OMRON HEM-6161 Wrist Blood Pressure Monitor

Instruction Manual

Model: HEM-6161

Document ID: 2829548-5B

Introduction

Thank you for purchasing the OMRON HEM-6161 Wrist Blood Pressure Monitor. This blood pressure monitor is to be worn on your wrist. This new blood pressure monitor uses the oscillometric method of blood pressure measurement. When the cuff inflates, this monitor senses the pressure pulsations of the artery underneath the cuff. The pulses are called oscillometric pulses. The electronic pressure sensor displays a digital reading of blood pressure.

Safety Instructions

Important Safety Information

This instruction manual provides you with important information about the OMRON HEM-6161 Wrist Blood Pressure Monitor. To ensure the safe and proper use of this monitor, READ and UNDERSTAND all of the safety and operating instructions. If you do not understand these instructions or have any questions, contact your local OMRON representative before attempting to use this monitor. For specific information about your own blood pressure, consult with your physician.

Warning: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

Caution: Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury to the user or patient, or cause damage to the equipment or other property.

Battery Handling and Usage

1. Know Your Monitor

1.1 Contents

1.2 Monitor Components

Diagram Description:

1.3 Display and Symbols

Symbol Description
A Systolic blood pressure reading
B Diastolic blood pressure reading
❤️ Heartbeat symbol. Flashes while taking a measurement. Appears if your systolic blood pressure is 135 mmHg or above and/or the diastolic blood pressure is 85 mmHg or above.
✔️ Cuff wrap guide symbol (OK). Appears if the wrist cuff is wrapped around the wrist correctly while taking a measurement. It also appears when viewing past readings.
Cuff wrap guide symbol (loose). Appears if the wrist cuff is not wrapped around the wrist correctly while taking a measurement. It also appears when viewing past readings.
? Memory symbol. Appears when viewing readings stored in the memory.
? Irregular heartbeat symbol. Appears along with readings when an irregular rhythm is detected 2 or more times during a measurement. An irregular heartbeat rhythm is defined as a rhythm that is 25% less or 25% more than the average rhythm detected while your monitor is measuring blood pressure. If it continues to appear, we recommend you to consult with and follow the directions of your physician.
? Battery symbol (low). Flashes when batteries are low.
? Battery symbol (depleted). Appears when batteries are depleted.
? Deflation symbol. Appears during cuff deflation.
[Pulse display / Memory number] Pulse display / Memory number. Pulse rate appears after the measurement. When pressing the [Memory] button, the memory number appears for approximately one second before the pulse rate appears on the display.

Hypertension Guidelines (2013 ESH/ESC*):

Office Home
Systolic Blood Pressure ≥ 140 mmHg ≥ 135 mmHg
Diastolic Blood Pressure ≥ 90 mmHg ≥ 85 mmHg

* European Society of Hypertension (ESH) and European Society of Cardiology (ESC).

2. Preparation

2.1 Installing Batteries

  1. Push down the hook of the battery cover and pull downward.
  2. Insert 2 "AAA" alkaline batteries as indicated in the battery compartment.
  3. Close the battery cover.

Note: When the ? symbol flashes on the display, it is recommended you replace batteries. To replace batteries, turn your monitor off and remove all batteries. Then replace with 2 new alkaline batteries at the same time. Replacing batteries will not delete previous readings. The supplied batteries may have a shorter life than new batteries. Disposal of used batteries should be carried out in accordance with local regulations.

2.2 Blood Pressure Measurement Tips

To help ensure an accurate reading, follow these directions:

Caution: Avoid bathing, drinking alcohol or caffeine, smoking, exercising and eating for at least 30 minutes before taking a measurement. Rest for at least 5 minutes before taking a measurement.

2.3 Applying the Wrist Cuff

Note: Following steps are for applying the wrist cuff to your left wrist. When you take a measurement on your right wrist, apply the wrist cuff using the same steps as on your left wrist. The blood pressure can differ between the right wrist and the left wrist, and the measured blood pressure values can be different. OMRON recommends to always use the same wrist for measurement. If the values between both wrists differ substantially, please check with your physician as to which wrist to use for your measurements.

Caution: Remove tight-fitting, thick clothing and any accessories from your wrist while taking a measurement.

  1. Apply the wrist cuff to your left wrist. Roll up sleeve. Make sure your sleeve is not rolled up too tightly on your arm. This may constrict the flow of blood in your arm.
  2. Put your wrist through the cuff loop. Your palm and monitor display should both face upward.
  3. Position the wrist cuff leaving a clearance of 1 to 2 cm between the cuff and the bottom of your palm.
  4. Wrap the wrist cuff firmly around your wrist. Do not apply over clothing. Check to make sure that there is no gap between your wrist and the cuff.

Note: Make sure the wrist cuff does not cover the protruding part of the wrist bone on the outside of your wrist.

2.4 Sitting Correctly

To take a measurement, you need to be relaxed and comfortably seated in a room with a comfortable temperature. Place your elbow on the table to support your arm.

3. Using Your Monitor

3.1 Taking a Measurement

Note: To stop the measurement, press the [START/STOP] button once to deflate the wrist cuff.

Caution: DO NOT use this monitor with other medical electrical (ME) equipment simultaneously. This may result in incorrect operation of the monitor and/or cause an inaccurate reading. Remain still and DO NOT talk while taking a measurement.

  1. Press the [START/STOP] button. All symbols appear on the display before starting the measurement.
  2. Remain still and do not move or talk until the entire measurement process is completed. As the cuff inflates, your monitor automatically determines your ideal inflation level. This monitor detects your blood pressure and pulse rate during inflation. The ❤️ symbol flashes at every heartbeat.

Note: The ✔️ symbol appears if the wrist cuff is wrapped around the wrist correctly. When the ❌ symbol is displayed, the wrist cuff is not applied correctly. Press the [START/STOP] button to turn your monitor off, then apply the cuff correctly.

After your monitor has detected your blood pressure and pulse rate, the cuff automatically deflates. Your blood pressure and pulse rate are displayed. If either the systolic or the diastolic reading is high (refer to section 1.3), the ❤️ symbol appears.

Measurement Status:

  1. Press the [START/STOP] button to turn your monitor off.

Note: Your monitor will automatically turn off after 2 minutes. Wait 2-3 minutes between measurements. The wait time allows the arteries to decompress and return to their pre-measurement form. You may need to increase the wait time depending on your individual physiological characteristics.

4. Using Memory Function

Your monitor automatically stores up to 30 readings.

4.1 Viewing the Readings Stored in Memory

  1. Press the [Memory] button. The Memory number appears for one second before the pulse rate is displayed. The most recent reading set is numbered "1".

Note: If there are no readings stored in the memory, a specific screen is displayed. If the reading is high (refer to section 1.3), the ❤️ symbol appears. If the memory is full, the monitor will delete the oldest readings.

  1. Press the [Memory] button repeatedly to scroll through the previous readings stored in the memory.

5. Other Settings

5.1 Deleting All Readings Stored in Memory

  1. Press the [Memory] button, then the ? symbol appears.
  2. While holding the [Memory] button down, press and hold the [START/STOP] button for more than 2 seconds.

Note: All readings will be deleted. You cannot partially delete the readings stored in the memory.

6. Error Messages and Troubleshooting

In case of any of the below problems occur during measurement, first check that no other electrical device is within 30cm. If the problem persists, please refer to the table below.

Display / Problem Possible Cause Solution
[Error E1] or cuff does not inflate The wrist cuff is not applied correctly. Air is leaking from the wrist cuff. Apply the wrist cuff correctly, then take another measurement. Refer to section 2.3. Contact local OMRON representative if leak persists.
[Error E3] The wrist cuff is overinflated exceeding 300 mmHg. Do not touch the wrist cuff while taking a measurement.
[Error E4] You move or talk during a measurement. Vibrations disrupt a measurement. Remain still and do not talk during a measurement. Sit correctly.
[Error E5] The pulse rate is not detected correctly. Apply the wrist cuff correctly, then take another measurement. Refer to section 2.3. Remain still and sit correctly during a measurement. If the ? symbol continues to appear, we recommend you to consult with your physician.
[Error Er] The monitor is malfunctioned. Press the [START/STOP] button again. If "Er" still appears, contact local OMRON representative.
? flashes Batteries are low. Replacing all batteries with 2 new alkaline batteries is recommended. Refer to section 2.1.
? or monitor is turned off unexpectedly during a measurement Batteries are depleted. Immediately replace all batteries with 2 new alkaline batteries. Refer to section 2.1.
No power. Nothing appears on the display of the monitor. Batteries are completely depleted. Battery polarities are not properly aligned. Check the battery installation for proper placement. Refer to section 2.1.
Readings appear too high or too low. Blood pressure varies constantly. Many factors including stress, time of day, and/or how you apply the wrist cuff, may affect your blood pressure. Review sections 2.2 - 2.4 and chapter 3.
Any other problems occur. - Press the [START/STOP] button to turn the monitor off, then press it again to take a measurement. If the problem continues, remove all batteries and wait for 30 seconds. Then re-install batteries. If the problem still persists, contact local OMRON representative.

7. Maintenance

7.1 General Maintenance

To protect your monitor from damage, please follow the directions below:

Caution: DO NOT disassemble or attempt to repair this monitor or other components. This may cause an inaccurate reading.

7.2 Storage

Keep your monitor in the storage case when not in use. Store your monitor in a clean, safe location. Do not store your monitor:

7.3 Cleaning

7.4 Calibration and Service

The accuracy of this blood pressure monitor has been carefully tested and is designed for a long service life. It is generally recommended to have the unit inspected every two years to ensure correct functioning and accuracy. Please consult your authorised OMRON dealer or local OMRON representative at the address given on the packaging or attached literature.

8. Specifications

Product description Wrist Blood Pressure Monitor
Model HEM-6161
Display LCD digital display
Cuff pressure range 0 to 299 mmHg
Blood pressure measurement range SYS: 60 to 260 mmHg, DIA: 40 to 215 mmHg
Pulse measurement range 40 to 180 beats / min.
Accuracy Pressure: ±3 mmHg, Pulse: ±5% of display reading
Inflation Automatic by electric pump
Deflation Automatic rapid deflation
Measurement method Oscillometric method
Operation mode Continuous operation
IP classification IP 22
Rating DC3 V 3.0 W
Power source 2 "AAA" alkaline batteries 1.5V
Battery life Approximately 300 measurements (using new alkaline batteries)
Durable period (Service life) 5 years
Operating conditions +10°C to +40°C / 15 to 90% RH (non-condensing) / 800 to 1060 hPa
Storage / Transport conditions -20°C to +60°C / 10 to 90% RH (non-condensing)
Weight Approximately 85 g (excluding batteries)
Dimensions Approximately 84 mm (w) x 62 mm (h) x 21 mm (d) (excluding wrist cuff)
Measurable wrist circumference 13.5 to 21.5 cm
Memory Stores up to 30 readings
Contents Monitor, storage case, 2 "AAA" alkaline batteries, instruction manual
Protection against electric shock Internally powered ME equipment
Cuff Material Nylon and polyester
Applied part Type BF (wrist cuff)
Maximum temperature of the applied part Lower than +48°C

Note: These specifications are subject to change without notice. In the clinical validation study, K5 was used on 85 subjects for determination of diastolic blood pressure. This monitor is clinically investigated according to the requirements of ISO 81060-2:2013. IP classification is degrees of protection provided by enclosures in accordance with IEC 60529. This monitor is protected against solid foreign objects of 12.5 mm diameter and greater such as a finger, and against oblique falling water drops which may cause issues during a normal operation. This device has not been validated for use on pregnant patients.

9. Guidance and Manufacturer's Declaration

CE0197

Symbols Description

[Applied part - Type BF symbol] Applied part - Type BF
[Degree of protection against electric shock symbol] Degree of protection against electric shock (leakage current)
IP XX [Ingress protection symbol] Ingress protection degree provided by IEC 60529
[CE Marking symbol] CE Marking
[Serial number symbol] Serial number
[Temperature limitation symbol] Temperature limitation
[Humidity limitation symbol] Humidity limitation
[Atmospheric pressure limitation symbol] Atmospheric pressure limitation
? Need for the user to consult this instruction manual.
? Indicates the correct positioning for the monitor on the wrist
[Measurable wrist circumference symbol] Measurable wrist circumference
? Battery
DC Direct current

Important information regarding Electro Magnetic Compatibility (EMC)

HEM-6161 manufactured by OMRON HEALTHCARE Co., Ltd. conforms to EN60601-1-2:2015 Electro Magnetic Compatibility (EMC) standard. Further documentation in accordance with this EMC standard is available at www.omronhealthcare-ap.com/emc-information. Refer to the EMC information for HEM-6161 on the website.

Correct Disposal of This Product (Waste Electrical & Electronic Equipment)

This marking shown on the product or its literature, indicates that it should not be disposed of, with other household wastes at the end of its working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this product from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources. Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how they can return this item for environmentally safe recycling. Business users should contact their supplier and check the terms and conditions of the purchase contract. This product should not be mixed with other commercial waste for disposal.

Manufacturer

OMRON HEALTHCARE Co., Ltd. 53, Kunotsubo, Terado-cho, Muko, KYOTO, 617-0002 JAPAN

EU-representative

OMRON HEALTHCARE EUROPE B.V. Scorpius 33, 2132 LR Hoofddorp, THE NETHERLANDS www.omron-healthcare.com

Asia Pacific HQ

OMRON HEALTHCARE SINGAPORE PTE LTD. 438A Alexandra Road, #05-05/08 Alexandra Technopark, Singapore 119967 www.omronhealthcare-ap.com

Production Facility

OMRON HEALTHCARE MANUFACTURING VIETNAM CO., LTD. Binh Duong Province, Vietnam

PDF preview unavailable. Download the PDF instead.

d62493f8d9dc40b8bb35b810f5662986 Acrobat Distiller 10.1.16 (Windows)

Related Documents

Preview OMRON HEM-6181 Wrist Blood Pressure Monitor: User Guide & Safety Instructions
Comprehensive instruction manual for the OMRON HEM-6181 Wrist Blood Pressure Monitor. Learn how to accurately measure blood pressure and pulse rate at home, understand readings, and troubleshoot common issues.
Preview OMRON 5 Series Upper Arm Blood Pressure Monitor BP7200 Instruction Manual
User manual for the OMRON BP7200 5 Series Upper Arm Blood Pressure Monitor, detailing setup, safe usage, measurement, memory functions, troubleshooting, and maintenance for accurate home health monitoring.
Preview OMRON MIT3 Automatic Blood Pressure Monitor Instruction Manual
Comprehensive guide for the OMRON MIT3 Automatic Blood Pressure Monitor, covering setup, usage, maintenance, troubleshooting, and specifications. Learn how to accurately measure blood pressure and pulse rate at home.
Preview OMRON HEM-7142T1 Automatic Blood Pressure Monitor User Manual
Comprehensive guide for the OMRON HEM-7142T1 Automatic Blood Pressure Monitor, covering setup, usage with and without a smartphone, memory functions, troubleshooting, maintenance, and specifications. Learn how to accurately measure blood pressure and heart rate at home.
Preview OMRON HEM-6181 Wrist Blood Pressure Monitor Instruction Manual
Comprehensive instruction manual for the OMRON HEM-6181 Wrist Blood Pressure Monitor, covering setup, usage, safety precautions, troubleshooting, and specifications for accurate home blood pressure monitoring.
Preview OMRON BP7450 10 Series Upper Arm Blood Pressure Monitor Instruction Manual
User manual for the OMRON BP7450 10 Series Upper Arm Blood Pressure Monitor. Learn how to use, set up, and maintain your device for accurate blood pressure and pulse rate measurements at home. Includes safety guidelines and troubleshooting.
Preview OMRON M3 Comfort & X3 Comfort Automatic Blood Pressure Monitor User Manual
Comprehensive user manual for OMRON M3 Comfort (HEM-7155-E) and X3 Comfort (HEM-7155-EO) automatic upper arm blood pressure monitors. Covers setup, operation, safety precautions, troubleshooting, specifications, and warranty information.
Preview OMRON NightView HEM-9601T-E3 Automatic Wrist Blood Pressure Monitor Instruction Manual
Comprehensive guide for the OMRON NightView HEM-9601T-E3 automatic wrist blood pressure monitor. Covers setup, usage, smart device connectivity, memory functions, troubleshooting, maintenance, and specifications for accurate home health monitoring.