FAAC T-MODE Remote Control Instructions
Product Overview
The FAAC T-MODE is a remote control system designed for gate openers and other automated systems. This document provides instructions for its setup, operation, and maintenance.
Key Features and Components
- T-MODE Remote: The primary control unit.
- Programming Switch (P): Used for various programming functions.
- STOP Button: Used to stop motor movement or confirm actions.
- Sun Sensor: An optional sensor that can be integrated with the T-MODE system.
- LED Indicator: Provides status feedback for the remote and sun sensor.
Programming and Operation
1. Memory Storage of the First Remote Control
Procedure: During the SET-UP phase, the motor is activated by a manual push-button. Ensure the push-button is held down until the SET-UP procedure is complete.
- Turn on the power to the motor.
- Press the 'P' button on the remote control.
- Wait for more than 10 seconds.
- Press the 'P' button again.
- Wait for more than 10 seconds.
- Press the 'P' button a third time.
2. Addition of Other Remote Controls
Procedure:
- Select a previously memorized remote control.
- Press the 'P' switch on the new remote control.
- Press the 'STOP' button on the new remote control.
3. Cancellation of a Single Remote Control
Procedure:
- Choose the remote control to be cancelled from the memory.
- Press the 'P' button on the remote control.
- Wait for more than 5 seconds.
- Press the 'STOP' button on the remote control.
4. Cancellation of All Remote Controls
Procedure:
- Disconnect the motor from the power supply.
- Connect the black wire to the brown wire. (If using a step-by-step push-button, simply hold it down without making the connection.)
- Reconnect the motor to the power supply.
- After approximately 5 seconds, the motor will move in both directions for 1 second, indicating that the memory has been completely cleared.
5. Storage of the Preferred Position
Procedure:
- Move the gate to the desired open position and press the 'STOP' button.
- Press and hold the 'STOP' button for 1 second.
- Move the gate to the desired closed position and press the 'STOP' button.
- Press and hold the 'STOP' button for 1 second.
- Press and hold the 'STOP' button for 5 seconds to save the preferred positions.
6. ON-OFF Sun Sensor
Press the sun sensor activation/deactivation button. The display will show the sensor status (ON-OFF). Press the same button again to change the status.
7. Channel Selection
Use the channel selection buttons to cycle through available channels.
8. Battery Substitution
Follow the diagrams to replace the battery in the remote control.
Label Description
The label on the product contains the following information:
- A - Model Identification Code: Unique identifier for the model.
- B - Production Batch Identification Number: Batch number for manufacturing traceability.
- C - Read the Instructions: Indicates that the user manual should be consulted.
- D - Correct Disposal: Instructions for proper disposal of the product according to regulations.
- E - Notified Body Reference: Information about the notified body involved in the product's conformity assessment.
Technical Specifications:
- Work Frequency: 433.92 MHz ±100 KHz
- Battery Type: 3 V CR2340 Lithium
- Intended Use: Gate opener
- Compliance: Conforms to directive 99/05/EEC.
Manufacturer Information
FAAC S.p.A.
Via Benini, 1
40069 Zola Predosa (BO) - ITALY
Tel. 0039.051.61724
www.faacgroup.com