VX4 Submersible Pumps - 4 POLES
VORTEX Series
Submersible pumps, 4 poles (1450 min⁻¹)
Applications
- [Sewage]
- [Civil use]
- [Industrial use]
Performance Overview
Performance Range
- Flow rate up to 900 l/min (54 m³/h)
- Head up to 7 m
Includes
- Power cable length 10 m
Installation and Use
The VX4 series is constructed from thick cast iron, offering exceptional robustness, abrasion resistance, and longevity. Equipped with VORTEX-type impellers, known for their reliability and minimal clogging risk, these pumps are versatile for handling sewage with suspended solids up to 80 mm in diameter, as well as wastewater, rainwater, city sewage, and industrial wastewater. They are suitable for a wide range of applications, including sewers, tunnels, excavations, canals, and underground parking facilities.
Electric Motor
The electric motor is safeguarded by a special three-phase thermal protector, situated within the motor, which activates in case of overheating or abnormal power consumption.
Application Limits
- Depth below water level up to 10 m (with an appropriately sized power cable)
- Liquid temperature up to +40 °C
- Suspended solids transfer:
- up to Ø 50 mm for VX4-10/50
- up to Ø 65 mm for VX4-10/65
- up to Ø 80 mm for VX4-10/80
- Minimum immersion for continuous service: 500 mm
Available Upon Request
- Different voltage requirements, 60 Hz frequency
Patents - Trade Marks - Models
- Registered Community Model No. 003863158-0002
50 Hz | VX4 | Start of production 03.2024
Curves and Performance Data
n = 1450 min⁻¹ | 50 Hz
Performance Curves
The performance curves illustrate the relationship between flow rate (Q) and total manometric head (H) for the VX4 series pumps at 1450 min⁻¹ and 50 Hz. The graph shows:
- X-axis: Flow rate Q (l/min and m³/h)
- Y-axis: Head H (metres and feet)
- Three distinct curves representing models VX4-10/50, VX4-10/65, and VX4-10/80.
- The curves indicate the maximum head achievable at different flow rates for each model.
- Performance curves comply with EN ISO 9906 Grade 3B tolerance limits.
Performance Data Table
| TYPE | POWER (P2) | m³/h | 0 | 6 | 12 | 24 | 30 | 34.5 | 36 | 45 | 54 | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Three-phase | kW | HP | l/min | 0 | 100 | 200 | 400 | 500 | 575 | 600 | 750 | 900 |
| VX4-10/50 | 0.75 | 1 | 7 | 6.4 | 5.8 | 5 | 4 | 2.5 | 1 | |||
| VX4-10/65 | 0.75 | 1 | H metres | 6 | 6 | 5.6 | 5 | 4.4 | 3.8 | 3.3 | 2 | 1 |
| VX4-10/80 | 0.75 | 1 | 5.5 | 5.3 | 4.9 | 4.5 | 3.9 | 3.4 | 2.9 | 1.8 | 1 |
Q = Flow rate | H = Total manometric head
Technical Data
Absorption
| TYPE | VOLTAGE |
|---|---|
| Three-phase | 400 V |
| VX4-10/50 | 2.7 A |
| VX4-10/65 | 2.7 A |
| VX4-10/80 | 2.7 A |
Dimensions and Weight
The diagram illustrates the physical dimensions (a, b, c, h, h1, d, p) of the VX4 submersible pumps and the typical installation setup, including the minimum immersion depth of 500 mm.
| TYPE | Passage of solid bodies | DIMENSIONS mm | kg | ||||||
|---|---|---|---|---|---|---|---|---|---|
| Three-phase | a | b | c | h | h1 | d | p | ||
| VX4-10/50 | Ø 50 mm | 170 | 106 | 193 | 602 | 100 | 55 | 700 | 47.3 |
| VX4-10/65 | Ø 65 mm | 170 | 107 | 196 | 630 | 121 | 70 | 800 | 50.6 |
| VX4-10/80 | Ø 80 mm | 178 | 107 | 210 | 655 | 150 | 85 | 800 | 52.1 |
Port Flange
| TYPE | FLANGE | F | K | D | HOLES | |
|---|---|---|---|---|---|---|
| Three-phase | DN | mm | mm | mm | N° | Ø (mm) |
| VX4-10/50 | 50 (PN10) | 2" | 125 | 150 | 4 | 18 |
| VX4-10/65 | 65 (PN10) | 2½" | 145 | 185 | 8 | 18 |
| VX4-10/80 | 80 (PN10) | 3" | 160 | 200 | 8 | 18 |
Pallet Capacity
| TYPE | NO. OF PUMPS |
|---|---|
| Three-phase | |
| VX4-10/50 | 12 |
| VX4-10/65 | 12 |
| VX4-10/80 | 12 |
Materials and Components
Materials and Components List
The following table details the materials used for each component of the VX4 submersible pump. The diagram shows the numbered components.
| # | Component | Material/Description |
|---|---|---|
| 1 | Pump body | Cast iron with cataphoresis treatment |
| 2 | Impeller | Cast iron VORTEX type with cataphoresis treatment |
| 3 | Motor sleeve | Stainless steel AISI 304 |
| 4 | Motor cover | Cast iron with cataphoresis treatment |
| 5 | Motor shaft | Stainless steel AISI 431 |
| 6 | Double mechanical seal with interposed oil chamber | Seal Details:
|
| 7 | Electric Motor | Three-phase 400 V - 50Hz with winding integrated thermal three-phase motor protection. Insulation: class F. Protection rating: IP X8. |
| 8 | Power cord | 10 metres 'H07 RN-F' type |
Sewage Lifting System VX4 - BC4
Version with Horizontal Delivery and 3/4" Guide Pipes
For VX4/50. Code ASSPVX50. DN 2". Kit consists of: Coupling foot, Guide rail, Support for guide tubes.
Version with Vertical Delivery and 3/4" Guide Pipes
For VX4/50: Code ASSPVX503V, DN 2½". For VX4/65: Code ASSPVX653V, DN 3". For BC4/50: Code ASSVXCF071V, DN 3".
Version with Vertical Delivery and 2" Guide Tubes
For VX4/50: Code ASSPVX50V, DN 3". For VX4/65: Code ASSPVX65V, DN 3". For VX4/80, BC4/50: Code ASSVXCF0705V, DN 3". Kit consists of: Coupling foot complete with counterflange, Guide rail, Support for guide tubes.
Accessories Available for Order
Running Guide
- For VX4 /50 with Ø 3/4" guide tubes: Code ASSFL009
- For VX4 /65 with Ø 3/4" guide tubes: Code ASSFL010
- For BC4 /50 with Ø 3½" guide tubes: Code ASSFL0018
- For VX4 /50 with Ø 2" guide tubes: Code ASSFL050
- For VX4 /65 with Ø 2" guide tubes: Code ASSFL065
- For VX4 /80, BC4 /50 with Ø 2" guide tubes: Code ASSFL072
Complete with screws and seals.
Intermediate Guide Tube Support
- For Ø 3/4" guide tubes: Code 859SV340INTFA
- For guide tubes Ø 2": Code 859SV349INTFA
For reasons of stability, an intermediate support should be interposed: every 2 metres with 3/4" guide pipes (mandatory), every 3 metres with 2" guide tubes (recommended).
Guide Tube (AISI 304 stainless steel)
- 2 metres Ø 3/4" guide tube: Code 54SARTG0052F
- 3 metres Ø 3/4" guide tube: Code 54SARTG0053F
- 6 metres Ø 3/4" guide tube: Code 54SARTG0056F
- 3 metres Ø 2" guide tube: Code 54SARTG0063F
- 6 metres guide tube Ø 2": Code 54SARTG0066F
Dimensions Details
Dimensions (Horizontal delivery version)
Detailed dimensions for the horizontal delivery version are provided below. The diagram illustrates the measurement points (a, b, c, p, h1, h2, h3, i1, i2, i3, i4, i5, Øg, Øm, Øn).
| TYPE | Solid bodies | PORT | DIMENSIONS mm | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| mm | DN | a | b | c | p | h1 | h2 | h3 | i1 | i2 | i3 | i4 | i5 | Øg | Øm | Øn | |
| VX4/50 | Ø 50 | 2" | 214 | 61 | 17 | 400 | 30 | 165 | 130 | 85 | 94 | 16 | 40 | 50 | 3/4" | 12 | 11 |
Dimensions (Version with VERTICAL delivery)
Detailed dimensions for the vertical delivery version are provided below, with separate tables for 3/4" and 2" guide tubes. The diagrams illustrate the measurement points.
Version with 3/4" guide tubes
| TYPE | Solid bodies | PORT | DIMENSIONS mm | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| mm | DN | a | b | c | d | e | p | h1 | h2 | h3 | i1 | i2 | i3 | i4 | i5 | Øg | Øm | Øn | Ør | ||
| VX4/50 | Ø 50 mm | 2½" | 211 | 52 | 125 | 165 | 506 | 28 | 164 | 216 | 120 | 72 | 62 | 3 | 50 | 3/4" | 14 | 11 | 18 | ||
| VX4/65 | Ø 65 mm | 3" | 213 | 61 | 69 | 150 | 190 | 537 | 48 | ||||||||||||
| BC4/50 | Ø 50 mm | 3" | 222 | 553 | 19 | ||||||||||||||||
Version with 2" guide tubes
| TYPE | Solid bodies | PORT | DIMENSIONS mm | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| mm | DN | a | b | c | d | e | p | h1 | h2 | h3 | i1 | i2 | i3 | i4 | i5 | i6 | Øg | Øm | Øn | Ør | |
| VX4/50 | Ø 50 mm | 3" | 319 | 706 | 107 | ||||||||||||||||
| VX4/65 | Ø 65 mm | 3" | 86 | 95 | 160 | 200 | 264 | 392 | 250 | 150 | 34 | 80 | 2" | 22 | 13.5 | 18 | |||||
| VX4/80 | Ø 80 mm | 3" | 328 | 714 | 57 | ||||||||||||||||
| BC4/50 | Ø 50 mm | 3" | 328 | 714 | 57 | ||||||||||||||||