) end-devices used within the European Union, b) end-devices connected to public mains supply with 220Vac or greater rated nominal voltage, and c) the power supply is installed in end-devices with average or continuous input power greater than 75W, or belongs to a lighting system. Exceptions apply for professional equipment with total rated input power > 1000W and symmetrically controlled heating elements with rated power ≤ 200W.
Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
Block Diagram
The block diagram illustrates the internal components and signal flow of the LRS-450 series power supply, including EMI filter, rectifiers, power switching, PWM control, and output stages with protections.
Derating Curve
The derating curves show the relationship between load percentage and ambient temperature, and load percentage and input voltage (60Hz). These curves indicate the operational limits to ensure reliable performance.
Mechanical Specification
The mechanical specifications provide the physical dimensions of the LRS-450 series power supply, including length, width, height, and mounting hole details. The diagram shows the unit dimensions as 225mm x 124mm x 35mm.
Terminal Pin Assignment:
- Pin 1: AC/L
- Pin 2: AC/N
- Pin 3: FG (Frame Ground)
- Pins 4-6: DC OUTPUT -V
- Pins 7-9: DC OUTPUT +V
Installation Manual
For detailed installation instructions, please refer to the manual available at: http://www.meanwell.com/manual.html