V-TUF H6.500 / H6.501
V-TUF DUST DAMPER - INDUSTRIAL DUST SUPPRESSION CANNON
Daily (or Before Each Use)
- 1. Visual inspection of the nozzle and spray components: Check to see that all jets are spraying. If they are not, unscrew the jet and clear clogs, debris, algae, or buildup, then flush the system through and replace the clean jets. Nozzle blockages are common and should be addressed promptly.
- 2. Check pressure washer input: Verify inlet pressure (min. 15MPa) and flow (min. 15L/min).
- 3. Assess water quality: Use clean water to minimise sediment or buildup in tubing or nozzles.
- 4. Examine hoses and fittings: Inspect connections for leaks, wear, or damage - especially critical under high pressure.
- 5. Check adjustment mechanisms: Ensure the swivel base and pitch locks operate smoothly and securely without excessive play.
Weekly
- 1. Performance validation: Confirm spray pattern and mist projection remain consistent across intended range.
- 2. Check for wear or corrosion: Inspect base, fittings, and trolley (if present) - note any signs of corrosion or structural wear.
- 3. Functionality test under load: Operate under normal pressure for short duration - listen for leaks, irregular sound, or performance drop.
Monthly
- 1. Full system review: Evaluate overall performance and inspect gear, post-wear, or exposure.
- 2. Record inspection data: Log key metrics - inlet pressure/flow, nozzle condition, any adjustments made.
- 3. Assess stability & mounting: Ensure trolley brake (if present) and anchor points are secure and intact.
Semi-annually (6-Month Check)
- 1. Lubricate moving parts: Grease swivel joints and locking mechanisms as per general machinery maintenance recommendations.
- 2. Thorough cleaning: Flush lines and nozzles. Consider disassembling small components to remove buildup.
- 3. Detailed structural check: Inspect welds, bolts, framework for signs of fatigue or damage.
- 4. Compare performance data: Review logged values (pressure, flow, mist coverage) to detect any degradation over time.
Annually
- 1. Comprehensive safety audit: Review mechanical integrity of the trolley, base, pins, and locks. Check for loosened bolts or compromised welds.
- 2. Corrosion and deterioration check: Inspect surfaces exposed to water mist for rust or material degradation.
- 3. Filter and component replacement: Depending on usage, replace nozzle, hoses, or seals showing wear.
- 4. Update operator training & documentation: Ensure staff are trained on safe setup, operation, and maintenance - including winterisation or storage procedures.
Related Documents
![]() |
V-TUF AEROMAX500-240 Air Filtration Cleaner Turbo Fan - Technical Specifications Discover the V-TUF AEROMAX500-240, a powerful and portable air filtration cleaner and turbo fan designed for industrial and workshop environments. Featuring HEPA 14 filtration, low noise operation, and robust construction for cleaner air. |
![]() |
V-TUF ATX2000 45L M-Class Industrial Dust Extraction Vacuum Cleaner - ATEX Z22 Explore the V-TUF ATX2000, a compact 45-liter M-Class industrial dust extraction vacuum cleaner with ATEX Z22 rating. Features a powerful brushless motor, large polyester filter, and durable stainless steel container for efficient and safe operation. |
![]() |
V-TUF H6.500 Mist Blower Testing Results Comprehensive testing results for the V-TUF H6.500 mist blower, detailing performance metrics such as nozzle orifice, pressure, fan speed, spray range, and electric strut movement. |
![]() |
V-TUF ATX4500i Dust Extraction Vacuum Cleaner - ATEX Rated Z22 Discover the V-TUF ATX4500i, a powerful 45L M-Class dust extraction vacuum cleaner with ATEX Z22 rating. Features a brushless motor, semi-automatic filter cleaning, and robust construction for industrial environments. |
![]() |
V-TUF TORRENT 5 Industrial Mobile Diesel Cold Water Pressure Washer User Manual Comprehensive user and operator's manual for the V-TUF TORRENT 5 Industrial Mobile Diesel Cold Water Pressure Washer, covering safety, operation, technical data, troubleshooting, and maintenance. |
![]() |
V-TUF TORRENT 2 User Operators Manual This user manual provides comprehensive guidance for the V-TUF TORRENT 2 industrial mobile bowser cold water pressure washer, covering essential safety instructions, operational procedures, technical specifications, troubleshooting tips, and a list of accessories. It is designed for safe and effective use of the VTUF110B (110 volt) and VTUF240B (240 volt) models. |
![]() |
V-TUF ATX Series Industrial Vacuum Cleaner Operator Manual Comprehensive operator manual for V-TUF ATX Series industrial vacuum cleaners, including models ATX2000, ATX4500, and ATX4500i. Covers safety, operation, maintenance, and technical specifications for professional use. |
![]() |
V-TUF 240 MOD Operator Manual: Electric Industrial Pressure Washer Guide Comprehensive operator manual for the V-TUF 240 MOD electric industrial mobile stainless steel cold water pressure washer. Includes safety instructions, technical data, maintenance, troubleshooting, and accessories. |