Alphacool Eisstation 80 DC-LT Reservoir
Safety Instructions
⚠ Read the safety instructions before starting the installation.
- Not suitable for children under 6 years (contains small parts which could be swallowed).
- Do not run any cooling components without ensuring that cooling liquid is flowing through the cooling system. Coolers operated without coolant can become very hot. Caution: Burn Hazard!
- Coolers that have no coolant flowing through them can destroy the computer hardware. When switching on the hardware, always make sure that the pump is working.
- Please note when tightening the connectors or fittings, no tools such as screwdrivers, pliers, or wrenches should be used. All plastic products or metal threaded connections, which are linked with plastic parts, are easily over-loaded with tools. Cracking or other damages incurred in this way, as well as damage from leaking coolant, are not covered under the warranty!
- Use only connectors with a sealing o-ring. When using a sealing ring a firm tightening with the hand is enough. Your instruction manual will clearly refer to the use of tools in exceptional cases.
- If you have not done so yet, please check your hardware and cooling system (tightness, pump function and fans). This will minimize time spent searching for possible problems. ALPHACOOL INTERNATIONAL GMBH accepts no liability on the warranty of the manufacturer of the electronic components. The assembly of the cooling system takes place at your own risk.
- The screws should not be tightened too firmly. If you tighten the screws excessively, the knurled nuts can loosen and the cooler's uniform pressure is no longer guaranteed.
- Fasten the connections of your choice to the cooler. Do not use tools such as wrenches for fastening the connections. Connectors with 8mm long threads may stop the flow.
- We recommend a tightness test before assembling/installing the cooler. The water pressure in the water cooling loop can be at a maximum of 0.8 bar. DO NOT use tools on the connectors.
- Ensure that the cooler is touching all components to be cooled through thermal grease and thermal pads.
- Only use distilled water or ALPHACOOL CAPE KELVIN CATCHER in your cooling circuit. Damage caused by unsuitable coolant is not covered by the warranty!
Specified normal operation: All ALPHACOOL INTERNATIONAL GMBH cooling components are constructed and licensed for ALPHACOOL INTERNATIONAL GMBH computer construction parts. The warranty expires in case of misuse.
Warranty:
- Data, designs, illustrations, technical data, weight, measurement and specifications, contained in folders, catalogues, circulars, announcements or price lists, have a purely informative character. We do not undertake warranty for the correctness of these data. As to the kind and the range of delivery, the data contained in the order and confirmation of order alone are decisive.
- If there is a lack of warrantor, you are entitled, on the basis of the legal regulations to require subsequent delivery, to withdraw from the contract or reduce the purchase price. If you are a consumer, the limitation period of warranty claims for the supplied commodity amounts to two years starting from receipt of goods (§ 13 BGB). If you are an entrepreneur, in accordance with legal conditions the limitation period amounts to only one year (§ 14 BGB).
- The warranty claim is valid only in combination with the original invoice, the sales slip or an ALPHACOOL confirmation on warranty claim.
- It is ALPHACOOL INTERNATIONAL GMBH's own discretionary authority to replace or repair the defective product or defective component. The replaced product or component changes into property of ALPHACOOL INTERNATIONAL GMBH.
- All warranty claims are accomplished by ALPHACOOL INTERNATIONAL GMBH or its authorized dealers. If the repair is carried out by a non-authorized or assigned person, ALPHACOOL INTERNATIONAL GMBH does not take over either costs or liability, unless the repair has been previously agreed upon with ALPHACOOL INTERNATIONAL GMBH.
- All costs resulting from refitting of the products are not taken over by ALPHACOOL INTERNATIONAL GMBH.
- ALPHACOOL INTERNATIONAL GMBH's warranty excludes the following points: 7.1. Regular controls maintenance and repair or the replacement of parts subject to regular wear and tear. 7.2. Improper manipulation or defects caused by incorrect installation. 7.3. Damages caused by storm, water, fire, overvoltage, acts of God, war, incorrect connection to the net, insufficient or incorrect ventilation or other reasons over which ALPHACOOL INTERNATIONAL GMBH has no influence. 7.4. Damages resulting from transportation or improper packaging.
- Consumer’s rights are valid in the respective country; demands made to the salesman, as explained and laid down in the sales contract, will not be covered by this warranty. ALPHACOOL INTERNATIONAL GMBH, its Branch Office and Distributors, are not responsible for direct or indirect damage or losses, as far as the compelling legal regulations do not oppose it.
- ALPHACOOL INTERNATIONAL GMBH does not take over the warranty of the manufacturer of the electronic construction units and components. The assembly of the cooler takes place at your own risk.
Contact an authorized waste management company in your country. Disposal with municipal waste or similar collection facilities is not permissible.
Mounting Material
EISSTATION 80 DC-LT-Reservoir (Art. No. : 15371)
- 1x Reservoir
- 2x M3x8 screws
- 2x Stand supports
- 1x G1/4" plug
- 1x G1" plug
- 1x Plug key
- 1x Velcro mat
- 2x M3x5 screws
- 1x Hexagon key
- 4x M4 nuts
- 8x M4x6 screws
- 4x Decouplers (Vibration dampers)
Technical Details
Dimensions (in mm)
Without stand supports:
Diagrams show the reservoir's dimensions. Key measurements include height (77.00 mm, 51.30 mm, 39.80 mm), width (50.64 mm, 25.32 mm), and depth (25.70 mm, 25.00 mm). Inlet (IN) and outlet (OUT) ports are clearly marked.
With stand supports:
Diagrams show the reservoir with stand supports attached. The overall height with supports is approximately 92.50 mm or 112.50 mm.
Maximum water capacity: approx. 36 ml.
Pump compatibility: The Eisstation 80 DC-LT is compatible with all DC-LT pumps.
Installation
Installation of the Pump
First, remove the lower cover using M3x5 screws.
Screw the pump with an O-ring to the bottom of the reservoir using M3x8 screws.
Route the pump cable with the rubber kink protection through the opening in the pump casing.
Re-attach the lower cover using M3x5 screws.
Connecting Pump
The DC-LT pump is powered via a 3-pin connector. Plug the connector onto your motherboard's pump header.
Note: Some motherboards have dedicated pump sockets. If only fan sockets are available, ensure the total power does not exceed 10W.
Mounting in Case
The reservoir can be mounted in the case using a Velcro mat or stand supports.
1. Mounting with Velcro: Attach the upper Velcro mat to the reservoir cover and the lower Velcro mat to the case.
2. Mounting with stand supports and decouplers: There are two ways to mount the stand supports.
Attach the decouplers with nuts to the stand supports. Then mount the reservoir to the case using M4x6 screws.
Alphacool recommends using vibration dampers for case mounting.
Tubing and Commissioning
- Connect the tubes to the threaded inputs marked 'IN' (inlet) and 'OUT' (outlet).
- The pump casing inlet must be closed using the G1/4" plug and the plug key.
- Fill the reservoir with coolant using a funnel through the upper fillport.
Recommendation: Use clear coolants from Alphacool (CKC or Eiswasser Crystal - no UV) or pure distilled/osmosis-filtered water. After initial use, the water level may drop and require refilling.
Replace Reservoir
Alphacool also offers a transparent top for the "Eisstation 80 DC-LT" reservoir.
Scope of delivery for the transparent top (available separately): EISSTATION 80 DC-LT CLEAR TOP (Art. No. : 15374)
- 1x Reservoir (top)
- 1x G1" sealing plug
- 4x M4x40 screws
- 1x O-ring
- 1x Bubble down filter
To replace the top, unscrew the 4 M4x40 screws from the old top. Mount the transparent reservoir top using the same principle.
Imprint
Alphacool International GmbH
Marienberger Str. 1
38122 Braunschweig
Support: +49 (0) 531 28874 - 0
Fax: +49 (0) 531 28874 - 22
E-Mail: info@alphacool.com
General Manager: Fabian Noelte
WEEE-Reg.-Nr.: DE 544444
Trade Register: Amtsgericht Braunschweig HRB 202390
VAT.ID.Nr.: DE27058421
Tax number: 13/207/02047