HT9020 AC+DC TRMS Power/Harmonic Clamp up to 1000A

1. ELECTRICAL SPECIFICATIONS

Accuracy is calculated as [% rdg + (number of dgt) x resolution]. It is referred to 23°C ± 5°C, <80%RH

DC VOLTAGE

Range Resolution Accuracy Input impedance Overload protection
0.1-999.9V 0.1V ±(1.0%rdg + 3dgt) 1MΩ 1000VDC/ACrms

AC (AC+DC) TRMS VOLTAGE

Range Resolution Accuracy Input impedance Overload protection
0.5-999.9V 0.1V ±(1.0%rdg + 3dgt) 1MΩ 1000VDC/ACrms

Max crest factor: 1.41, Fundamental: 50/60Hz ± 15%, Frequency bandwidth: 42.5Hz - 1725Hz

AC/DC VOLTAGE – MAX/MIN/CREST

Range Resolution Accuracy Response time Overload protection
0.5-999.9V 0.1V ±(3.5%rdg + 5dgt) 1s 1000VDC/ACrms

Input impedance: 1MΩ, Max crest factor: 1.41, Fundamental: 50/60Hz ± 15%, Frequency bandwidth: 42.5Hz - 1725Hz

DC CURRENT

Range Resolution Accuracy Overload protection
0.1-999.9A 0.1A ±(2.0%rdg + 5dgt) 1000ADC/ACrms

AC (AC+DC) TRMS CURRENT

Range Resolution Accuracy Overload protection
0.5-999.9A 0.1A ±(1.0%rdg + 5dgt) 1000ADC/ACrms

Max crest factor: 1.41, Fundamental: 50/60Hz ± 15%, Frequency bandwidth: 42.5Hz - 1725Hz

AC/DC CURRENT – MAX/MIN/CREST

Range Resolution Accuracy Response time Overload protection
0.5-999.9A 0.1A ±(3.5%rdg + 5dgt) 1s 1000ADC/ACrms

Max crest factor: 1.41, Fundamental: 50/60Hz ± 15%, Frequency bandwidth: 42.5Hz - 1725Hz

DYNAMIC INRUSH CURRENT DC, AC+DC TRMS

Range Resolution PEAK Accuracy Max RMS Accuracy Overload protection
1.0-99.9A 0.1A ±(2.0%rdg + 5dgt) ±(2.0%rdg + 5dgt) 1000ADC/ACrms
10-999A 1A

Crest factor: 3, Sample frequency: 4kHz, Response time: Peak: 1ms, Max RMS: calculated on: 16.7, 20, 50, 100, 150, 200ms

Accuracy declared for frequency: DC, 42... 69Hz

RESISTANCE AND CONTINUITY TEST

Range Resolution Accuracy Buzzer Overload protection
0.0Ω - 199.9Ω 0.1Ω ±(1.0%rdg + 5dgt) 12 < 150Ω 1000VDC/ACrms
1000ADC/ACrms
200Ω - 1999Ω
2.00kΩ-19.99kΩ 0.01kΩ
20.0kΩ - 29.9kΩ 0.1kΩ

FREQUENCY WITH TEST LEADS AND WITH JAWS

Range Resolution Accuracy Overload protection
42.5 - 69.0Hz 0.1Hz ±(1.0%rdg + 5dgt) 1000VDC/ACrms
1000ADC/ACrms

Voltage range for frequency measurement: 0.5 ÷ 1000V / Current range for frequency measurement with jaws : 0.5 ÷ 1000A

2. GENERAL SPECIFICATIONS

Mechanical characteristics:

Power supply:

Display:

Climatic conditions:

Reference guidelines:

This instrument satisfies the requirements of Low Voltage Directive 2014/35/EU (LVD) and of EMC Directive 2014/30/EU

This instrument satisfies the requirements of 2011/65/EU (RoHS) directive and 2012/19/EU (WEEE) directive

Phase Sequence and Phase Conformity

Voltage range Frequency range Overload protection
100 - 1000V 42.5 ÷ 69Hz 1000VDC/ACrms

Input impedance: 1MΩ

DC POWER

Range [kW] Resolution [kW] Accuracy
0.00 - 99.99 0.01 ±(3.0%rdg + 3dgt)
100.0 - 999.9 0.1

Input impedance: 1MΩ, Accuracy defined for voltage > 10V, current ≥ 2A

ACTIVE POWER, APPARENT POWER AC (AC+DC TRMS)

Range [kW, kVA] Resolution [kW, kVAR, kVA] Accuracy
0.00 - 99.99 0.01 ±(2.0%rdg + 3dgt)
100.0 - 999.9 0.1

Input impedance: 1MΩ, Accuracy defined for: sinusoidal waveform, 42.5..69Hz, Voltage ≥ 10V, Current ≥ 2A, Pf ≥ 0.5

REACTIVE POWER AC (AC+DC TRMS)

Range [kVAR] Resolution [kW, kVAR, kVA] Accuracy
0.00 - 99.99 0.01 ±(2.0%rdg + 3dgt)
100.0 - 999.9 0.1

Input impedance: 1MΩ, Accuracy defined for: sinusoidal waveform, 42.5..69Hz, Voltage ≥ 10V, Current ≥ 2A, Pf ≤ 0.9

ACTIVE ENERGY AC (AC+DC TRMS)

Range [kWh] Resolution [kWh] Accuracy
0.00 - 99.99 0.01 ±(2.0%rdg + 3dgt)
100.0 - 999.9 0.1

Input impedance: 1MΩ, Accuracy defined for: sinusoidal waveform, 42.5..69Hz, Voltage ≥ 10V, Current ≥ 2A, Pf ≥ 0.5

REACTIVE ENERGY AC (AC+DC TRMS)

Range [kVARh] Resolution [kVARh] Accuracy
0.00 - 99.99 0.01 ±(2.0%rdg + 3dgt)
100.0 - 999.9 0.1

Input impedance: 1MΩ, Accuracy defined for: sinusoidal waveform,42.5..69Hz, Voltage ≥ 10V, Current ≥ 2A, Pf ≤ 0.9

POWER FACTOR

Range Resolution Accuracy
0.20 ÷ 1.00 0.01 ±(2.0%rdg+2dgt)

Input impedance: 1MΩ, Accuracy defined for: sinusoidal waveform, 42.5..69Hz, Voltage ≥ 10V, Current ≥ 2A

VOLTAGE AND CURRENT HARMONICS

Harmonic order Fundam. Freq. [Hz] Resolution [V], [A] Accuracy (values not zeroed)
0 ±(5.0%rdg+20dgt)
1÷25 42.5 ÷ 69.0 0.1V/0.1A ±(5.0%rdg+10dgt)
THD% 0.1% ±(10.0%rdg+10dgt)

The accuracy of harmonics amplitude expressed in % is evaluated considering the accuracy of the parameters ratio

(*) Voltage harmonics are zeroed in the below conditions: • 1st harmonic: if value < 0.5V • DC, 2nd to 25th harmonics: if harmonic value <0.5% of fundamental value or if value < 0.5V Current harmonics are zeroed in the below conditions: • 1st harmonic: if value < 0.5A • DC, 2nd to 25th harmonics: if harmonic value <0.5% of fundamental value or if value < 0.5A

PDF preview unavailable. Download the PDF instead.

ht-instruments-ht9020-ds-en-vl Microsoft Word per Microsoft 365

Related Documents

Preview HT9023 DC/AC, AC+DC TRMS Power Clamp Meter Technical Specifications
Detailed technical specifications and features of the HT9023 DC/AC, AC+DC TRMS power clamp meter by HT Instruments. Covers electrical parameters, general specifications, performance metrics, and compliance information, along with EURO-INDEX services.
Preview HT3010 AC TRMS Clamp Meter up to 400A Specifications and Features
Detailed specifications for the HT3010 AC TRMS clamp meter, including electrical specifications for DC voltage, AC TRMS voltage, AC TRMS current, resistance, continuity, diode test, and frequency. Also covers general specifications, supply, display, climatic conditions, and reference guidelines.
Preview HT Instruments NEPTUNE Multifunction Professional Safety Multimeter Datasheet
Comprehensive datasheet for the HT Instruments NEPTUNE, a professional safety multimeter. Details electrical specifications, features, power supply, environmental conditions, and compliance information.
Preview HT Instruments MERCURY TRMS Thermal Multimeter Specifications and Features
Detailed specifications for the HT Instruments MERCURY TRMS Thermal Multimeter, covering electrical specifications, current measurements, resistance, capacitance, temperature, and general features. Includes information on accuracy, overload protection, and environmental conditions.
Preview HT Instruments MacrotestG3 Professional Installation Safety Tester Specifications
Detailed technical specifications for the HT Instruments MacrotestG3 professional installation safety tester, covering electrical specifications, RCD testing, earth leakage, voltage drop, and environmental parameters.
Preview HT Instruments HT9012 AC Clamp Meter User Manual
Comprehensive user manual for the HT Instruments HT9012 AC Clamp Meter, detailing safety precautions, operation, maintenance, and technical specifications. This guide provides instructions for accurate voltage, current, resistance, and continuity measurements.
Preview HT Instruments HT61-HT62 User Manual
Comprehensive user manual for the HT Instruments HT61-HT62 multimeter, detailing safety precautions, instrument description, operating instructions, maintenance, and technical specifications.
Preview HT Instruments T2000-T2100 User Manual
User manual for the HT Instruments T2000 and T2100 clamp meters, covering safety precautions, general description, operating instructions, maintenance, and technical specifications.