Remote Control Specifications

ModelPower SourceSignal Reception RangeEnvironment
RG10R(M2S)/BGEFU1, RG10R(E2S)/BGEFU1, RG10R(F2S)/BGEFU13.0 V (Two AAA/LR03 dry cell batteries)8m23–140°F (-5~ 60°C)

Quick Start Guide

  1. Install Batteries: Slide the rear cover down to expose the battery compartment. Insert batteries, matching the (+) and (-) ends with the symbols in the compartment. Replace the cover.
  2. Select Mode: Press the MODE button to cycle through AUTO, COOL, DRY, HEAT, FAN.
  3. Select Temperature: Use the TEMP ∧ or TEMP ∨ buttons to adjust the desired temperature.
  4. Select Fan Speed: Press the FAN SPEED button to cycle through available speeds (AU, 20%, 40%, 60%, 80%, 100%).
  5. Point Remote at Unit: Aim the remote control at the indoor unit.
  6. Press Power Button: Press the ON/OFF button to turn the air conditioner on or off.

Special Note: Button design may vary slightly. If a button function is not supported by the unit, pressing it will have no effect. In case of discrepancies between the remote control manual and the owner's manual, the owner's manual prevails.

Handling the Remote Control

Battery Installation and Replacement

Slide the rear cover down to expose the battery compartment. Insert batteries, ensuring correct polarity (+/-). Replace the cover.

Battery Precautions

Battery Disposal

Dispose of batteries according to local regulations. Do not dispose of them as unsorted municipal waste.

Remote Control Usage Tips

Remote Control Usage Remarks

This device complies with local regulations. In Canada, it conforms to the CAN ICES-3(B)/NMB-3(B) standard. In the USA, this device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Buttons and Functions

Familiarize yourself with your new air conditioner's remote control. The following provides a brief introduction.

ON/OFF (POWER)
Turns the air conditioner on or off.
TEMP ∧ (Temperature Up)
Increases the temperature by 1°C (1°F) increments. Maximum temperature is 30°C (86°F). Pressing both TEMP ∧ and TEMP ∨ simultaneously for 3 seconds toggles between °C and °F display.
MODE
Cycles through operating modes: AUTO, COOL, DRY, HEAT, FAN. Note: HEAT mode may not be supported by cooling-only units.
ECO/GEAR (ECONOMY/SPEED)
Activates energy-saving modes: ECO, GEAR (75%), GEAR (50%), or returns to the previous setting.
SET
Cycles through functions: Fresh/UV-C Lamp (?), Sleep (?), Follow Me (8), AP Mode (⚙️). The selected symbol will flash; press OK to confirm.
TEMP ∨ (Temperature Down)
Decreases the temperature by 1°C (1°F) increments. Minimum temperature is 16°C (60°F).
OK
Confirms selected functions.
TIMER (MINUTERIE)
Sets the timer to turn the unit on or off.
FAN SPEED
Selects fan speed: AU, 20%, 40%, 60%, 80%, 100%. You can also adjust fan speed by 1% increments using the TEMP ∧ or TEMP ∨ buttons.
BREEZE AWAY
This function prevents direct airflow, creating a gentle, silk-like coolness. Available in COOL, FAN, and DRY modes.
PIVOT
Starts and stops the horizontal louver's movement. For units with vertical louver oscillation, press and hold for 2 seconds to activate automatic vertical louver movement.
CLEAN
Activates/deactivates the Active Clean function (self-cleaning).
LED
Turns the indoor unit's display and beep sound on or off for a comfortable, quiet environment.
Turbo
Allows the unit to reach the set temperature quickly. Press and hold for over 5 seconds in HEAT mode for super heating. Press and hold for over 3 seconds to stop this function.

Model: RG10R(M2S)/BGEFU1, RG10R(E2S)/BGEFU1, RG10R(F2S)/BGEFU1

Remote Control Display Indicators

The following indicators display when the remote is powered on.

Transmission Indicator (LON)
Lights up when the remote sends a signal to the indoor unit.
TIMER ON Indicator
Indicates the timer is set to turn the unit ON.
TIMER OFF Indicator
Indicates the timer is set to turn the unit OFF.
Silence Indicator
Indicates the Silence function is active.
Fan Speed Indicator
Displays the selected fan speed: Silence, LOW, MED, HIGH (ELEVÉ), AUTO. Note: Fan speed cannot be adjusted in AUTO or SEC modes.
Mode Indicators
Displays the current mode: AUTO, COOL, DRY, HEAT, FAN. ECO and GEAR indicators show when these modes are active.
LOCK Indicator
Indicates when the LOCK function is active.
Temperature/Timer/Fan Speed Display
Shows the set temperature, fan speed, or timer setting. Temperature range: 60-86°F (16-30°C). Timer range: 0-24 hours. Fan speed range: AU-100%. This display is blank in FAN mode.
Horizontal Louver Swing Indicator
Indicates the horizontal louver's position.
Vertical Louver Auto Swing Indicator
Indicates automatic vertical louver movement.
Turbo Mode Indicator
Indicates when Turbo mode is active.
Low Battery Indicator
Flashes when the battery is low.

Note: Displayed icons are for illustrative purposes. Only relevant indicators appear during actual operation.

Using Basic Functions

Attention: Ensure the unit is plugged in and power is available before use.

Mode AUTO

  1. Select AUTO mode using the MODE button.
  2. Set the desired temperature using TEMP ∧ or TEMP ∨.
  3. Turn the air conditioner on using the ON/OFF button.

Note: In AUTO mode, the unit automatically selects COOL, FAN, or HEAT based on the set temperature. Fan speed cannot be adjusted in AUTO mode.

Mode COOL (Froid) or HEAT (Chaud)

  1. Select COOL or HEAT mode using the MODE button.
  2. Set the desired temperature using TEMP ∧ or TEMP ∨.
  3. Adjust the fan speed using the FAN SPEED button.
  4. Turn the air conditioner on using the ON/OFF button.

Mode DRY

  1. Select DRY mode using the MODE button.
  2. Set the desired temperature using TEMP ∧ or TEMP ∨.
  3. Turn the air conditioner on using the ON/OFF button.

Note: Fan speed cannot be adjusted in DRY mode as it is automatically controlled.

Mode FAN (Ventilateur)

  1. Select FAN mode using the MODE button.
  2. Adjust the fan speed using the FAN SPEED button.
  3. Turn the air conditioner on using the ON/OFF button.

Note: Temperature cannot be set in FAN mode. No temperature will be displayed on the remote.

Using Other Functions

Timer Setting

The TIMER ON/OFF function allows you to set the duration before the unit automatically turns on or off.

Setting TIMER ON

  1. Press the TIMER button to initiate the ON sequence.
  2. Use the TEMP ∧ or TEMP ∨ buttons to set the desired ON time.
  3. Point the remote at the unit and wait 1 second. The TIMER ON indicator will appear on the remote display.

Setting TIMER OFF

  1. Press the TIMER button to initiate the OFF sequence.
  2. Use the TEMP ∧ or TEMP ∨ buttons to set the desired OFF time.
  3. Point the remote at the unit and wait 1 second. The TIMER OFF indicator will appear on the remote display.

Note: Timer increments are 30 minutes up to 10 hours, then 1-hour increments up to 24 hours. Setting the timer to 0.0 cancels the function. The timer resets to 0.0 after 24 hours.

Swing Function

Press the Swing button to activate/deactivate horizontal louver oscillation (pivoting up and down). Press and hold for over 2 seconds to activate vertical louver oscillation (if available).

Airflow Direction

Continuously press the SWING button to set the airflow direction across five different positions. Press until the desired direction is achieved.

LED Display

Press the LED button to turn the indoor unit's display and beep sound on or off. Press and hold for over 5 seconds to display the actual room temperature. Press and hold again for over 5 seconds to return to the set temperature display.

LOCK Function (VERROUILLAGE)

Press and hold the Clean and Turbo buttons simultaneously for over 5 seconds to activate the lock function. Pressing any button will have no effect. Press and hold both buttons for 2 seconds to deactivate the lock.

Function ECO/GEAR

Press the ECO/GEAR button to cycle through energy-saving modes: ECO → GEAR (75%) → GEAR (50%) → Previous setting. This function is only available in COOL mode.

Function ECO (Sleep)

In COOL mode, pressing ECO automatically sets the temperature to 24°C (75°F) with Auto fan speed for energy saving. If the set temperature is above 24°C (75°F), pressing ECO sets the fan speed to Auto without changing the temperature.

Note: Adjusting mode or temperature below 24°C (75°F) in ECO mode will stop the ECO function. If you are uncomfortable, press ECO again to turn it off.

Function GEAR (Sleep)

Press the ECO/GEAR button to activate GEAR mode: 75% (up to 75% power consumption) or 50% (up to 50% power consumption). The set temperature will reappear after 3 seconds.

Function Silence

Press and hold the Fan button for over 2 seconds to activate/deactivate the Silence function. This may result in reduced cooling/heating capacity due to low compressor frequency.

Function FP

In HEAT mode, press the button twice within one second and set the temperature to 16°C (60°F). The unit operates at high fan speed, and the temperature is automatically set to 80°C/46°F. This function is for heat pump air conditioners only. To cancel, press ON/OFF, Mode, Fan, or Temp buttons, or initiate sleep mode.

Function CLEAN (DELAY)

Press the Clean button to activate the Active Clean function. This technology removes dust, mold, and grease that cause odors by freezing them onto the heat exchanger and then rapidly defrosting the frost. The indoor unit display will show "CL" when active. After 20-45 minutes, the function automatically deactivates.

Function Turbo

In COOL mode, Turbo blows air at the highest setting for rapid cooling. In HEAT mode, Turbo blows air at the highest setting for rapid heating. For units with electric heaters, the electric heater will activate.

Overheating Function

Press and hold the Turbo button for 5 seconds in HEAT or Auto-Heat mode to activate the overheating function. Press and hold for 3 seconds to deactivate. This function improves heating speed at low temperatures. The louver opens to its maximum angle for rapid temperature achievement. Note: Cold air function is deactivated 5 minutes after compressor start, potentially causing low air outlet temperature. Activate or deactivate based on your needs.

Note: "On" or "Off" will display for 3 seconds on the indoor unit display when the overheating function is activated or deactivated. Changing the mode or turning off the unit also stops the overheating function.

Function SET (RÉGLAGE)

Press the SET button to access function settings. Use SET or TEMP ∧/∨ to select the desired function. The selected symbol flashes; press OK to confirm. To cancel, repeat the procedure. Functions include Fresh/UV-C Lamp (?), Sleep (?), Follow Me (8), AP Mode (⚙️). [*] Only units with Fresh or AP function.

Function Fresh/UV-C Lamp

Activates the ionizer or UV-C lamp for air purification.

Function Sleep

Used to reduce energy consumption during sleep for comfortable temperature regulation. This function can only be activated via the remote. Note: SLEEP function is not available in FAN or DRY modes.

Function AP

Select AP mode for wireless setup. To enter AP mode, press the LED button seven times within 10 seconds.

Function Follow Me

The remote measures the ambient temperature and sends the signal to the unit every 3 minutes. This allows the unit to optimize the temperature around you for maximum comfort, especially in AUTO, COOL, or HEAT modes. Press OK for 3 seconds to start/stop the Follow Me memory function. "On" or "OF" will display for 3 seconds. The Follow Me function is not canceled by changing modes or power outages when memory is active.


File Info : application/pdf, 16 Pages, 1.31MB

PDF preview unavailable. Download the PDF instead.

CXP RemoteManual FR

References

Acrobat PDFMaker 25 for Word Adobe PDF Library 25.1.250

Related Documents

Preview Comfort-Aire Century CXP Series Remote Controller Owner Manual
This owner's manual provides comprehensive instructions for operating the Comfort-Aire Century CXP Series remote controller for air conditioning units. It covers basic and advanced functions, button descriptions, screen indicators, and troubleshooting tips.
Preview Comfort Aire SSP Series Remote Controller Owner Manual
This owner's manual provides comprehensive instructions for operating the Comfort Aire SSP Series remote controller, covering basic and advanced functions, button descriptions, and screen indicators for efficient air conditioner use.
Preview Comfort-Aire ZHP Series Remote Controller Owner Manual
This owner's manual provides comprehensive instructions for the Comfort-Aire ZHP Series remote controller, covering specifications, button functions, screen indicators, basic and advanced operations, and troubleshooting.
Preview Comfort-Aire VXP Series Remote Controller Owner Manual
This owner's manual provides comprehensive instructions for operating the Comfort-Aire VXP Series remote controller, including basic and advanced functions, specifications, and troubleshooting tips.
Preview Comfort-Aire WXP Series Remote Controller Owner Manual
Owner's manual for the Comfort-Aire WXP Series remote controller, detailing specifications, button functions, screen indicators, basic and advanced operations, and usage tips.
Preview Manual de Control Remoto Comfort Aire Century Serie VXP
Guía completa para el uso y funciones del control remoto Comfort Aire Century Serie VXP, incluyendo especificaciones, botones, indicadores y modos de operación.
Preview Comfort-Aire Century SAC1318S1A Split System Air Conditioner Parts List
Detailed parts list for the Comfort-Aire Century SE Series SAC1318S1A Split System Air Conditioner, including part codes, names, quantities, and recommendations for storing spare parts.
Preview Comfort-Aire Century SAC1418S1A Split System Air Conditioner Parts List
Detailed parts list and diagram for the Comfort-Aire Century SE Series SAC1418S1A Split System Air Conditioner, including part codes, names, quantities, and visual component descriptions.