Professional Transformer Compatibility List for LED Low Voltage Lamps
This document provides a recommended transformer compatibility list for Low Voltage LED lamps, specifically for non-dimmable systems. It is intended for informational purposes and is based on lab conditions, and results may vary.
Key
x-y: Transformer is compatible with x - y lamp.
N.A.: Transformer lamp combination not applicable/relevant.
T.B.D.: Transformer lamp combination not tested.
Red cell: Transformer is not compatible and therefore will not comply with claimed specifications.
Yellow cell: Transformer is compatible but will not work according to claimed specifications under all conditions.
Green cell: Transformer is compatible.
Transformer Compatibility Tables
The following tables detail the compatibility between various LED lamps and transformers. The tables are organized by LED lamp type and list compatibility ratings for different transformer models.
Brand / type | Watt | LED Watt | Transformer 50-150W | Transformer 50-250W | Transformer 20-105W | Transformer 10-70W |
---|---|---|---|---|---|---|
Philips Primaline 70 | 20-70 | 4-14 | 1 | 1 | 1 | 1 |
OSRAM Halotronic HTM 70 (new type) | 20-70 | 4-14 | 1 | 1 | 1 | 1 |
Philips ET-S60 | 20-60 | 4-12 | T.B.D. | N.A. | N.A. | T.B.D. |
Philips Certaline 60 | 20-60 | 4-12 | 1 | 1 | 1 | 1-2 |
SEET STE 70VA 7429 | 20-70 | 4-14 | 1 | 1 | 1 | 1 |
TCI PICO WOLF 60 | 10-60 | 4-12 | 1 | N.A. | 1 | 2 |
Vossloh Schwabe EST 60/12.635 | 10-60 | 4-12 | 1 | N.A. | 1 | 1 |
RELCO ICE60 PFS TH 60W | 10-60 | 4-12 | 1 | N.A. | 1 | N.A. |
Varilight YT50L | 0-50 | 0-10 | 1 | 1 | 1 | 1-2 |
Varilight YT70L | 0-70 | 0-14 | 1 | 1-2 | 1 | 1 |
Vossloh Schwabe EST 70/12.380 | 20-70 | 4-14 | 1 | 1 | 1 | 1 |
Paulmann Trafo Halo + LED 0-65W-97767 | 20-60 | 4-12 | 1-3 | 1-2 | 1-2 | 1-4 |
Govena YT60 | 20-70 | 4-14 | 1 | 1-2 | 1 | 1-2 |
SLV 461060 Micro 60 PFS | 20-60 | 4-12 | 1 | 1 | 1 | 1 |
Osram 111593 ET PARROT 70/220-240 | 10-60 | 4-12 | 1 | 1 | 1-2 | 1 |
TCI 119617 ROUND 70 | 20-70 | 4-14 | 1 | |||
EVN TAB 70 (3310) | 20-70 | 4-14 | 1 | 1 | ||
EVN MINIJOKER 70(T27/10) | 10-70 | 2-14 | N.A. | N.A. | N.A. | N.A. |
Niko 320-00121 | 10-65 | 0-40 | 1 | 1 | 1-2 | 1-2 |
Philips Primaline 105 | 35-105 | 7-20 | 1 | 1-2 | 1-3 | |
OSRAM Halotronic HTM 105 | 35-105 | 7-20 | 1 | 1-2 | 1-3 | |
Philips Certaline 105 | 35-105 | 7-20 | 1 | 1 | 1-2 | 1-3 |
RELCO ICE 105 PFS TH | 20-105 | 4-20 | 1-2 | 1 | 1-2 | 1-2 |
Vossloh Schwabe EST 105 | 20-105 | 4-20 | 1-2 | 1 | 1-2 | 1-2 |
Varilight YT105L | 0-105 | 0-20 | 1-2 | 1-2 | 1-2 | |
OSRAM ET-PARROT 105 | 35-105 | 7-20 | 1-2 | 1 | 1 | 1-3 |
Govena YT105 | 35-105 | 7-20 | 1-3 | 1-2 | 1-2 | 1-4 |
Osram 927019 HTL 105/230-240 | 35-105 | 7-20 | 1-2 | 1 | 1 | 2-3 |
TCI Pico Wolf 105 | 20-105 | 4-20 | 1-2 | 1 | 1 | 1-2 |
GIRA tronic trafo | 20-105 | 4-20 | 1-2 | 1 | 1 | 1-2 |
Osram HTI DALI 105/230_240 DIM+Dynalite DDBC120-DALI | 35-105 | 7-20 | 2-7 | 2-6 | 2-4 | N.A. |
Philips Primaline 150 | 50-150 | 10-30 | 1-2 | 1-2 | 1-3 | 1-2 |
OSRAM HTM 150 | 50-150 | 10-30 | 1-2 | 1-2 | 1 | |
Varilight YT150 | 0-150 | 0-30 | 1-3 | 1-2 | 1 | 1-3 |
SLV TRANSFORMATEUR, 12V AC, 150VA, | 50-150 | 10-30 | 1-2 | 1 | 1 | 1-4 |
TCI Wolf 150, WX 150 | 50-150 | 10-30 | 2 | 2 | 1 | 2-4 |
Jung SNT150 | 50-150 | 10-30 | 2 | 1-2 | 1 | 1-4 |
RELCO RN1684 FOX 150 PFS TH | 50-150 | 10-30 | 1 | 1 | 1 | 1 |
RELCO ICE 200 PFS TH | 100-200 | 20-40 | 2-4 | 2 | 1-2 | 2-4 |
Osram 927026 HTL 225/230-240 | 50-225 | 10-45 | 2-4 | 2-3 | 2 | 2-6 |
Dimmer Transformer Compatibility
The following section details the compatibility between LED lamps, transformers, and dimmers. The key indicates the compatibility level based on dimming range and number of lamps.
Brand | Model | Load | Transformer | Philips | Osram | Vossloh Schwabe | TCI | Govena | Varilight | Jung |
---|---|---|---|---|---|---|---|---|---|---|
MAS LED ExpertColor 7.5-43W MR16 | Legrand BTN4411N | 5-75VA | ET - S60 | 1 | 1 | 1 | 1-2 | 1 | 1 | 1-2 |
Legrand BTNT4411 | Primaline 70 | 1 | 1 | 1 | 1 | 1-2 | 1-2 | 1 | ||
Busch Jaeger | ABB BTL4411N | Certaline 105 | 1-2 | 1 | 1 | 1-2 | 1-2 | 1-2 | 1 | ||
MAS LEDspotLV D 7.5-50W MR16 | Busch Jaeger | ABB 6513 U-102 | [RC] 40-420W - Turn | HTM 70 | 1 | 1 | 1 | 1 | 1-2 | 1-2 | 1-2 |
Busch Jaeger | ABB 6523 UR-103 | [LED, R, L,C] 2-400W | EST 70 | 1 | 1-2 | 1 | 1 | 1 | 1 | 1 | |
Eltako EVD61NPN - UC | Trailing Edge - Turn - Leading 400W 3-wire Push | ROUND 70 | 1-2 | 1 | 1-2 | 1-2 | 1-2 | 1-2 | 1-2 | |
MAS LEDspotLV DimTone 5.8-35W MR16 36D | Merten | Schneider | Feller (MEG5134-0000) | Module [LED/RC] 4-200W(RC) 4-400W(RL) | YT 60 | 1 | 1-2 | 1-2 | 1-2 | 1-2 | 1 | 1-3 |
Merten | Schneider | Feller MEG5300-0001 (CCT99100) | [LED, RL, RC] 4 - 20VA RL LED/4-100VA | YT 105 | 1-2 | 1 | 1 | 1 | 1-2 | 1-2 | 1 | |
Philips UID8670 | RC LED [LED] 2-100VA - LED - Push (3wire) | YT 50L | 1 | 1-2 | 1-2 | 1-2 | 1 | 1 | 1-2 | |
MAS LED SPOT VLE D 5.8-35W MR16 | Schneider Feller SBD315RC (SBD 315, SDD 315, ATD315, CCT011533) | [RC] 315W | SNT 150 | 1-2 | 1 | 1 | 1-2 | 1-2 | 1 | 1-2 |
Varilight HQ3W | [R] 60-400W | 1 | 1-2 | 1 | 1 | 1 | 1-2 | 1 | ||
Vimar Universal dimmer 20135.1 | [LED] 3-200W - Tast | 1 | 1 | 1-2 | 1-2 | 1-2 | 1 | 1-2 |
Notes on Dimming Compatibility
- #1: Transformers and dimmers are tested with the number of LED light sources specified. Using a different number may result in suboptimal behavior. Some combinations may support more light sources than tested.
- #1a: Non-LED dedicated dimmers/transformers can typically be loaded up to 20% of their maximum power for LED sources.
- #1b: LED-dedicated dimmers/transformers can be loaded up to their specified maximum power.
- #2: Check LED light source packaging for compatibility with occupancy motion sensors.
- #3: Dimming range color indications: Green (min <30%, max ≥80%), Yellow (min 30%-50%, max ≥70%), Red (not compatible), Grey (not applicable), White (no data).
- #3a: Single point flicker within the dimming range is acceptable.
- #4: Some dimmer suppliers offer "active loads" (e.g., Busch Jaeger Compensator 6596) to improve dimming performance.
- #5: Performance may vary with different mains voltages as tests were conducted under nominal conditions.
- #6: Manufacturers may update dimmer/transformer designs, potentially affecting LED compatibility.
- #7: Philips/Signify dimmable LEDs are generally compatible with all dimmer types (R, RL, RC, RLC).
- #8: Mixing loads may lead to unexpected behavior or damage; Philips is not responsible for such issues.
- #9: LEDs are dimmable within the indicated range but may exhibit minor flickering at certain settings.
- #10: Information is believed accurate but provided "AS IS".
- #11: DALI ET test data is based on Dynalite DDBC120-DALI controller under limited conditions. Signify reserves the right to final interpretation.
©2025 Signify Holding. All rights reserved. Information is subject to change without notice. Signify is not liable for any action taken based on this information. Mentioned third-party products are indicative and not necessarily endorsed by Signify.