User Manual for TBB Power models including: RSE-A, RSE-A Water Sensor, RSE-A, Water Sensor, Sensor

User manual of water sensor RSE-A

User manual - EN

Notice - evotechnologie.fr

[PDF] User manual of water sensor RSE-A - Photonic Universe evotechnologie.fr › wp-content › uploads › 2024/11 › RSE-A-Water-...

PDF preview unavailable. Download the PDF instead.

RSE-A-Water-sensor-User-manual A1.0 EN
User manual of water sensor RSE-A

User manual of water sensor RSE-A

Preface

User manual of water sensor RSE-A

Thanks for choosing our products and this manual is suitable for water sensor RSE-A. This manual contains important safety and operation instructions. Read it before any operation/installation and keep it well for future reference.
Product installation and maintenance need to be conducted by a well trained technician or electrician. Please pay more attention to below items:

1. Please use correct voltage to power this product

2. Please insure DC positive and negative are connected correctly. No reverse polarity connection is allowed

3. Please use power cable as short as possible for connection and ensure all connection is well

4. Only TBB engineer or authorized electrician can open the case.

All products has been well inspected before delivery from manufacturer. If there is faulty for example housing swelling is found when open product box, please contact TBB or TBB's re-seller immediately. The environment condition will also has influence to product performance, please make sure product is used in proper environment condition

Remarks: As continuous update on product, this manual might not reflect latest version of product. Please contact TBB or TBB's re-seller if wants to learn most update on product

User manual of water sensor RSE-A
Context
1. General Safety Instruction ........................................................................................................... 1 1.1 Safety instruction......................................................................................................... 1 1.2 General Precaution...................................................................................................... 1
2. Product introduction .................................................................................................................... 2 2.1 General introduction................................................................................................... 2 2.2 Features......................................................................................................................... 2 2.3 Product outlook ........................................................................................................... 2 2.4 Dip switch .................................................................................................................... 3
3. Installation...................................................................................................................................... 4

1. General Safety Instruction

User manual of water sensor RSE-A

1.1 Safety instruction
 Please read this manual and remark, sticker on product before installation or operation
 Please abide by required electrical safety procedure and requirement to prevent any damage or injury. Safety instruction in this manual is not equal to these safety procedure and requirement
 Manufacturer takes no responsibility for any consequence of break above safety procedure or requirement
 A warning mark as below represents potential risk or important information

Warning: The operation is critical to system running, please be careful before operation
1.2 General Precaution
 Do not expose product to dust, rain, snow or liquids of any typeit is designed for indoor use
 To avoid fire and electric shockmake sure all cables selected with right gauge and being connected well. Smaller diameter and broken cable are not allowed to use

1

2. Product introduction

User manual of water sensor RSE-A

2.1 General introduction
RSE-A is TBB's water sensor with capacitive technology. As part of functions of TBB's system solution, RSE-A has been widely used in recreational vehicle, marine, special vehicle etc. As a electronic type water sensor, RSE-A is able to provide precise water level measurement: every 5% as an interval. RSE-A is also with good performance on anti-interference so it's suitable for application of fresh/clean, grey and black water.
2.2 Features
1) With one I/O communication port for series connection 2) 12V power and working voltage is 9.6-16.0Vdc 3) Power consumption is less than 20mA 4) Working temperature: 085 5IP rating: IP65

2.3 Product outlook

Fig.2-1 Product outlook
2

2.4 Dip switch

User manual of water sensor RSE-A

There are three dip switches on product, which used for identification in the same system

Water tank No. Water tank No.1 Water tank No.2 Water tank No.3 Water tank No.4 Water tank No.5 Water tank No.6 Water tank No.7 Water tank No.8

Fig.2-2 Dip switch Table 2-1 Dip switch and its definition

Dip switch OFF OFF OFF000 OFF OFF ON001 OFF ON OFF010 OFF ON ON011 ON OFF OFF100 OFF ON ON101 ON ON OFF110 ON ON ON111

Definition Clean tank 1 Gray tank 1 Black tank 1 Clean tank 2 Gray tank 2 Black tank 2 Clean tank 3 Gray tank 3

3

3. Installation

User manual of water sensor RSE-A

1. Drill a hole at the cover of service open. The hole dimension can be referred to as below

Fig.3-1Dimension of RSE-A screw and nut (Unit:mm) 2. Pass RSE-A through that hole on service open from bottom to up

Fig.3-2 Pass RSE-A through the hole on servce open
3. Pass screw cap of RSE-A through cable and fix it with thread body 4

User manual of water sensor RSE-A
Fig.3-3 Pass screw cap of RSE-A through the cable 4. Well fix the screw cap with thread body by proper tool to prevent any leakage or loose
Fig.3-4 Fix screw cap with thread body 5. Also fix cover of service open back. The installation of RSE-A is finished
Fig.3-5 Fix back cover of service open
5

Remarks

User manual of water sensor RSE-A

1) Please keep installation of RSE-A away from water inlet with distance at least 10cm. Or it will cause measurement is not accurate
2) Please don't remove or damage tube plastic tube on probe, or it will cause malfunction of product
3) Please make sure dip switch at the top of product is in right position. The dip switch location has been applied glue for water proof
4) The probe length has been calibrated by manufacturer before delivery to customer. It's not allowed to cut probe length by user