User Guide for Extron models including: DA4 HD 8K L, DA6 HD 8K L, DA6 HD 8K L Distribution Amplifier, DA6 HD 8K L, Distribution Amplifier, Amplifier
28 août 2024 — The Extron DA4 HD 8K L and DA6 HD 8K L distribution amplifiers distribute one HDMI input signal to four or six outputs simultaneously at resolutions up to ...
Aug 28, 2024 — feature EDID Minder Plus, remote control and monitoring via Ethernet, USB, or RS-232, and discrete display control via CEC. For complete instructions, see ...
File Info : application/pdf, 2 Pages, 524.67KB
DocumentDocumentDA4 HD 8K L and DA6 HD 4K L · Setup Guide IMPORTANT NOTE: Go to www.extron.com for the complete user guide, installation instructions, and specifications before connecting the product to the power source. This guide provides basic instructions for an experienced technician to install the DA HD 8K L distribution amplifiers. Overview The Extron DA4 HD 8K L and DA6 HD 8K L distribution amplifiers distribute one HDMI input signal to four or six outputs simultaneously at resolutions up to 8K @ 30 Hz 4:4:4 or 8K @ 60 Hz 4:2:0, and comply with HDMI 2.1 and HDCP 2.2. The DAs also feature EDID Minder® Plus, remote control and monitoring via Ethernet, USB, or RS-232, and discrete display control via CEC. For complete instructions, see the DA HD 8K L Series User Guide at www.extron.com. Front Panel CONFIG e A B INPUT SIGNAL HDCP OUTPUTS 12 34 CD DA4 HD 8K L CONFIG e INPUT 1 OUTPUTS 2 345 6 SIGNAL HDCP DA6 HD 8K L A Power status LED -- Lights when power is applied to the unit. B USB-C Config port -- Connect a PC to this port to configure and monitor the DA via Simple Instruction SetTM (SISTM) or Product Configuration Software (PCS). C Input LEDs -- · Signal LED -- Lights when a TMDS signal is detected on the HDMI input. If the source requires HDCP encryption, this LED may light only when HDCP is authenticated. · HDCP LED -- Lights when the source requires HDCP encryption and it has been authenticated with the HDMI input. D Outputs LEDs -- · HDCP LEDs -- Light when HDCP is authenticated between a DA output and the corresponding sink device. · Signal LEDs -- Light when HPD is detected from the corresponding sink device and a TMDS signal is detected at the input. Rear Panel POWER 12V --A MAX 1 2 3 4 REMOTE RS-232 LAN R OUTPUTS INPUT Tx Rx G AB C D EF OUTPUTS POWER 12V --A MAX REMOTE LAN 1 2 3 4 5 6 RS-232 R INPUT Tx Rx G A Power input -- Connect the provided 12 VDC, 3.0 A power supply to this 2-pole 3.5 mm captive screw port (see the power Attention and diagram to wire the connector on page 2). 1 SECTION AA Smooth Ridges 3/16" (5 mm) Max. A A POWER 12V --A MAX ATTENTION: · Do not connect the power supply before reading the Attention in the Power Supply section of the DA HD 8K L Series User Guide. · Ne branchez pas la source d'alimentation externes avant d'avoir lu les mises en garde dans la section « Power Supply » du DA HD 8K L Series User Guide. B HDMI input (see Rear Panel on page 1) -- Connect a source device to this female HDMI type A input. C HDMI outputs -- Connect up to four or six display devices to these female HDMI type A outputs. D Remote RS-232 port -- Connect the provided 3-pole captive screw connector for SIS configuration, monitoring, and firmware updates (Pin 1 = Tx, Pin 2 = Rx, Pin 3 = Ground). Protocol: 9600 baud, 8 data bits, 1 stop bit, no parity. E LAN port -- Connect to an Ethernet LAN or WAN via this RJ-45 port to control the DA from a remote location. When connected to an Ethernet LAN or WAN, the DA can be accessed and operated from a computer with a standard internet browser. Ethernet connection indicators -- The Link and Activity LEDs indicate the status of the Ethernet connection. · Green Link LED -- Indicates the distribution amplifier is properly connected to an Ethernet LAN. This LED lights steadily. · Amber Activity LED -- Indicates transmission of data packets on the RJ-45 port. This LED flickers as the distribution amplifier communicates. F Reset button -- Use an Extron Tweeker or small screwdriver to press and hold the button while the DA is running or while powering up, for different reset levels. · Press and hold the reset button while applying power to revert to factory default firmware for a single power cycle, but maintain IP settings. · Press and hold the reset button for 3 seconds and again for <1 second within 1 second to reset the unit to factory settings. · Press and hold the reset button for 6 seconds and again for <1 second after the LED blinks twice to reset all IP settings back to factory defaults. · Press and hold reset button for 9 seconds and again for <1 second after the LED blinks 3 times to reset all settings to default except the firmware. Installation 1. Mount the DA in a suitable location with one of the recommended mounting kits (see www.extron.com for mounting options). Follow the instructions provided with the mounting kit. 2. If required, connect a control PC to the USB-C Config port (see Front Panel, B on page 1), Remote RS-232 port (see Rear Panel, D, see the diagram below for wiring), or LAN port (E, see the diagram below, right for wiring). 5 1 96 DB9 Pin Locations Female Computer Pin 2 = Rx Pin 3 = Tx Pin 5 = G Receive Transmit Ground Transmit Receive Ground REMOTE RS-232 Tx Rx G DA HD 8K NOTE: Use PCS to configure EDID Minder, mute the video signal, mute the audio signal, adjust the video color bit depth, or monitor the signal and HDCP status (see the DA HD 8K L Series Help File). 3. Connect the display devices to the rear panel HDMI outputs (see Rear Panel, C) and power them on. Pins: 12345678 Insert Twisted Pair Wires RJ-45 Connector T568A Pin Wire color 1 White-green 2 Green 3 White-orange 4 Blue 5 White-blue 6 Orange 7 White-brown 8 Brown T568B Wire color White-orange Orange White-green Blue White-blue Green White-brown Brown 4. Connect the source device to the rear panel HDMI input (B). NOTE: Use the LockIt® HDMI cable lacing brackets provided to secure the HDMI connectors. 5. Connect the provided 12 VDC, 3.0 A power supply to the 2-pole captive screw inlet (A, see the diagram at the top of the page to wire the connector). 6. Power on the source device. For information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics, see the Extron Safety and Regulatory Compliance Guide on the Extron website. © 2024 Extron -- All rights reserved. www.extron.com All trademarks mentioned are the property of their respective owners. 68-3435-50 Rev. A 08 24 2 Worldwide Headquarters: Extron USA West, 1025 E. Ball Road, Anaheim, CA 92805, 800.633.9876