Fogair+
Cordless nebulising kit for the effective disinfection of surfaces.
Introduction
Dear Customer,
Thank you for placing your trust in a quality product from TEINNOVA. This product has been made using modern manufacturing techniques and thorough quality assurance measures. TEINNOVA strives to ensure customer satisfaction and ease of operation. For any questions regarding this product, please contact your stockist or TEINNOVA directly. Before use, carefully read the operating instructions for your equipment. Treat this manual as part of the product and keep it accessible for future reference.
Training Service
TEINNOVA offers optional training specific to its products, teaching operators how to provide the best service and contribute to customer success. This includes guidance on preparing fair quotes, responding to specific problems, and offering professional and efficient service.
Technical Service
As TEINNOVA manufactures its own cleaning equipment, it maintains strict control over product quality and performance. This allows for low-cost service rates, provided by TEINNOVA's Technical Support Service, managed by the same team as the factory. TEINNOVA offers a full range of spare parts and related accessories for its equipment.
Symbols Used
This section explains all symbols used in this manual and on the equipment. It is crucial to read the associated text carefully, as it pertains to personal and equipment safety.
- DANGER! ❗ This symbol warns of a potentially dangerous situation that could result in serious injury or death if instructions are not followed. Refer to the “Safety Information” section.
- WARNING! ⚠️ This symbol warns of a potentially dangerous situation that could result in minor or moderate injury, or property damage leading to injury, if instructions are not followed.
- ATTENTION! ? This symbol indicates a situation that may cause property damage without causing injury, if instructions are not followed.
- IMPORTANT! ℹ️ This symbol highlights information for optimal equipment use and avoiding improper operation.
Know Your Equipment
Description and Content
The ULV (ultra-low volume) electric nebuliser generates large volumes of air at low pressure. It produces a cold fog of small particles (10-80 microns) that disperse in the air and land on all surfaces without staining. It uses minimal product for disinfecting bacteria, fungi, and viruses. The device is cordless, powered by a long-lasting lithium battery, allowing the operator to move freely without being tethered to a power source.
Applications
- Disinfection of spaces: ?
- Disinfection of air ducts: ?
- Vehicles of all kinds: ?
Key features include a Rechargeable Li-ion Battery ?, an 8-litre Product Tank ?️, and Silent ? operation.
Equipment Parts and Contents
The Fogair+ unit comprises several key components:
- Product Tank: Holds the disinfectant solution.
- Carrying Handle: For easy transport.
- On/off button: To control the device's operation.
- Flexible Hose: Connects the unit to the outlet nozzle.
- Battery Box Cover: Protects the battery compartment.
- Battery Housing Box: Contains the battery.
- Motor: Powers the nebulisation process.
- Battery Charger: For recharging the battery.
- Tank Cap: Seals the product tank.
- Straps for carrying it as a backpack: For comfortable transport.
- Motor Filter: Filters air entering the motor.
- Outlet Nozzle: Disperses the mist.
Interchangeable Nozzles
A flat-head screwdriver is required to change the misting nozzles. The available nozzles offer different droplet sizes and flow rates:
OUTLET | DROPLET | FLOW RATE |
0,5 mm | 10 micras | 30ml/min |
1,0 mm | 40 micras | 125ml/min |
1,5 mm | 80 micras | 300ml/min |
These nozzles come as standard with the equipment.
Use of the Equipment's Battery
To check the battery charge level, press the red TEST button on the control panel. A red light indicates the battery needs full recharging. The equipment offers an autonomy of 100 to 120 minutes after a full battery charge.
Battery Status Indicator:
- Discharged
- 25%
- 50%
- 75%
- 100%
Level check button
Charging the Battery
- Disconnect the battery from the equipment by unplugging the connector.
- Remove the battery from the housing by pulling the top handle until it is outside the box.
- Connect the battery to the charger and wait until it is 100% charged.
- Place the battery back into the equipment box with the TEST panel facing outwards, and connect the battery cable to the equipment cable.
Safety Warnings
General Safety:
- FOGAIR+ must only be used for purposes described in this manual.
- Users must be properly trained and use appropriate protective equipment.
- Store the equipment properly for transport.
- Regularly check the equipment for breakages and its condition.
- In case of a fault, contact TEINNOVA Technical Assistance Service at +34 941 44 50 56.
Personal Protective Equipment (PPE)
The following PPE is recommended when using the Fogair+:
- Watertight safety goggles for eye protection.
- Self-filtering mask for activated carbon gases.
- Type 4 chemical protection suit.
- Butyl gloves.
- Chemical protection safety footwear.
Operating Instructions
Before use:
Calibrate the flow regulator located at the end of the hose. Turn the flow regulator until it is completely closed. Once closed, push the base of the regulator downwards and align it with the groove of the air output.
Operation:
- Never overfill the 8-litre/2.1-gallon tank capacity.
- Mix chemicals in a separate container before adding them to the tank.
During use:
- Do not place the FOGAIR directly on the floor to avoid contact with dust and dampness.
- When working in a confined area, do not leave the FOGAIR running for more than 30 minutes.
- The amount of liquid misted depends on the type of nozzle fitted.
Troubleshooting Guide
Problem ❌ | Solution ✔️ |
Low fog potency. | Ensure the lid of the tank is tightly closed. |
Liquid forms around the motor casing and the bolts. | The equipment has been running for too long, causing droplets to form around the screws. |
The nebuliser behaves erratically, turning itself on and off. | Check the battery is sufficiently charged. The motor could be damaged or worn. |
The nebuliser heats up during normal usage. | Clean the filters at the bottom of the equipment. |
Technical Specifications
TECHNICAL FEATURES | |
Nominal voltage | 24V- 30Ah |
Motor power | 260 W |
Coverage | 5 to 7 metres |
Droplet size | Adjustable from 10 to 80 microns |
Injected flow rate | 30 a 300 ml/min |
Tank capacity | 8 litres / 2.1 gallons |
Hose length | 100 cm / 39.3 inch |
Sound level | 60 dB |
Dimensions (L x W x H) | 980 x 150 x 250 mm (38.5 x 5.9 x 9.8 inch) |
Empty weight | 5.2 kg / 12 lb |
Maintenance and Care
- Inspect the venturi tube of your FOGAIR+ after use for wear or damage. If signs of wear or damage are present, the droplet size may be incorrect and the tube will need replacement.
- Regularly examine all soft parts, such as hoses and gaskets, for wear. Replace any parts that are broken or damaged.
- Like any device for applying chemical products, it is essential to clean all equipment parts to prevent residue build-up that could affect performance.
- Regularly clean the filters located in the motor's lower cover.
Spare Parts:
TEINNOVA offers spare parts for all equipment. For any part or consumable needs, please contact TEINNOVA Customer Service at +34 941 44 50 56.
Waste Management
Materials used in packaging are recyclable. Do not dispose of packaging in household waste; hand it in at official recycling collection points.
Do not dispose of electrical equipment in the trash! ♻️
TEINNOVA recommends that electrical tools and accessories undergo an environmentally friendly recovery process. Please dispose of materials in the appropriate container or at your local collection point.
This complies with Directive 2012/19/EU of 4 July 2012 on waste electrical and electronic equipment (WEEE). ⚡
Accessories and Consumables
Consumables
- AK-GERMA 100: Super concentrated disinfectant for germs, fungi, and viruses. Available in a 1-litre pack. CODE: PQ8400113
- BATTERY SPARE RECHARGEABLE LI-ION. CODE: AC3304700
Guarantee Conditions
1. Warranty Period: TEINNOVA guarantees its products for 15 days against aesthetic defects or faults noticeable at first sight, and for 1 year against other manufacturing defects. The Buyer must report any defect as soon as it is discovered, within a maximum of 5 days from its appearance. Failure to do so may void the guarantee.
TEINNOVA will arrange for product collection and delivery to the factory or nearest official Technical Support Service for inspection. The applicability of the guarantee will be determined at this point. If the guarantee applies, TEINNOVA covers transport fees for collection and return. If the guarantee is excluded (Section 2), the Buyer covers transport fees.
TEINNOVA reserves the right to dismiss a guarantee claim if non-conformity is not evident and coverage is not expressly approved. If covered, TEINNOVA will replace the product or determine the necessary repair method.
All repair work under guarantee must be performed at TEINNOVA facilities or designated locations. The guarantee covers materials and labour for repairs or replacements of defective parts. The maximum guaranteed value is the product's sale price to the Buyer. Claims under guarantee do not permit withholding payment of invoices.
2. Guarantee Exclusions: The guarantee does not cover: unauthorized alterations or manipulations; indirect or consequential damage; damage from negligence, improper use, or non-compliance with instructions; intentional damage; faults from product adaptations or use of uncertified parts; fault detection costs; collection or replacement costs (unless non-conformity is proven within the limits of Section 1).
Declaration of Conformity “CE”
MODEL: FOGAIR +
SERIAL NUMBER: SD31402070000 - SD31402079999
MANUFACTURER INFORMATION:
Manufacturer name: TECAI INNOVA S.L.
Telephone number: +34 941 44 50 56
Fax: +34 941 25 24 71
Web: www.teinnova.net
TECAI INNOVA, SL, under its sole responsibility, certifies that the machine model described above complies with the essential requirements of the following directives:
- Machinery directive 2006/42/CE
- Directive 2014/30/EU on electromagnetic compatibility and its amendments.
- Directive 2014/35/EU on the sale of electrical equipment.
RESPONSIBLE FOR THE TECHNICAL DOSSIER:
Technical Director
ARMANDO SÁENZ ANGULO
Pol. Ind. Cantabria, C/Las Balsas 16
26009 Logroño (La Rioja)
SIGNATURE: ARMANDO SÁENZ ANGULO
Technical Director
Made in Logroño, 9 August 2020