ORBIS® TUBE
Brand: LEDVANCE
Product Overview
The ORBIS® TUBE is a versatile linear LED lighting fixture designed for various applications. It offers adjustable color temperature (CCT) and dimming capabilities, providing flexible lighting solutions.
Technical Specifications
General Specifications
EAN | Wattage (W) | Light Source Output (Lumens) | Color Temperature (K) | Operating Temperature (°C) | Voltage (V~) | Current (mA) | Frequency (Hz) | Driver Factor (DF) | Beam Angle (°) | Lumen Output |
---|---|---|---|---|---|---|---|---|---|---|
4099854279317 | 9 | 1000 | 3000/-4000 | -20...+40 | 220-240 | 70 | 50/60 | >0.5 | 120 | 10000 |
4099854279331 | 9 | 820 | 3000/-4000 | -20...+40 | 220-240 | 70 | 50/60 | >0.5 | 120 | 10000 |
4099854279355 | 9 | 900 | 3000/-4000 | -20...+40 | 220-240 | 70 | 50/60 | >0.5 | 120 | 10000 |
4099854279379 | 9 | 900 | 3000/-4000 | -20...+40 | 220-240 | 70 | 50/60 | >0.5 | 120 | 10000 |
4099854279393 | 9 | 900 | 3000/-4000 | -20...+40 | 220-240 | 70 | 50/60 | >0.5 | 120 | 10000 |
4099854279416 | 9 | 820 | 3000/-4000 | -20...+40 | 220-240 | 70 | 50/60 | >0.5 | 120 | 10000 |
4099854279430 | 9 | 900 | 3000/-4000 | -20...+40 | 220-240 | 70 | 50/60 | >0.5 | 120 | 10000 |
4099854279454 | 12 | 1350 | 3000/-4000 | -20...+40 | 220-240 | 94 | 50/60 | >0.5 | 120 | 10000 |
4099854279478 | 12 | 1100 | 3000/-4000 | -20...+40 | 220-240 | 94 | 50/60 | >0.5 | 120 | 10000 |
4099854279492 | 12 | 1200 | 3000/-4000 | -20...+40 | 220-240 | 94 | 50/60 | >0.5 | 120 | 10000 |
4099854279515 | 12 | 1200 | 3000/-4000 | -20...+40 | 220-240 | 94 | 50/60 | >0.5 | 120 | 10000 |
4099854279539 | 12 | 1200 | 3000/-4000 | -20...+40 | 220-240 | 94 | 50/60 | >0.5 | 120 | 10000 |
4099854279553 | 12 | 1100 | 3000/-4000 | -20...+40 | 220-240 | 94 | 50/60 | >0.5 | 120 | 10000 |
4099854279577 | 12 | 1200 | 3000/-4000 | -20...+40 | 220-240 | 94 | 50/60 | >0.5 | 120 | 10000 |
Energy Efficiency and Product Details
Product Name | EAN | Quantity (n) | LED Type | Energy Rating |
---|---|---|---|---|
ORBIS TUBE 40CM CLICKCCTDIMIP44FRCH | 4099854279317 | 1 | AC60813 | E |
ORBIS TUBE 40CM CLICKCCTDIMIP44 FRBK | 4099854279331 | 1 | AC60813 | E |
ORBIS TUBE 40CM CLICKCCTDIMIP44 FRWT | 4099854279355 | 1 | AC60813 | E |
ORBIS TUBE 40CM CLICKCCTDIMIP44 FRWD | 4099854279379 | 1 | AC60813 | E |
ORBIS TUBE 40CM CLICKCCTDIMIP44 BUCH | 4099854279393 | 1 | AC60813 | E |
ORBIS TUBE 40CM CLICKCCTDIMIP44 BUBK | 4099854279416 | 1 | AC60813 | E |
ORBIS TUBE 40CM CLICKCCTDIMIP44 BUWT | 4099854279430 | 1 | AC60813 | E |
ORBIS TUBE 60CM CLICKCCTDIMIP44 FRCH | 4099854279454 | 1 | AC60814 | E |
ORBIS TUBE 60CM CLICKCCTDIMIP44 FRBK | 4099854279478 | 1 | AC60814 | E |
ORBIS TUBE 60CM CLICKCCTDIMIP44 FRWT | 4099854279492 | 1 | AC60814 | E |
ORBIS TUBE 60CM CLICKCCTDIMIP44 FRWD | 4099854279515 | 1 | AC60814 | E |
ORBIS TUBE 60CM CLICKCCTDIMIP44 BUCH | 4099854279539 | 1 | AC60814 | E |
ORBIS TUBE 60CM CLICKCCTDIMIP44 BUBK | 4099854279553 | 1 | AC60814 | E |
ORBIS TUBE 60CM CLICKCCTDIMIP44 BUWT | 4099854279577 | 1 | AC60814 | E |
This product contains a light source of energy efficiency class E.
Dimensions
Product | L (mm) | W (mm) | H (mm) |
---|---|---|---|
ORBIS TUBE 40CM | 400 | 70 | 54 |
ORBIS TUBE 60CM | 600 | 70 | 54 |
Installation Guide
Step 1: Power Off and Preparation
Ensure the power supply is switched OFF before commencing installation. The diagram shows a hand operating a switch, moving it from the 'OFF' position to the 'ON' position, indicating the need to turn power off first. ⚠️Warning: Always disconnect power before installation.
Step 2: Mounting Bracket Installation
The diagram illustrates attaching mounting brackets to the wall or ceiling. This involves using screws [screw] and wall plugs [wall plug] for secure fixation. The diagram shows two brackets being positioned and fixed.
Step 3: Attaching the Fixture
This step shows how to attach the ORBIS® TUBE fixture to the previously installed mounting brackets. It involves aligning the fixture and securing it. A diagram shows drilling holes for wall plugs, with a specified diameter of ø6mm.
Step 4: Electrical Connection
Detailed instructions for connecting the power cable. The diagram shows a terminal block with three connection points labeled L (Line), N (Neutral), and PE (Protective Earth). Correct connection is indicated by a checkmark ✅, and incorrect by a cross ❌. Ensure wires are stripped to the correct length: 35mm for the housing and 10mm for the terminal connection. Use wires with a cross-section of 0.75-1.5mm².
Step 5: Securing the Luminaire
The diagram shows using a screwdriver [screwdriver] to secure the luminaire, likely by tightening screws that hold the fixture in place or close the housing.
Step 6: Power On Check
Similar to Step 1, this step shows the power switch being turned ON. This is a confirmation step after all connections are made.
Step 7: CCT and Dimming Control
The ORBIS® TUBE features integrated control for Color Temperature (CCT) and Dimming.
- 1x Touch: Changes the CCT between 3000K and 4000K.
- >3s Touch: Activates dimming, adjusting brightness from 100% down to 10%.
Step 8: Final Mounting and Orientation
The final step shows the fixture being mounted. It is crucial that the drain hole of the product must be oriented downward ⬇️ when installing. This ensures proper drainage and prevents moisture buildup.
Compliance and Disposal
Certifications: The product complies with CE and EAC standards.
IP Rating: The fixture has an IP44 rating, meaning it is protected against solid objects greater than 1mm and splashing water from any direction.
Disposal: Please dispose of this product and its accessories responsibly. [Recycling symbol - Dispose of in store] or [Recycling symbol - Dispose of in landfill].