Aquatec® Step User Manual

1 General

This user manual contains important information about the handling of the product. To ensure safety when using the product, read the user manual carefully and follow the safety instructions. If you find that the font size in the printed document is difficult to read, you can download the PDF version from the website.

Invacare reserves the right to alter product specifications without further notice.

In case of a serious incident with the product, you should inform the manufacturer and the competent authority in your country.

1.1 Introduction

This user manual contains important information about the handling of the product. To ensure safety when using the product, read the user manual carefully and follow the safety instructions. If you find that the font size in the printed document is difficult to read, you can download the PDF version from the website.

Invacare reserves the right to alter product specifications without further notice.

1.2 Warranty Information

Invacare provides a manufacturer's warranty for the product in accordance with its General Terms and Conditions of Business in the respective countries. Warranty claims can only be made through the provider from whom the product was obtained.

1.3 Compliance

This CE- and UKCA-marked medical device conforms to: EU Medical Device Regulation, UK Medical Device Regulation, ISO 13485, ISO 14971, REACH, EN 12182 and related standards.

1.4 Service life

The expected service life of this product is three years when used in accordance with safety instructions and intended use, as stated in this manual. The effective service life can vary according to frequency and intensity of use.

1.5 Limitation of Liability

Invacare accepts no liability for damage arising from:

  • Non-compliance with the user manual
  • Incorrect use
  • Natural wear and tear
  • Incorrect assembly or set-up
  • Unauthorised modifications and/or use of unsuitable spare parts

2 Safety

2.1 Safety Information

⚠️ WARNING! Risk of Serious Injury or Damage
Improper use of this product may cause injury or damage.

  • If you are unable to understand the warnings, cautions or instructions, contact a health care professional or provider before attempting to use this equipment.
  • Do not use this product or any available optional equipment without first completely reading and understanding these instructions and any additional instructional material.

⚠️ WARNING! Risk of Falling!

  • Before every use, check the product for damage and ensure that it is securely assembled.
  • Do not use if defective.
  • Do not make any unauthorised alterations or modifications to the product.
  • Do not move or displace the product under load or during use.
  • Only use the product on level ground.
  • Only use accessories and options intended for this product.

2.2 Labels and Symbols on the Product (Fig. 3)

The identification label is attached to the underside of the product.

A Manufacturer G Production date
B UK Conformity Assessed H Unique Device Identifier
C European Conformity I Medical Device
D Lot number J Reference number
E Read user manual K Product designation
F Maximum user weight

3 Product Overview

3.1 Intended use

This stepping aid is intended as an aid to enter into or get out of a bathtub for persons with mobility limitations.

Indication: If used without an assistant, the users must be able to keep their own balance. There are no contraindications known when using the product as intended. For the maximum user weight, see 7 Technical Data.

3.2 Scope of Delivery

The scope of delivery is shown in Figure 1. Figure 1 depicts the Aquatec Step with its overall dimensions: approximately 410 mm in length and 310 mm in width, with a height of 165 mm. The diagram indicates materials such as PVC, PP, and TPE.

4 Setup

For removing or installing the non-slip cover A, refer to Figure 2. Figure 2 illustrates the product with parts labeled A and B, likely referring to the non-slip cover and fastening buttons respectively.

⚠️ WARNING! Risk of Slipping
Make sure that all 10 fastening buttons B are securely fastened before using the product.

5 Maintenance

5.1 General Maintenance Information

This product is maintenance-free, provided that the cleaning and disinfection instructions are adhered to.

5.2 Cleaning and Disinfection

General Safety Information

❗ CAUTION! Risk of Contamination
Take precautions for yourself and use appropriate protective equipment.

ℹ️ NOTICE! Wrong fluids or methods can harm or damage the product.

  • All cleaning agents and disinfectants used must be effective, compatible with one another and must protect the materials they are used to clean.
  • Never use corrosive fluids (alkalines, acid etc.) or abrasive cleaning agents. We recommend an ordinary household cleaning agent such as dishwashing liquid.
  • Never use a solvent (cellulose thinner, acetone etc.) that changes the structure of the plastic or dissolves the attached labels.

For cleaning and disinfection in clinical or long-term care environments, follow your in-house procedures.

Cleaning Intervals

ℹ️ NOTICE! Regular cleaning and disinfection enhances smooth operation, increases the service life and prevents contamination.

Clean and disinfect the product:

  • before first use,
  • regularly while it is in use,
  • when it has been in contact with any body fluids.

Cleaning

  1. Remove detachable parts.
  2. Clean all parts by wiping down all generally accessible surfaces.
  3. Machine-wash the cover at max. 60 °C.
  4. Dry the parts with a cloth.

Disinfection Instructions

Method: Follow the application notes for the used disinfectant and wipe-disinfect all accessible surfaces.

Disinfectant: Ordinary household disinfectant.

Drying: Allow the product to air-dry.

6 After Use

6.1 Reconditioning

This product is suitable for reuse. To recondition the product for a new user, carry out the following actions:

  • Inspection
  • Cleaning and disinfection

For detailed information, see 5 Maintenance.

Make sure that the user manual is handed over with the product.

6.2 Disposal

Disassemble the product and its components, so the different materials can be separated and recycled individually.

The disposal and recycling of used products and packaging must comply with the laws and regulations for waste handling in each country. Contact your local waste management company for information.

7 Technical Data

7.1 Weights

Product weight: 1.5 kg
Max. user weight: 150 kg

All product components do not contain natural rubber latex.

7.2 Environmental Parameters

Operating Conditions

Ambient temperature 10 - 40 °C
Relative humidity 15% - 93%, non-condensing

Storage and Shipping Conditions

Ambient temperature 0 - 40 °C
Relative humidity 30% - 75%, non-condensing
Models: Aquatec Step Stepping Aid, Aquatec Step, Stepping Aid, Aid

File Info : application/pdf, 16 Pages, 1.13MB

PDF preview unavailable. Download the PDF instead.

DTEC009312 15634~F-print

References

PDFlib PDI 8.0.2p1 (Win32) Arbortext Publishing Engine

Related Documents

Preview Aquatec Trans User Manual: Invacare Transfer Board for Bath Lifts
This user manual provides essential information for the Invacare Aquatec Trans transfer board, covering safe setup, usage, maintenance, cleaning, and technical specifications. Learn how to safely assist individuals with mobility limitations during bath transfers.
Preview Invacare Rollator Assembly, Installation, and Operating Instructions
Comprehensive guide for Invacare Rollators, covering assembly, safe operation, maintenance, and warranty information. Includes patient height specifications and troubleshooting tips.
Preview Invacare ISA Patient Lifters: Compact, Standard, Plus, Xplus - User Guide
Concise guide to Invacare ISA patient lifters (Compact, Standard, Plus, Xplus) covering features, operation, and weight capacities. Learn about safe patient transfers with Invacare.
Preview Invacare Action NG Wheelchair - Features, Specifications, and Options
Detailed information on the Invacare Action NG wheelchair, including features, product characteristics, available options, technical specifications, and pricing. This guide covers various configurations, seating options, armrests, footrests, and accessories to customize the wheelchair.
Preview Invacare Erivo R10 Mobility Scooter Prescription Form
Prescription form for the Invacare Erivo R10 mobility scooter, detailing standard features, pricing, and options for Motability Retail customers.
Preview Invacare Action 5 Wheelchair - Features, Specifications, and Options
Detailed product information for the Invacare Action 5 wheelchair, including features, technical specifications, available options, and pricing. Explore customization possibilities for a personalized mobility solution.
Preview Invacare Action NG XLT Wheelchair - Features, Specifications, and Options
Detailed information on the Invacare Action NG XLT wheelchair, including features, technical specifications, available options, and pricing. Explore customization for your wheelchair with unique special manufacturing.
Preview Invacare Rea Azalea Assist Max Wheelchair - Product Information and Options
Detailed product information for the Invacare Rea Azalea Assist Max wheelchair, including features, specifications, pricing, and available options. Learn about customization and accessories for this advanced mobility solution.