Owner's Manual for Altronix models including: T2MK3F4Q, T2MK3F4DQ, TROVE1M1, TROVE2M2, TROVE3M3, TMV2, TM250, TM400, T2MK3F4Q Lore Plus Technology, T2MK3F4Q, Lore Plus Technology, Plus Technology, Technology

[PDF] Trove streamlines access control design and deployment - Altronixaltronix.com › pdf › catalogs

Trove streamlines access control design and deployment

12 juil. 2024 — Managed Fuse Protected Models. Managed PTC Protected Models. T2MK3F4Q. eFlow6NB, LINQ2, ACM4, VR6, PDS8. T2MK3F4DQ. eFlow6NB, LINQ2, ACM4CB, VR6, PDS8CB.20 pages


File Info : application/pdf, 21 Pages, 18.77MB

PDF preview unavailable. Download the PDF instead.

TB LenelS2OnGuard
STREAMLINE DESIGN & DEPLOYMENT

718.567.8181 | info@altronix.com

1

Easily combine Altronix power and accessories with access controllers from the industry's leading manufacturers - Reducing installation and labor costs!

· Trove streamlines access control design and deployment, increasing profits and ROI.
· Removable backplanes allow you to configure and test prior to on-site installation.
· Trove enclosures are available in different sizes and configurations to meet your project scope ­ including wall mount, rack mount and outdoor models.
· Pre-configured kits are available with power distribution, finger duct and wire assemblies.
· Combine both access and intrusion modules for various brands - all in one enclosure, for added value!
· Optional LINQTM Networked Power Management Technology allows you remotely monitor, control and report power/diagnostics, streamlining service and maintenance operations by leveraging the network.
· Altronix products are TAA & NDAA compliant
· Our free online Trove System Design tool simplifies the design and product selection process: www.altronix.com/system_design_tools/trove
2

718.567.8181 | info@altronix.com

Altronix®

Enclosure Options

TROVE1 - Knockouts accommodate up to 1.5" conduit - Accommodates two (2) 12VDC/7AH batteries Dimensions: 18" H x 14.5" W x 4.625" D
TROVE2 - Knockouts accommodate up to 2.0" conduit - Accommodates four (4) 12VDC/12AH batteries Dimensions: 27.25" H x 21.75" W x 6.5" D
TROVE3 - Knockouts accommodate up to 2.0" conduit - Accommodates four (4) 12VDC/12AH batteries Dimensions: 36.12" H x 30.12" W x 7.06" D

TROVE OUTDOOR - NEMA 4/4X, IP66-11Rated Outoor Enclosure - Lockable latches and integral flanges
simplify mounting Dimensions: 17.53" H x 15.3" W x 6.67" D
718.567.8181 | info@altronix.com

TROVE RACK MOUNT - 2U, 24" or 36" deep rack drawer on extendable rails - Integrated Z bracket on rear facilitates wiring Dimensions: 3.375" H x 19" W x 24" D
3

Altronix®

Access and Power Integration

OnGuard Platform

Altronix Model

Description

System Capacity

Compatible LenelS2 OnGuard Models

Trove1 Series - Accommodates Altronix Power and Distribution with Controllers

TROVE1M1 TM1

Enclosure + Backplane Backplane only

8-Doors

Trove2 Series - Accommodates Altronix Power and Distribution with Controllers

TROVE2M2 TM2

Enclosure + Backplane Backplane only

12-Doors

Trove3 Series - Accommodates Altronix Power and Distribution with Controllers

TROVE3M3 TM3

Enclosure + Backplane Backplane only

24-Doors

LNL-2220, LNL-4420, LNL-1100, LNL-1200, LNL-3300, LNL-8000, LNL-2210, LNL-1300, LNL-1300e

Trove2 and Trove3 Door Backplane only

TMV2

Door Backplane only

12-Doors

LNL-2220, LNL-4420, LNL-1100, LNL-1200, LNL-3300, LNL-8000, LNL-2210, LNL-1300, LNL-1300e

TM250

Enclosure

Compact Mercury Enclosures 2-Doors

LNL-2210, LNL-1300, LNL-1300e

TM400

Enclosure

2-Doors

LNL-2220, LNL-4420, LNL-1100, LNL-1200, LNL-3300, LNL-8000, LNL-2210, LNL-1300, LNL-1300e

TM250 2-Door Access System

TM400 2-Door Access System

4

718.567.8181 | info@altronix.com

Altronix®

Access and Power Integration

Altronix Model

Description Trove1 Pre-configured Kits

Fuse Protected Models

PTC Protected Models

T1MK1F4

eFlow4NB, ACM4, VR6

T1MK1F4D

eFlow4NB, ACM4CB, VR6

T1MK1F4S

eFlow4NB, ACM4, VR6, PDS8

Managed Fuse Protected Models

T1MK1F4SD

eFlow4NB, ACM4CB, VR6, PDS8CB

Managed PTC Protected Models

T1MK1F4Q eFlow4NB, LINQ2, ACM4, VR6, PDS8 T1MK1F4DQ

eFlow4NB, LINQ2, ACM4CB, VR6

T1MK1F4SQ eFlow4NB, LINQ2, ACM8, VR6, PDS8 T1MK1F4SDQ eFlow4NB, LINQ2, ACM4CB, VR6, PDS8CB 220VAC units available upon request, add suffix "V" (T1MK1F4V)

OnGuard Platform

System Compatible LenelS2

Capacity

OnGuard Models

4-Doors 4-Doors

LNL-2220, LNL-4420, LNL-1100, LNL-1200,
LNL-3300, LNL-8000, LNL-2210, LNL-1300, LNL-1300e

T1MK1F4D 4-Door Access System with Power

T1MK1F4SQ 4-Door Access System Managed with Power

718.567.8181 | info@altronix.com

5

Altronix®

Access and Power Integration

OnGuard Platform

Altronix Model

Description

Altronix Model Trove2 Pre-configured Kits

Description

System Compatible LenelS2 Capacity OnGuard Models

T2MK3F4

Fuse Protected Models eFlow6NB, ACM4, VR6, PDS8

T2MK3F4D

PTC Protected Models eFlow6NB, ACM4CB, VR6, PDS8CB

4-Doors

T2MK3F8

eFlow6NB, ACM8, VR6, PDS8

T2MK7F8

eFlow104NB, ACM8, VR6, PDS8

Managed Fuse Protected Models

T2MK3F8D T2MK7F8D

eFlow6NB, ACM8CB, VR6, PDS8CB
eFlow104NB, ACM8CB, VR6, PDS8CB Managed PTC Protected Models

8-Doors

T2MK3F4Q

eFlow6NB, LINQ2, ACM4, VR6, PDS8 T2MK3F4DQ

eFlow6NB, LINQ2, ACM4CB, VR6, PDS8CB

4-Doors

T2MK3F8Q T2MK7F8Q

eFlow6NB, LINQ2, ACM8, VR6, PDS8 T2MK3F8DQ

eFlow6NB, LINQ2, ACM8CB, VR6, PDS8CB

eFlow104NB, LINQ2,ACM8, VR6, PDS8 T2MK7F8DQ

eFlow104NB, LINQ2, ACM8CB, VR6, PDS8CB

Trove2 Series Pre-configured Kits (Utilizing TMV2 Door Backplane)

8-Doors

Fuse Protected Models

PTC Protected Models

T2MK75F16 eFlow102NB, eFlow104NB, 2-ACM8, PD16W T2MK75F16D

T2MK77F16

2-eFlow104NB, 2-ACM8, VR6, PDS8

Managed Fuse Protected Models

T2MK77F16D

eFlow102NB, eFlow104NB, 2-ACM8CB, PD16WCB 16-Doors
2-eFlow104NB, 2-ACM8CB, VR6, PDS8CB Managed PTC Protected Models

LNL-2220, LNL-4420, LNL-1100, LNL-1200, LNL-3300, LNL-8000, LNL-2210, LNL-1300, LNL-1300e

T2MK75F16Q

eFlow102NB, eFlow104NB, LINQ2, 2-ACM8, PD16W

T2MK75F16DQ

eFlow102NB, eFlow104NB, LINQ2, 2-ACM8CB, PD16WCB

16-Doors

T2MK77F16Q 2-eFlow104NB, LINQ2 ,2-ACM8, VR6, PDS8 T2MK77F16DQ 2-eFlow104NB, LINQ2, 2-ACM8CB, VR6, PDS8CB 220VAC units available upon request, add suffix "V" (T2MK3F4DV)

T2MK7F8 8-Door Access System with Managed Power

6

718.567.8181 | info@altronix.com

Altronix®

Access and Power Integration

Altronix Model

Description

Altronix Model

Description

Trove3 Series Pre-configured Kits

Fuse Protected Models

PTC Protected Models

System Capacity

T3MK75F16

eFlow102NB, eFlow104NB, 2-ACM8, PD8UL, RSB2

T3MK75F16D

eFlow102NB, eFlow104NB, 2-ACM8CB, PD8ULCB, RSB2

T3MK77F16 T3MK75F16S

2-eFlow104NB, 2-ACM8, 2-PD8UL, RSB2
eFlow102NB, eFlow104NB, 2-ACMS8, PDS8, RSB2

T3MK77F16D T3MK75F16SD

2-eFlow104NB, 2-ACM8CB, 2-PD8ULCB, RSB2
eFlow102NB, eFlow104NB, 2-ACMS8CB, PDS8CB, RSB2

16-Doors

T3MK77F16S

2-eFlow104NB, 2-ACMS8, 2-PDS8, 2-VR6, RSB2

T3MK77F16SD

2-eFlow104NB, 2-ACMS8CB, 2-PDS8CB, 2-VR6, RSB2

220VAC units available upon request, add suffix "V" (T3MK75F16V)

OnGuard Platform
Compatible LenelS2 OnGuard Models
LNL-2220, LNL-4420, LNL-1100, LNL-1200,
LNL-3300, LNL-8000, LNL-2210, LNL-1300, LNL-1300e

T3MK75F16D 16-Door Access System with Power

718.567.8181 | info@altronix.com

7

Altronix

OnGuard Platform

Pre-wired Access and Power Integration Kits

Altronix Model

Description

Altronix Model

Description

System Capacity

Compatible LenelS2 OnGuard Models

Trove2 Series - Includes Power Distribution, Wire Assemblies for Controllers and Finger-duct for Wire Management

Fuse Protected Models

PTC Protected Models

T2M7XK1

Trove2M2 with

T2M7XK1D

Trove2M2 with

8-Doors

1-LNL-2220 and 3-LNL-1320

T2M7XK2

eFlow104NB, ACMS8, VR6,

T2M7XK2D

eFlow104NB, ACMS8CB, VR6,

6-Doors

1-LNL-3300 and 3-LNL-1320

T2M7XK3

PDS8, RSB1

T2M7XK3D

PDS8CB, RSB1

8-Doors

4-LNL-1320

Managed Trove2 Series - Includes Power Distribution, Wire Assemblies for Controllers and Finger-duct for Wire Management

Fuse Protected Models

PTC Protected Models

T2M7XK1Q

Trove2M2 with

T2M7XK1DQ

Trove2M2 with

T2M7XK2Q eFlow104NB, LINQ8ACM, VR6, T2M7XK2DQ

eFlow104NB, LINQ8ACMCB, VR6,

T2M7XK3Q

LINQ8PD, RSB1

T2M7XK3DQ

LINQ8PDCB, RSB1

220VAC units available upon request, add suffix "V" (T2M7XK1V)

8-Doors 6-Doors 8-Doors

1-LNL-2220 and 3-LNL-1320 1-LNL-3300 and 3-LNL-1320
4-LNL-1320

Custom Wire Assemblies Factory installed and include terminal block connections for Mercury hardware for ease of installation

Removeable Backplane For ease of deployment

Altronix Power Distribution Supporting the Mercury Hardware

Finger Duct Option For wire management

Controller boards sold separately

Backup Batteries Ample room in enclosure for batteries

8

718.567.8181 | info@altronix.com

Altronix

OnGuard Platform

Pre-wired Access and Power Integration Kits

Altronix Model

Description

Altronix Model

Description

System Capacity

Compatible LenelS2 OnGuard Models

Trove3 Series - Includes Power Distribution, Wire Assemblies for Controllers and Finger-duct for Wire Management

Fuse Protected Models

PTC Protected Models

T3M77XK1 Trove3M3 with 2-eFlow104NB, T3M77XK1D

Trove3M3 with 2-eFlow104NB,

16-Doors

1-LNL-2220 and 7-LNL-1320

T3M77XK2

2-ACMS8, 2-VR6,

T3M77XK2D

2-ACMS8CB, 2-VR6,

14-Doors

1-LNL-3300 and 7-LNL-1320

T3M77XK3

2-PDS8, RSB2

T3M77XK3D

2-PDSCB, RSB2

16-Doors

8-LNL-1320

T3M7724XK1

Trove3M3 with TMV2

T3M7724XK1D

Trove3M3 with TMV2

24-Doors

1-LNL-2220 and 11-LNL-1320

T3M7724XK2 2-eFlow104NB, 2-ACMS12, T3M7724XK2D

2-eFlow104NB, 2-ACMS12CB,

22-Doors

1-LNL-3300 and 11-LNL-1320

T3M7724XK3

2-PDS8, RSB2

T3M7724XK3D

2-PDS8CB, RSB2

24-Doors

12-LNL-1320

Managed Trove3 Series - Includes Power Distribution, Wire Assemblies for Controllers and Finger-duct for Wire Management

Fuse Protected Models

PTC Protected Models

T3M77XK1Q Trove3M3 with 2-eFlow104NB, T3M77XK1DQ

Trove3M3 with 2-eFlow104NB,

T3M77XK2Q

2-LINQ8ACM, 2-VR6,

T3M77XK2DQ

2-LINQ8ACMCB, 2-VR6,

T3M77XK3Q

2-LINQ8PD, RSB2

T3M77XK3DQ

2-LINQ8PDCB, RSB2

220VAC units available upon request, add suffix "V" (T2M7XK1V)

16-Doors 14-Doors 16-Doors

1-LNL-2220 and 7-LNL-1320 1-LNL-3300 and 7-LNL-1320
8-LNL-1320

Custom Wire Assemblies Factory installed and include terminal block connections for Mercury hardware for ease of installation

Altronix Power Distribution Supporting the Mercury Hardware

718.567.8181 | info@altronix.com

Removeable Backplane For ease of deployment

Controller boards sold separately

Finger Duct Option For wire management
Backup Batteries Ample room in enclosure for batteries
9

Altronix

OnGuard Platform

Pre-wired Access and Power Integration Kits

Altronix Model

Description

Altronix Model

Description

System Capacity

Compatible MERCURY* Models

Trove1 Series - Includes Power Distribution, Wire Assemblies for Controllers and Wire Magnets for Wire Management

Fuse Protected Models

PTC Protected Models

T1M1CK1 T1M1CK2 T1M1CK3

T1M1CK1D

Trove1M1 with eFlow4NB,ACM4, VR6, PDS8, RSB1

T1M1CK2D

T1M1CK3D

Trove1M1 with eFlow4NB, ACM4CB, VR6, PDS8CB, RSB1

4-Doors 2-Doors 4-Doors

1-LNL-2220 and 1-LNL-1320 1-LNL-3300 and 1-LNL-1320
2-LNL-1320

Managed Trove1 Series - Includes Power Distribution, Wire Assemblies for Controllers and Wire Magnets for Wire Management

Fuse Protected Models

PTC Protected Models

T1M1CK1Q T1M1CK2Q T1M1CK3Q

Trove1M1 with eFlow4NB, VR6, LINQ8PD, RSB1

T1M1CK1DQ T1M1CK2DQ T1M1CK3DQ

Trove1M1 with eFlow4NB, VR6, LINQ8PDCB, RSB1

4-Doors 2-Doors 4-Doors

1-LNL-2220 and 1-LNL-1320 1-LNL-3300 and 1-LNL-1320
2-LNL-1320

220VAC units available upon request, add suffix "V" (T1M7XK1V)

Altronix Power Distribution Supporting the Mercury Hardware
Removeable Backplane For ease of deployment
Wire Magnet Option For wire management

10

718.567.8181 | info@altronix.com

Altronix

OnGuard Platform

Pre-wired Access and Power Integration Kits

Altronix Model

Description

Altronix Model

Description

System Capacity

Compatible MERCURY* Models

Trove2 Series - Includes Power Distribution, Wire Assemblies for Controllers and Wire Magnets for Wire Management

T2M7CK1 T2M7CK2 T2M7CK3

Fuse Protected Models

PTC Protected Models

Trove2M2 with eFlow104NB, ACMS8, VR6, PDS8, RSB1

T2M7CK1D T2M7CK2D T2M7CK3D

Trove2M2 with eFlow104NB, ACMS8CB, VR6, PDS8CB, RSB1

8-Doors 6-Doors 8-Doors

1-LNL-2220 and 3-LNL-1320 1-LNL-3300 and 3-LNL-1320
4-LNL-1320

Trove3 Series - Includes Power Distribution, Wire Assemblies for Controllers and Wire Magnets for Management

Fuse Protected Models

PTC Protected Models

T3M77CK1 T3M77CK2 T3M77CK3

T3M77CK1D

Trove3M3 with 2-eFlow104NB, 2-ACMS8, 2-VR6, 2-PDS8, RSB2

T3M77CK2D

T3M77CK3D

Trove3M3 with 2-eFlow104NB, 2-ACMS8CB, 2-VR6, 2-PDSCB, RSB2

220VAC units available upon request, add suffix "V" (T2M7CK1V)

16-Doors 14-Doors 16-Doors

1-LNL-2220 and 7-LNL-1320 1-EP(LP)2500 and 7-LNL-1320
8-LNL-1320

Removeable Backplane For ease of deployment

Optional Door Backplane For additional controller boards (Model: TMV2, fits Trove2 and Trove3)
Altronix Power Distribution Supporting the Mercury Hardware

Wire Magnet Option For wire management

Controller boards sold separately
718.567.8181 | info@altronix.com

Backup Batteries Ample room in enclosure for batteries
11

Altronix

OnGuard Platform

Pre-wired Access and Power Integration Kits

Altronix Model

Description

Altronix Model

Description

System Capacity

Compatible MERCURY* Models

Managed Trove2 Series - Includes Power Distribution, Wire Assemblies for Controllers and Wire Magnets for Wire Management

Fuse Protected Models

PTC Protected Models

T2M7CK1Q T2M7CK2Q T2M7CK3Q

T2M7CK1DQ

Trove2M2 with eFlow104NB, LINQ8ACM, VR6, LINQ8PD, RSB1

T2M7CK2DQ

T2M7CK3DQ

Trove2M2 with eFlow104NB, LINQ8ACMCB, VR6, LINQ8PDCB, RSB1

8-Doors 6-Doors 8-Doors

1-LNL-2220 and 3-LNL-1320 1-LNL-3300 and 3-LNL-1320
4-LNL-1320

Managed Trove3 Series - Includes Power Distribution, Wire Assemblies for Controllers and Wire Magnets for Management

Fuse Protected Models

PTC Protected Models

T3M77CK1Q Trove3M3 with 2-eFlow104NB, T3M77CK1DQ

Trove3M3 with 2-eFlow104NB,

T3M77CK2Q 2-LINQ8ACM, 2-VR6, 2-LINQ8PD, T3M77CK2DQ 2-LINQ8ACMCB, 2-VR6, 2-LINQ8PDCB,

T3M77CK3Q

RSB2

T3M77CK3DQ

RSB2

220VAC units available upon request, add suffix "V" (T2M7CK1V)

16-Doors 14-Doors 16-Doors

1-LNL-2220 and 7-LNL-1320 1-EP(LP)2500 and 7-LNL-1320
8-LNL-1320

Removeable Backplane For ease of deployment

Optional Door Backplane For additional controller boards (Model: TMV2, fits Trove2 and Trove3)
Altronix Power Distribution Supporting the Mercury Hardware

Wire Magnet Option For wire management

Controller boards sold separately
12

Backup Batteries Ample room in enclosure for batteries
718.567.8181 | info@altronix.com

Altronix®

af

OnGuard Platform

Maximum-density Access and Power Integration

Altronix Model

Description

System Capacity

Compatible MERCURY Models

Trove3 Series with Angled Brackets for high capacity systems

TROVE3MBK3 TMB3

Enclosure + Backplane with 36-BR3M Angled Brackets Backplane only

24-Doors (with power) 36-Doors (controllers only)

LNL-2220, LNL-4420, LNL-1100, LNL-1200, LNL-3300, LNL-8000

Altronix Model
T3MB755K1 T3MB777K1

Description

Altronix Model

Description

System Compatible MERCURY

Capacity

Models

Trove3 Series - Includes Power Distribution, Wire Assemblies for Controllers and Wire Magnets for Management

Fuse Protected Models

PTC Protected Models

Trove3MBK3 with 1-eFlow104NB, 2-eFlow102NB, 3-ACMS8, 3-PDS8, RSB2, RSB1

T3MB755K1D

Trove3MBK3 with 1-eFlow104NB, 2-eFlow102NB, 3-ACMS8CB, 3-PDS8CB, RSB2, RSB1

24-Doors

1-LNL-2220 and 11-LNL-1320

Trove3MBK3 with 3-eFlow104NB, 3-ACMS8, 3-PDS8, RSB2, RSB1

T3MB777K1D

Trove3MBK3 with 3-eFlow104NB, 3-ACMS8, 3-PDS8, RSB2, RSB1

BR3M2PK

2-Pack of Angled Brackets for TROVE3MB3

Optional Accessories for TROVE3MBK3

Removeable Backplane For ease of deployment
Innovative Angle Brackets For Power distribution and Mercury hardware
Custom Wiring Options For power distribution and controller connections

TROVE3SWC

TROVE3BWC

718.567.8181 | info@altronix.com

13

Altronix® Altronix®

Outdoor Access and Power Integration

OnGuard Platform

Altronix Model

Description

System Capacity

Compatible Mercury* Models

Trove Outdoor Series - Weatherproof Enclosure for vehicle/pedestrian gate access

TROVE1M1WP

NEMA4/4X IP66 Outdoor Enclosure

2-Doors

LNL-2220, LNL-4420, LNL-1100, LNL-1200, LNL-3300, LNL-8000, LNL-2210, LNL-1300, LNL-1300e

Removeable Backplane For ease of deployment

Altronix Power Distribution Supporting the Mercury Hardware

Enclosure NEMA4-4X, IP66
14

718.567.8181 | info@altronix.com

Altronix® Rack Mount Access and Power Integration

OnGuard Platform

Front view *Boards not included
Cam Lock
Line Cord
718.567.8181 | info@altronix.com

Power LEDs
Rear view 2U Drawer on extendable rails for easy access
Z Bracket Included
15

Altronix®

Rack Mount Access and Power Integration

Altronix Model

Description

System Capacity

Mercury Trove1R 24" Rack Series - Accommodates Altronix Power and Distribution with Controllers

TROVE1M1R

2U Rack 19" Depth Enclosure + Backplane

4-Doors

Mercury Trove2R 40" Rack Series - Accommodates Altronix Power and Distribution with Controllers

TROVE2M2R

2U Rack 19" Depth Enclosure + Backplane

8-Doors

Altronix Model

Description

Altronix Model

Description

System Capacity

Trove 24" Rack Series Pre-assembled Kits

T1RM3F4

Fuse Protected Models

PTC Protected Models

eFlow6NB, ACM4, VR6, PDS8 T1RM3F4D

eFlow6NB, ACM4CB, VR6, PDS8CB

Trove 40" Rack Series Pre-assembled Kits

4-Doors

Fuse Protected Models

PTC Protected Models

T2RM7F8S eFlow104NB, ACMS8, VR6, PDS8 T2RM7F8SD eFlow104NB, ACMS8CB, VR6, PDS8CB

Managed Fuse Protected Models

Managed PTC Protected Models

T2RM7F8SQ eFlow104NB, LINQ8ACM, VR6, PDS8 T2RM7F8SDQ eFlow104NB, LINQ8ACMCB, VR6, PDS8CB 220VAC units available upon request, add suffix "V" (T1RM3F4V)

8-Doors

OnGuard Platform
Compatible Mercury* Models
LNL-2220, LNL-4420, LNL-1100, LNL-1200,
LNL-3300, LNL-8000, LNL-2210, LNL-1300, LNL-1300e
Compatible Mercury* Models
LNL-2220, LNL-4420, LNL-1100, LNL-1200,
LNL-3300, LNL-8000, LNL-2210, LNL-1300, LNL-1300e

T1RM3F4 4-Door Rack Access System with Power

Optional Accessory: - RE2 - Rack Mount Battery Enclosure (2U)
Accommodates up to four (4) 12VDC/7AH batteries

16

718.567.8181 | info@altronix.com

Altronix

OnGuard Platform

Pre-wired Rack Access and Power Integration Kits

Altronix Model

Description

Altronix Model

Description

System Compatible Capacity Mercury* Models

Trove1R 24" Series - Includes Power Distribution, Wire Assemblies for Controllers and Wire Magnets for Management

T1RM3CK1 T1RM7CK1

Fuse Protected Models

PTC Protected Models

Trove1M1R with eFlow6NB, ACM4, VR6, PDS8 T1RM3CK1D Trove1M1R with eFlow6NB, ACM4CB, VR6, PDS8CB

Trove1M1R with eFlow104NB, ACM4, VR6, PDS8 T1RM7CK1D Trove1M1R with eFlow104NB, ACM4CB, VR6, PDS8CB

4-Doors

1-LNL-2220 and 1-LNL-1320

Trove2R 40" Series - Includes Power Distribution, Wire Assemblies for Controllers and Wire Magnets for Management

Fuse Protected Models

PTC Protected Models

T2M7CK1 Trove2M2R with eFlow104NB, ACMS8, VR6, PDS8 T2M7CK1D Trove2M2R with eFlow104NB, ACMS8CB, VR6, PDS8CB

Managed Fuse Protected Models

Managed PTC Protected Models

T2M7CK1Q

Trove2M2R with eFlow104NB, LINQ8ACM, VR6, PDS8

T2M7CK1DQ

Trove2M2R with eFlow104NB, LINQ8ACMCB, VR6, PDS8CB

8-Doors

1-LNL-2220 and
3-LNL-1320

220VAC units available upon request, add suffix "V" (T1RM3CK1V)

T2RM7CK1DQ 8-Door Pre-Wired Rack Access System with Power

718.567.8181 | info@altronix.com

17

Power Supply/Chargers for TROVE Series

Altronix Model
AL400ULXB2 AL600ULXB AL1012ULXB AL1024ULXB2 AL400ULXB2V AL600ULXB220 AL1012ULXB220 AL1024ULXB2V
eFlow4NB eFlow6NB eFlow102NB eFlow104NB eFlow4NBV eFlow6NBV eFlow102NBV eFlow104NBV
Tango1B

Total Output Power

Number of Outputs

Built-in Battery Charger

ULXB Series Power Supply/Chargers

12VDC @ 4A or 24VDC @ 3A

12VDC or 24VDC @ 6A

12VDC @ 10A

24VDC @ 10A 12VDC @ 4A or 24VDC @ 3A

1

SLA

12VDC or 24VDC @ 6A

12VDC @ 10A

24VDC @ 10A

eFlow Series Power Supply/Chargers

12VDC or 24VDC @ 4A

12VDC or 24VDC @ 6A

12VDC @ 10A

24VDC @ 10A 12VDC or 24VDC @ 4A

1 Main Output, 1Aux. Output (1A)

SLA

12VDC or 24VDC @ 6A

12VDC @ 10A

24VDC @ 10A

Tango PoE Driven Power Supply/Charger

12VDC up to 6.25A (75W) and 24VDC up to 3A (75W)

2

LiFePO4

Input

Dimensions (L x W x H)

115VAC 220VAC

7.1" x 4.5" x 1.44" 7.1" x 4.5" x 2.6" 7.5" x 4.5" x 2.25" 8.4" x 4.5" x 1.95" 7.1" x 4.5" x 1.44" 7.1" x 4.5" x 2.6" 7.5" x 4.5" x 2.25" 8.4" x 4.5" x 1.95"

115VAC 220VC

7.5" x 4.6" x 1.75" 7.5" x 4.6" x 1.75" 7.5" x 4.6" x 1.75" 8.25" x 4.56" x 1.75" 7.5" x 4.6" x 1.75" 7.5" x 4.6" x 1.75" 7.5" x 4.6" x 1.75" 8.25" x 4.56" x 1.75"

90W 802.3bt PoE

7.625" x 4.125" x 1.25"

AL600ULXB

eFlow104NB

PoE Power Sourcing Equipment

Altronix Model NetWay1BT NetWay8BT

Description Single Port 802.3bt Converter/Injector - 115/230VAC Input, 90W Output 8-Port Managed 802.3bt Midspan Injector supplies 90W per port (480W total power)

NetWay1BT
18

NetWay8BT

718.567.8181 | info@altronix.com

Power Distribution / Sub Assemblies for TROVE Series

Altronix Model

Description

ACM4 / ACM4CB ACM8 / ACM8CB ACMS8 / ACMS8CB ACMS8K1 / ACMS8CBK1 ACMS12 / ACMS12CB
LINQ8PD / LINQ8PDCB
LINQ8ACM / LINQ8ACMCB
LPD M0M5 NETWAY5A NETWAY5B NETWAY5P NETWAY5PQ PD4UL / PD4ULCB PD8UL / PD8ULCB PDS8 / PDS8CB PDS8K1 / PDS8CBK1 PD16W / PD16WCB PDS16 / PDS16CB VR6 VR10

4-Output Access Power Controller 8-Output Access Power Controller Dual Input, 8-Output Access Power Controller Dual Input, 8-Output Access Power Controller and Voltage Regulator Kit Dual Input, 12-Output Access Power Controller Dual Input, 8-Output Network Power Distribution Module - Control, Monitor and report Power/Diagnostics Dual Input, 8-Output Network Power Access Power Controller - Control, Monitor and report Power/Diagnostics Low Power Disconnect Module (12/24VDC input) 5-Output Power Distribution Module with Fire Alarm Interface 5-Port Switch Board Facilitates Network Drops (10/100) 5-Port Switch Board Facilitates Network Drops (10/100/1000) 5-Port Hardened PoE+ Switch Board 5-Port Hardened Managed PoE+ Switch Board 4-Output Power Distribution Module 8-Output Power Distribution Module Dual Input, 8-Output Power Distribution Module Dual Input, 8-Output Power Distribution Module and Voltage Regulator Kit 16-Output Power Distribution Module Dual Input, 16-Output Power Distribution Module Stackable Voltage Regulator Converts a 24VDC input to 5VDC or 12VDC at 6A Stackable Voltage Regulator Converts a 24VDC input to 5VDC or 12VDC at 10A

Number of Outputs
4 8 8 8 12
8
8
N/A 5 5 5 5 5 4 8 8 8 16 16 1 1

Dimensions
5.175" x 3.36" x 1.25" 8" x 4.5" 1.25" 8" x 4.5" 1.25" 8" x 4.5" 2.125" 8" x 4.5" 1.25"
5.5" x 3.625" x 1.25"
8"x 4.5"x 1.25"
2" x 2.75" 1" 5.25" x 3.5" x 1" 5.625" x 3.5" x 1" 5.625" x 3.5" x 1" 5.6" x 3.6" x 0.75" 5.6" x 3.6" x 0.75" 5.21" x 3.25" x 1" 5.21" x 3.25" x 1" 5.375" x 3" x 1" 5.375" x 3" x 2" 5.875" x 6" x 0.95" 5.375" x 3" x 1" 5.375" x 3" x 1" 5.375" x 3" x 1"

Stackable sub-assemblies save valuable enclosure space, allowing for more power distribution and access controllers.

718.567.8181 | info@altronix.com

19

Optional Accessories for TROVE Series

Altronix Model

Description

BL3

18" Battery Leads (black and red)

BL4

8" Battery Series Jumper (yellow)

BL6

68" Battery Leads (black and red)

BR1

Add-on mounting bracket. Mount additional Altronix sub-assemblies to the enclosure's side wall.

BT126

12VDC / 7AH Rechargeable Battery

BT1212

12VDC / 12AH Rechargeable Battery

BTL125

Rechargeable 12V Lithium Iron Phosphate (LiFePO4) Battery

CLK1 DNP1 GB1

Thumb Lock. Fits Trove1, Trove2 and Trove3 enclosures.
Altronix DIN Rail Adapter Plate accommodates the following sub-assemblies: ACM4(CB, ACM8(CB), ACM8(CB), ACMS8(CB), ACMS12(CB), LINQ8PD(CB), LINQ8ACM(CB), MOM5, NETWAY5A, NETWAY5B, NETWAY5P, NETWAY5PQ,
PD4UL(CB), PD8UL(CB), PDS8(CB), PDS16(CB)
Altronix Adapter Plate for Genetec Synergis Cloud Link (For Mercury and HID/Vertx)

MM4

Mounting Magnets. 26 lbs. holding force. Pack of 4.

MM8

Mounting Magnets. 26 lbs. holding force. Pack of 8.

MM12

Mounting Magnets. 26 lbs. holding force. Pack of 12.

MM24

Mounting Magnets. 26 lbs. holding force. Pack of 24.

PSC1

Power Supply Protective Cover (Includes standoffs)

RSB1

Rocker Switch with Bracket - Includes single Master Power ON/OFF Switches and Wires

RSB2

Rocker Switches with Bracket - Includes two (2) Master Power ON/OFF Switches and Wires

SPACER1

5/8" Nylon female/female spacers (standoffs) with 6/32 screws. Pack of 25.

SPACER3

5/8" Aluminum female/female spacers (standoffs) with 6/32 screws. Pack of 25.

SPACER4

5/8" Nylon male/female spacers (standoffs) with 6/32 screws. Pack of 25.

SPACER5

5/8" Nylon snap-on spacers (standoffs) with 6/32 screws. Pack of 32.

SPACER6

1" Aluminum female/female spacers (standoffs) with 6/32 screws. Pack of 4.

SPACER7

5/8" Aluminum male/female spacers (standoffs) with 6/32 screws. Pack of 25.

SPACER8

1" Nylon female/female spacers (standoffs) with 6/32 screws. Pack of 4.

SPACER9

5/8" Aluminum spacers (standoffs) with 4/40 screws. Pack of 8.

TROVE2BWC

Wire trough/Battery enclosure compliments Trove2 enclosures to accommodate up to four (4) 12VDC/18AH batteries, or conceal side wiring (horizontal mount)

TROVE3BWC

Wire trough/Battery enclosure compliments Trove3 enclosures to accommodate up to four (4) 12VDC/18AH batteries, or conceal wiring (horizontal mount)

TROVE3SWC

Wire trough/Battery enclosure compliments Trove3 enclosures to accommodate up to four (4) 12VDC/40AH batteries, or conceal side wiring (vertical mount)

WM5

Magnetic cable tie mount. Accommodates standard zip ties. 16 lbs. holding force. Pack of 5.

WM10

Magnetic cable tie mount. Accommodates standard zip ties. 16 lbs. holding force. Pack of 10.

WM25

Magnetic cable tie mount. Accommodates standard zip ties. 16 lbs. holding force. Pack of 25.

WM100 Magnetic cable tie mount. Accommodates standard zip ties. 16 lbs. holding force. Pack of 100.

BTL125 CLK1
DNP1 PSC1
RSB2 TROVE3SWC
WM5

20

718.567.8181 | info@altronix.com

Rev. 0624

140 58th Street | Brooklyn, NY 11220 | 718.567.8181 | info@altronix.com

718.567.8181 | info@altronix.com

21



References

Adobe PDF Library 17.0 Adobe InDesign 19.5 (Macintosh)