Technical Specifications

ParameterValue
OperatorShaft-50
Supply voltage, V/Hz220-240/50
Torque, N·m50
Motor rotational speed, rpm1 400
Shaft hole diameter (with key slot), mm25.4
Hand chain length, m8
Shaft rotational speed, rpm24
Door curtain maximum weight, kg270
Dimensions, mm406 x 259 x 115
Thermal protection, °C130
Intensity, %40
Power, W370
Protection classIP54
Operating temperature, °C-25...+50
Operator weight (with hand chain), kg24

Diagram: Operator Dimensions

The operator unit has overall dimensions of 406 mm in length, 259 mm in height, and 115 mm in width.

Cable Specifications

The document indicates cable requirements: 3*2.5 mm² (220-240V) compliant with FROR CEI 20-22 and CEI EN 50267-2-1, and also mentions 2*0.5 mm² and 4*0.5 mm² cables.

Mounting Options

Option 1

Description of mounting option 1, showing the operator unit positioned for attachment to a shaft and wall bracket.

Option 2

Description of mounting option 2, showing the operator unit positioned for attachment, possibly in a different orientation or configuration.

Installation

Step 1: Shaft Attachment

Illustration shows a collar being slid onto the drive shaft, preparing for the operator's connection.

Step 2: Securing the Operator to Shaft

The operator is shown being attached to the shaft, with a mechanism to secure it in place.

Step 3: Mounting Bracket Installation

Description of installing the mounting bracket assembly, showing screws and components being fastened.

Step 4: Connecting Operator to Bracket

The operator unit is depicted being attached to the previously installed mounting bracket.

Step 5: Hand Chain Attachment

An illustration shows a hand holding the operator unit while the hand chain is being connected or adjusted.

Step 6: Securing Operator Housing

Screws are shown being inserted into the operator's housing to secure its components.

Step 7: Final Securing of Components

More screws are depicted being inserted into the operator housing for final assembly and securing.

Step 8: Electrical Connections

Electrical wires are shown being connected to the terminals within the operator unit.

Step 9: Mounting Plate Assembly

A mounting plate is shown being assembled with screws and fasteners, ready for installation.

Step 10: Final Operator Attachment to Mount

The operator unit is shown being attached to the mounting assembly, with a tool indicating a tightening action.

Adjustment of Travel Limits

Steps 11 & 12: Initial Limit Switch Adjustment

Illustrations show the adjustment of mechanical limit switches using a tool, demonstrating two distinct positions for setting the limits.

Step 1: Limit Switch Cover Installation

Description of installing the protective cover over the limit switch mechanism.

Step 2: Limit Switch Mechanism Overview

A view of the internal components of the limit switch mechanism is shown.

Setting the Closed Position (Red Cam)

Step 1: Door in Closed Position

Illustration depicts the door in its fully closed state.

Step 2: Red Cam Adjustment

Description of adjusting the red cam on the operator's internal mechanism to define the fully closed limit for the door.

Setting the Opened Position (Green Cam)

Steps 3-6: Green Cam Adjustment for Opened Position

This section describes setting the opened position using the green cam. It involves rotating a component (Step 3), listening for an audible click ? (Step 4) to confirm the setting, and securing the cam (Step 5). Step 6 shows the door in the fully opened position.

Steps 1 & 2: Alternative View of Opened Position Setting

An alternative illustration showing the process of adjusting the green cam for the opened travel limit.

Fine Adjustment of Down Travel Limit

Steps 3-5: Fine Tuning the Closed Limit

This section details the fine adjustment for the down travel limit. It involves rotating a component (Step 3), listening for an audible click ? (Step 4), and making precise adjustments to the cam (Step 5).

Steps 1 & 2: Verifying Down Travel Limit

Illustration shows the door in the correct closed position (Step 1, marked with ✔️) and an incorrect closed position (Step 2, marked with ❌).

Fine Adjustment of Up Travel Limit

Steps 1 & 2: Initial Up Limit Adjustment

Description of the initial adjustment of the up travel limit using the operator's internal mechanism.

Steps 3 & 4: Fine Tuning the Opened Limit

Description of fine-tuning the up travel limit, showing adjustments being made to the cams.

Steps 3 & 4 (repeated): Alternative View of Up Limit Adjustment

An alternative illustration showing the process of fine-tuning the up travel limit.

Release Mechanism Operation

Steps 1-4: Operating the Release

This section explains how to operate the manual release mechanism. Step 1 shows pulling a lever or cord. Step 2 illustrates the door moving downwards manually. Step 3 provides another view of operating the release. Step 4 shows the door in the closed position, with a cross ❌ indicating an incorrect state after release, implying careful handling is required.

Chain Fixing

Steps 1 & 2: Preparing for Chain Fixing

Description of preparing to fix the chain. This involves hands holding the chain and a tool, such as a drill, being used.

Steps 3-5: Securing the Chain

This section details the process of fixing the chain to a mounting point. It includes attaching a plate, using screws, and securing the chain with a bolt and nut.

PDF preview unavailable. Download the PDF instead.

privod shaft 50 rus eng 2019 print Adobe PDF Library 15.0 Adobe InDesign 14.0 (Windows)

Related Documents

Preview DoorHan GSM-MODULE 3.0 User Manual and Technical Guide
Comprehensive user manual for the DoorHan GSM-MODULE 3.0, covering general information, connection diagrams, technical specifications, and programming via PC and SMS commands. Includes setup instructions and troubleshooting tips.
Preview DoorHan PCB-SL Control Board Programming and Electrical Connections Guide
Comprehensive guide to the DoorHan PCB-SL control board, covering electrical connections, DIP switch settings, transmitter programming, and mechanical regulator adjustments for gate automation systems.