Instruction Manual for BEA models including: IS40, IS40XL, IS40 XL Motion and Presence Sensor, Motion and Presence Sensor, Presence Sensor, Sensor
Constantly be aware of pedestrian/vehicle traffic around the area. ... After unlocking, the red LED flashes and the sensor can be adjusted by remote control. If ...
Products and Accessories Archives | BEA Sensors
File Info : application/pdf, 12 Pages, 4.22MB
DocumentDocumentENGLISH Visit website for available languages of this document. 1 2 3 4 5 1. push buttons 2. LEDs 3. infrared detection (AIR) 4. radar angle 5. radar detection 6. sensor angle indicator 7. bracket 8. cable IS40 / IS40 XL Motion and presense sensor for automatic industrial doors (US version) IS40: for normal to high mounting 8 16 ft IS40 XL: for low mounting 6.5 11.5 ft 6 7 8 75.5695.09 IS40 IS40XL 20230908 Page 1 of 12 TECHNICAL SPECIFICATIONS Supply voltage: 12 24 VAC +10%, 12 24 VDC +10% / -3% Power consumption: < 3.5 W Mains frequency: 50 60 Hz Output: max. contact voltage: max. contact current: max. switching power: Mounting height*: Temperature range: 2 relays (free of potential change-over contact) 42 VAC/VDC 1 A (resistive) 30 W (DC) / 48 VA (AC) IS40: 8 16' IS40 XL: 6.5 11.5' -22 140 °F Humidity: 0 95% non-condensing Degree of protection: IP65 / NEMA4 DImensions: 3.75" (W) × 4" (H) × 5" (D) Materials: ABS and polycarbonate Weight: 14 oz Cable length: 32' Norm conformity: R&TTE 1999/5/EC; EMC 2004/108/EC, R&TTE: 1999/5/EC green red Technology: Transmitter frequency/ wavelength: Output holdtime: Transmitter power density: Detection mode: Detection field: microwave doppler radar 24.150 GHz 0.5 9 s < 5 mW/cm2 motion IS40: 13' × 16.5' IS40 XL: 13' × 6.5' measured at 30º, field size 9, mounting height 16' × 11.5' Min. detection speed: Reaction time: Tilt angle: 2 in/s 100 ms -8 22º (relative to sensor front face) active infrared (AIR) 875 nm 0.5 s < 250 mW/cm2 presence IS40: 10' × 10' IS40 XL: 7.5' × 7.5' zone detected with SPOTFINDER; therefore, slightly larger than the effective detection field 0 in/s to activate detection 250 ms 15 45º Specifications are subject to change without prior notice. All values measured in specific conditions. Page 2 of 12 75.5695.09 IS40 IS40XL 20230908 PRECAUTIONS This device is NOT intended for use as a safety sensor. ! Shut off all power going to header before attempting any wiring procedures. Maintain a clean and safe environment when working in public areas. CAUTION Constantly be aware of pedestrian/vehicle traffic around the area. Always stop pedestrian/vehicle traffic through the doorway when performing tests that may result in unexpected reactions by the door. ESD (electrostatic discharge): Circuit boards are vulnerable to damage by electrostatic discharge. Before handling any board, ensure you dissipate your body's ESD charge. Always check placement of all wiring before powering up to ensure that moving door parts will not catch any wires and cause damage to equipment. Ensure compliance with all applicable safety standards upon completion of installation. DO NOT attempt any internal repair of the components. All repairs and/or component replacements must be performed by BEA, Inc. Unauthorized disassembly or repair: 1. May jeopardize personal safety and may expose one to the risk of electrical shock. 2. May adversely affect the safe and reliable performance of the product resulting in a voided warranty. Only trained and qualified personnel may install and setup the sensor. Only trained and qualified personnel are recommended to install and set up the sensor. Always test the proper operation of the installation before leaving the premises. 75.5695.09 IS40 IS40XL 20230908 The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel. Page 3 of 12 LED INDICATIONS AND SYMBOLS Activation/Pulse detection green LED flashes Value indication for manual setup green Setup red/green Presence detection FACTORY VALUES red LED flashes Parameter indication for manual setup red LED flashes quickly red USEFUL DIMENSIONS Wall mounting Ceiling mounting MOUNTING TIPS Bracket dimensions Do not cover the sensor. Avoid extreme vibrations. Avoid proximity to neon lamps or moving objects. Avoid exposing the sensor to sudden temperature changes. Page 4 of 12 75.5695.09 IS40 IS40XL 20230908 1 MOUNTING 1 2 Remove the bracket from the sensor. Drill 2 holes accordingly. Secure the bracket. Position the sensor on the bracket and tighten the screws. 2 WIRING RED BLACK WHITE GREEN YELLOW WHITE/BLACK GREEN/BLACK YELLOW/BLACK POWER SUPPLY 12 24 VAC/VDC COM NO NC COM NO NC RADAR OUTPUT Motion signal AIR OUTPUT Presence signal 3 SENSOR ANGLE RELAY CONFIGURATION Motion Relay 1 Active 2 Passive 3 Passive 4 Active Presence Relay Passive Active Passive Active 1-4 Description Active Relay Detection NO COM NC No Detection NO COM NC Passive Relay COM NO COM NC NO NC 1 CEILING 2 WALL Adjust the angle of the sensor to position the detection fields. Tighten the screws firmly. 15° 30° 45° RECOMMENDED · The graphics above are not to scale and are for illustration purposes only. These graphics represent approximate detection fields when mounted at 16 feet high. AIR-Infrared field = emitting spots detectable by using the SPOTFINDER. The actual detection field is slightly smaller and is influenced by external factors. · It's important to adjust the sensor angle to position the detection fields correctly for your application. Utilizing a mounting bracket, sensor location, and reveal will dictate the sensor angle for your application. 75.5695.09 IS40 IS40XL 20230908 Page 5 of 12 HOW TO USE THE REMOTE CONTROL After unlocking, the red LED flashes and the sensor can be adjusted by remote control. If the red LED flashes quickly after unlocking, enter an access code from 1 to 4 digits. If you do not know the access code, cut and restore the power supply and within the first minute, you can access the sensor without introducing any access code. ADJUSTING ONE OR MORE PARAMETERS CHECKING A VALUE RESTORING TO FACTORY VALUES x The number of flashes indicates the value of the chosen parameter. SAVING AN ACCESS CODE access code recommended for sensors installed close to each other DELETING AN ACCESS CODE If you do not know the access code, cycle the power and within the first minute, you can access the sensor without entering an access code. Additionally within the first minute, you may delete an unknown access using the remote control (see steps below). DELETING AN UNKNOWN ACCESS CODE Page 6 of 12 75.5695.09 IS40 IS40XL 20230908 4 RADAR FIELD AND AIR PATTERN 1 2 0 9 3 1 6 Turn this screw to adjust the radar Adjust the field size. p. 6 Choose the appropriate p. 6 field angle from -8° to 22°. S = 2, L = 7. detection filter for your application. The total angle is the sum of the sensor angle and the radar field angle. SENSOR ANGLE + RADAR FIELD ANGLE = TOTAL ANGLE All detection field dimensions were measured in optimal conditions with a sensitivity value of 7. f 63036 f 4 8 ft 8 11.5 ft 12 16 ft 16 20 Sensor angle: 30° Radar field angle: -8° Total angle: 22° IS40 f 6 30 3 6 f 4 8 ft 8 12 11.5 ft 16 16 ft 20 Sensor angle: 30° Radar field angle: 0° Total angle: 30 ° f 63036 f 4 8 8 ft 12 16 20 11.5 ft 16 ft Sensor angle: 30° Radar field angle: +11° 11 Total angle: 41° f 63036 f 8 ft 4 10 ft 8 11.5 ft 12 16 20 IS40 XL f 63036 f 8 ft 4 10 ft 8 11.5 ft 12 16 20 f 63036 f 4 8 ft 8 10 ft 11.5 ft 12 16 20 Sensor angle: 30° Radar field angle: -8° Total angle: 22° Sensor angle: 30° Radar field angle: 0° Total angle: 30 ° Sensor angle: 30° Radar field angle: +11° 11 Total angle: 41° 75.5695.09 IS40 IS40XL 20230908 Page 7 of 12 POSSIBLE REMOTE CONTROL SETTINGS (motion sensing) FIELD SIZE (SENSITIVITY) HOLD-OPEN TIME DETECTION MODE XXS XS S > > > > L XL XXL 0.5 s 1 s 2 s 3 s 4 s 5 s 6 s 7 s 8 s 9 s bi uni uni AWAY bi = two-way detection uni = one-way detection towards sensor uni AWAY = one-way detection away from sensor DETECTION FILTER (REJECTION MODE) 1 2 3 4 5 6 Detection of ALL TARGETS (pedestrians, vehicles and parallel traffic are detected) Detection only of VEHICLES MOVING TOWARDS THE SENSOR (pedestrians and parallel traffic are not detected + immunity filter) 1 Detection of all Targets in Motion 2 Detection of all Targets in Motion + Interference Immunity 3 Low `Pedestrian/Parallel traffic' Rejection + Interference Immunity 4 Medium `Pedestrian/Parallel traffic' Rejection + Interference Immunity 5 High `Pedestrian/Parallel traffic' Rejection + Interference Immunity 6 Extra High `Pedestrian/Parallel traffic' Rejection + Interference Immunity PRESENCE RELAY OUTPUT CONFIGURATION 0 6: ALL MODES IS40 / IS40XL Activates when object is in presence zone. DOOR EXAMPLE First Line ACTIVATION RELAY 0: STANDARD MODE 1: PULSE ON ENTRY IS40 / IS40XL Activates when motion detected. Activates if object motion is detected and then object enters presence zone. Last Line 2: PULSE ON EXIT 3: PULSE ON ENTRY FIRST / LAST LINE see example (left) Activates if object motion is detected and then object exits presence zone. Activates if object motion is detected and then object enters presence zone (first or last line). 4: PULSE ON EXIT FIRST / LAST LINE see example (left) Activates if object motion is detected and then object exits presence zone (first or last line). 5: REMAINS ACTIVE UNTIL PRESENCE ZONE Activates when motion is detected and remains IS CLEARED (regardless of motion) active until the presence zone is cleared. 6: REMAINS ACTIVE UNTIL PRESENCE ZONE IS CLEARED (regardless of motion) Activates when motion is detected and AIR is detected and remains active until the presence zone is cleared. AIR PATTERN SIZE AT 15O SENSOR ANGLE LED red LED green Mounting Height 8 ft 10 ft 11.5 ft 13 ft 16 ft Width* 5 ft 7 ft 7.5 ft 8.5 ft 10 ft Depth* 5 ft 7 ft 7.5 ft 8.5 ft 10 ft Page 8 of 12 * Dimensions are approximate. mounting height increases AIR pattern increases MAXIMUM Mounting Height IS40XL 11.5 ft IS40 16 ft 75.5695.09 IS40 IS40XL 20230908 5 SETUP Launch a setup to make a reference picture. Step out of the detection field and do not leave any tools inside the detection field. Upon power-up, the sensor launches a short setup. IMPORTANT: Perform a functional test for proper operation before leaving the site. POSSIBLE REMOTE CONTROL SETTINGS (presence sensing) FREQUENCY MAX. PRESENCE DETECTION TIME AIR-CURTAIN IMMUNITY TARGET SIZE AIR PATTERN SIZE AB 30 1 2 5 10 20 sec min min min min min 1 hr 1.5 hr 2 hr no learn* * NOT GUARANTEED low normal high The target position within the "AIR" Field is random. AIR PATTERN SIZE AVAILABLE TARGET SIZE DOOR 1 5 2 3 4 DOOR 1 5 2 3 4 DOOR 1 2 3 6 5 DOOR 1 5 2 6 7 6 7 7 6 DOOR 1 5 DOOR 1 5 2 7 DOOR 1 5 2 7 DOOR 1 5 2 7 DOOR 1 5 2 NOTE: TARGET SIZE MUST BE ABLE TO FIT INSIDE THE CHOSEN AIR PATTERN SIZE. IMPORTANT: Always finish an adjustment session by launching a setup (see step 5) and test the proper operation of the installation before leaving the premises. 75.5695.09 IS40 IS40XL 20230908 Page 9 of 12 TROUBLESHOOTING The door never closes and the red LED is on. Objects are present in the AIR detection area. Move objects or reduce automatic learn time. Wait for learn time to expire and/or launch a setup. The door remains closed The sensor power is off. and the LED is OFF. Check the wiring and the power supply. The infrared sensor does The infrared power emission not react. is too low with respect to the mounting height. Lower the mounting height. Step out of the detection field and launch a new setup. Possible target size too large. The door opens for no apparent reason. The sensor detects raindrops or vibrations. Make sure the detection mode is unidirectional. Increase the detection filter value. The sensor is not installed properly. Secure the sensor. In highly reflective environments, Change the antenna angle. the sensor detects objects outside Decrease the field size. of its detection field. Increase the detection filter value. The vehicle detection filter is used, but pedestrians are still detected. The chosen value is not optimal for the application. Increase the detection filter value. Change the sensor angle. Increase the mounting height. The door opens and closes constantly. The sensor is disturbed by the door motion or vibrations caused by the door motion. Make sure the sensor is anchored properly. Make sure the detection mode is unidirectional. Change the sensor angle and/or radar angle. Increase the detection filter value. Reduce the field size. Sporadic presence detections for no reason. The presence detection is disturbed by rain or external environment. Set the AIRcurtain immunity to value 3. Refer to page 7. The sensor is not installed properly. Secure the sensor. The red LED is permanently ON after a setup. The sensor has failed the AIR setup. Step out of the detection field and launch a new setup. The setup lasts more than 30 seconds. The setup is disturbed. Make sure the detection field is clear and launch a new setup. Another sensor is causing interferences. Refer to page 7 and select a different frequency for each sensor. The sensor does not unlock and the red LED flashes quickly. The sensor needs an access code to unlock. Enter the correct access code. If you do not know the access code, refer to page 4 and delete an unknown code. The sensor does not respond to the remote control. The remote control batteries are weak or improperly installed. The remote control is poorly aimed. Check the batteries and change them if necessary. Aim the remote control towards the sensor. The sensor is not powered. Check the power supply of the sensor. Can't find your answer? Visit www.beainc.com or scan QR code for Frequently Asked Questions! Page 10 of 12 75.5695.09 IS40 IS40XL 20230908 ACCESSORIES 10REMOTE 10SPOTFINDER 10BR3X 1024VAC 10INDBRACKET 10MINIBRACKET SINGLE LED TRAFFIC LIGHT DUAL LED TRAFFIC LIGHT COLUMN LIGHT MODULAR COLUMN LIGHT 75.5695.09 IS40 IS40XL 20230908 Page 11 of 12 BEA, INC. INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS BEA, Inc., the sensor manufacturer, cannot be held responsible for incorrect installations or incorrect adjustments of the sensor/device; therefore, BEA, Inc. does not guarantee any use of the sensor/device outside of its intended purpose. BEA, Inc. strongly recommends that installation and service technicians be AAADM-certified for pedestrian doors, IDA-certified for doors/ gates, and factory-trained for the type of door/gate system. Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring that the sensor/device system performance is compliant with local, national, and international regulations, codes, and standards. Once installation or service work is complete, a safety inspection of the door/gate shall be performed per the door/gate manufacturer's recommendations and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry practices. Safety inspections must be performed during each service call examples of these safety inspections can be found on an AAADM safety information label (e.g. ANSI/DASMA 102, ANSI/DASMA 107, UL294, UL325, and International Building Code). Verify that all appropriate industry signage, warning labels, and placards are in place. Tech Support & Customer Service: 1-800-523-2462 General Tech Questions: techservices-us@BEAsensors.com | Tech Docs: www.BEAsensors.com Page 12 of 12 75.5695.09 IS40 IS40XL 20230908