Three-phase Residential On-grid Inverter
X3-PRO G2
8kW / 10kW / 12kW / 15kW / 17kW / 20kW / 25kW / 30kW
Product Image Description
Image of the Solax X3-PRO G2 inverter, a compact, white and grey unit with ventilation grilles and connection ports.
Key Features
High Efficiency
- ✔️ Up to 98.5% efficiency
- ✔️ 32A per MPP tracker
- ✔️ 150% DC oversizing & 110% AC overloading output
- ✔️ Built-in global MPP scan
- ✔️ Low startup voltage & ultra-wide MPPT range
Intelligent Design
- ✔️ IP66 protection degree
- ✔️ Ultra-high power density
- ✔️ 24h monitoring (WiFi/LAN/4G)
- ✔️ Smart loads management (e.g., heat pump, smart EV charger)
Assured Safety
- ✔️ Type II SPD on AC&DC side
- ✔️ AFCI support (optional) [Note: Feature to be upgraded in the future]
Flexible Adaptability
- ✔️ Built-in export power control function
Technical Specifications
Parameter | X3-PRO-8K-G2 | X3-PRO-10K-G2 | X3-PRO-12K-G2 | X3-PRO-15K-G2 | X3-PRO-17K-G2 | X3-PRO-20K-G2 | X3-PRO-25K-G2 | X3-PRO-30K-G2 |
---|---|---|---|---|---|---|---|---|
PV INPUT | ||||||||
Max. recommended PV array power | 12.0 kWp | 15.0 kWp | 18.0 kWp | 22.5 kWp | 25.5 kWp | 30.0 kWp | 37.5 kWp | 45.0 kWp |
Max. PV input voltage [Note ①] | 1100 V | |||||||
Nominal PV input voltage | 650 V | |||||||
Operating voltage range | 135 ~ 985 V | |||||||
MPPT voltage range [Note ②] | 160 ~ 980 V | |||||||
Start-up voltage | 200 V | |||||||
No. of MPP trackers / Strings per MPP tracker | 2 / (2 / 2) | 3 / (2 / 2 / 2) | ||||||
Max. input current per MPPT | 32 A | 40 A | ||||||
Max. input short circuit current per MPPT | 40 A | |||||||
AC OUTPUT | ||||||||
Rated output power | 8 kW | 10 kW | 12 kW | 15 kW | 17 kW | 20 kW | 25 kW | 30 kW |
Rated output current | 12.2 A | 15.2 A | 18.2 A | 22.8 A | 25.8 A | 30.3 A | 37.9 A | 45.5 A |
Max. output apparent power | 8.8 kVA | 11.0 kVA | 13.2 kVA | 16.5 kVA | 18.7 kVA | 22.0 kVA | 27.5 kVA | 30.0 kVA [Note ⑥] |
Max. output continuous current | 13.2 A | 16.0 A | 19.3 A | 24.2 A | 27.5 A | 33.6 A | 41.8 A | 45.5 A |
Nominal AC voltage | 3 / N / PE, 220 / 380 V | 3 / N / PE, 230 / 400 V | ||||||
Nominal AC frequency | 50 Hz / 60 Hz | |||||||
AC frequency range [Note ③] | 50 ± 5 Hz / 60 ± 5 Hz | |||||||
Adjustable Power Factor range | ~ 1 (0.8 lagging to 0.8 leading) | |||||||
THDi (rated power) | < 3% | |||||||
EFFICIENCY | ||||||||
Max. efficiency | 98.2% | 98.3% | 98.5% | 98.5% | 98.5% | 98.5% | 98.5% | 98.5% |
European efficiency | 97.7% | 97.8% | 98.0% | 98.0% | 98.0% | 98.0% | 98.0% | 98.0% |
ENVIRONMENT LIMIT | ||||||||
Ingress protection | IP66 | |||||||
Operating ambient temperature range | -30 ~ 60°C | |||||||
Max. operating altitude | 4000 m | |||||||
Relative humidity | 0 ~ 100 % RH (condensing) | |||||||
Overvoltage Category | Mains: III / PV: II | |||||||
Dimensions (W x H x D) | 482 x 417 x 186 mm | |||||||
GENERAL | ||||||||
Net weight | 24.5 kg | 26.0 kg | 28.0 kg | 28.0 kg | ||||
Cooling concept | Nature cooling | Smart cooling | ||||||
Communication interfaces | RS485/DRM, Optional: Meter | |||||||
Power consumption (night) | < 3 W | |||||||
Topology | Non-isolated | |||||||
Certificates and approvals | VDE4105, EN 50549, AS 4777.2, IEC 61727, IEC 62116, IEC 61683, IEC 60068, EN 50530, NB/T 32004, IEC/EN 62109-1, IEC/EN 62109-2 | |||||||
AC auxiliary power supply (APS) | Optional | |||||||
PROTECTION | ||||||||
Protections | Over / under voltage protection, DC isolation protection, DC reverse-polarity protection, Grid monitoring, DC injection monitoring, Back feed current monitoring, Residual current detection, Over temperature protection, AC overcurrent protection, AC short-circuit protection | |||||||
Active anti-islanding method | Frequency shift | |||||||
Surge protection (DC / AC) | DC: Type II, AC: Type II | |||||||
Arc-fault circuit interrupter (AFCI) | Optional |
[Note ①]: The maximum input voltage is the upper limit of the DC voltage. Any higher input DC voltage would probably damage the inverter.
[Note ②]: Input voltage exceeding the MPPT voltage range may trigger inverter protection.
[Note ③]: The AC frequency range may vary from different country codes.
[Note ④]: 9999 for AS4777.2
[Note ⑤]: 14999 for AS4777.2
[Note ⑥]: 29999 for AS4777.2