MEAN WELL SPAN02 & DPAN02 Series 2W SIP Package DC-DC Regulated Converters
Product Overview and Technical Specifications
Product Description
The SPAN02 and DPAN02 series are 2W isolated and regulated module type DC-DC converters featuring a SIP8 package with industry-standard pinout. They offer a 2:1 wide input range, high efficiency up to 85%, and operate across a wide temperature range of -40°C to +90°C. Key features include 1.5KVDC I/O isolation, compliance with BS EN/EN55032 radiated Class A without additional components, overload protection, and continuous-mode short circuit protection. These converters are suitable for various systems such as industrial control, telecommunication fields, and distributed power architectures.
Key Features
- SIP8 package with industry standard pinout
- 2:1 wide input range
- Operating temperature range: -40°C to +90°C
- No minimum load required
- Comply to BS EN/EN55032 radiated Class A without additional components
- High efficiency up to 85%
- Protections: Short circuit (Continuous) / Overload
- 1.5KVDC I/O isolation
- Remote ON/OFF control
- 3 years warranty
Applications
- Telecom/datacom systems
- Wireless networks
- Industrial control facilities
- Instruments
- Analyzers
- Detectors
- Data switches
Model Encoding
The model encoding follows a structure to define input voltage, output voltage, and series type:
Example: SPAN02E-12
- Series name: SPAN02 (Single output) or DPAN02 (Dual output)
- Input voltage: E: 4.5~9Vdc, A: 9~18Vdc, B: 18~36Vdc, C: 36~75Vdc
- Output voltage: Single: 3.3/5/12/15Vdc; Dual: ±5/±12/±15Vdc
- Rated wattage: 2W
Model Selection Table
ORDER NO. | INPUT VOLTAGE (RANGE) | INPUT CURRENT | OUTPUT VOLTAGE | OUTPUT CURRENT | EFFICIENCY (TYP.) | CAPACITOR LOAD (MAX.) | |
---|---|---|---|---|---|---|---|
NO LOAD | FULL LOAD | ||||||
SPAN02E-03 | 5V (4.5~9V) | 60mA | 452mA | 3.3V | 0~500mA | 74% | 500μF |
SPAN02E-05 | 60mA | 526mA | 5V | 0~400mA | 78% | 400μF | |
SPAN02E-12 | 60mA | 501mA | 12V | 0~167mA | 80% | 167μF | |
SPAN02E-15 | 65mA | 503mA | 15V | 0~134mA | 80% | 134μF | |
DPAN02E-05 | 60mA | 519mA | ±5V | ±0~200mA | 78% | *200μF | |
DPAN02E-12 | 60mA | 504mA | ±12V | ±0~83mA | 80% | *83μF | |
DPAN02E-15 | 60mA | 503mA | ±15V | ±0~67mA | 80% | *67μF | |
SPAN02A-03 | 12V (9~18V) | 30mA | 181mA | 3.3V | 0~500mA | 76% | 500μF |
SPAN02A-05 | 32mA | 211mA | 5V | 0~400mA | 80% | 400μF | |
SPAN02A-12 | 32mA | 204mA | 12V | 0~167mA | 83% | 167μF | |
SPAN02A-15 | 32mA | 202mA | 15V | 0~134mA | 84% | 134μF | |
DPAN02A-05 | 31mA | 211mA | ±5V | ±0~200mA | 79% | *200μF | |
DPAN02A-12 | 31mA | 202mA | ±12V | ±0~83mA | 82% | *83μF | |
DPAN02A-15 | 31mA | 202mA | ±15V | ±0~67mA | 83% | *67μF | |
SPAN02B-03 | 24V (18~36V) | 18mA | 90mA | 3.3V | 0~500mA | 76% | 500μF |
SPAN02B-05 | 19mA | 105mA | 5V | 0~400mA | 79% | 400μF | |
SPAN02B-12 | 19mA | 102mA | 12V | 0~167mA | 82% | 167μF | |
SPAN02B-15 | 19mA | 101mA | 15V | 0~134mA | 83% | 134μF | |
DPAN02B-05 | 18mA | 105mA | ±5V | ±0~200mA | 79% | *200μF | |
DPAN02B-12 | 19mA | 102mA | ±12V | ±0~83mA | 81% | *83μF | |
DPAN02B-15 | 19mA | 100mA | ±15V | ±0~67mA | 85% | *67μF | |
SPAN02C-03 | 48V (36~75V) | 9mA | 46mA | 3.3V | 0~500mA | 75% | 500μF |
SPAN02C-05 | 9mA | 53mA | 5V | 0~400mA | 80% | 400μF | |
SPAN02C-12 | 9mA | 51mA | 12V | 0~167mA | 82% | 167μF | |
SPAN02C-15 | 9mA | 50mA | 15V | 0~134mA | 83% | 134μF | |
DPAN02C-05 | 12mA | 53mA | ±5V | ±0~200mA | 78% | *200μF | |
DPAN02C-12 | 12mA | 51mA | ±12V | ±0~83mA | 82% | *83μF | |
DPAN02C-15 | 9mA | 50mA | ±15V | ±0~67mA | 84% | *67μF |
Specifications
Input:
- Voltage Range: E: 4.5~9Vdc, A: 9~18Vdc, B: 18~36Vdc, C: 36~75Vdc
- Surge Voltage (100ms max.): 5Vin: 15Vdc; 12Vin: 25Vdc; 24Vin: 50Vdc; 48Vin: 100Vdc
- Filter: Internal capacitor; Fuse recommended (e.g., 5Vin: 1000mA Slow-Blow Type)
- Internal Power Dissipation: 500mW
Output:
- Voltage Accuracy: ±1.5%
- Rated Power: 2W
- Ripple & Noise: 75mVp-p
- Line Regulation: ±0.5%
- Load Regulation: Single output models: ±0.5%; Dual output models: ±1%
- Switching Frequency (Typ.): 100KHz
Protection:
- Short Circuit: Continuous, automatic recovery
- Overload: Recovers automatically after fault condition is removed
- Under Voltage Lockout: Start-up voltage (e.g., 5Vin: 4.2Vdc), Shutdown voltage (e.g., 5Vin: 3Vdc)
- Remote Control: Power ON: R.C. ~ -Vin <0.8Vdc or open circuit; Power OFF: R.C. ~ -Vin >4 ~ 15Vdc
Environment:
- Cooling: Free-air convection
- Working Temp.: -40°C to +90°C (Refer to Derating Curve)
- Case Temp.: +100°C max.
- Working Humidity: 20% ~ 90% RH non-condensing
- Storage Temp., Humidity: -55~+125℃, 10~95% RH non-condensing
- Temp. Coefficient: 0.03% / °C (0~85°C)
- Soldering Temp.: 1.5mm from case, 1~3sec./260°C max.
- Vibration: 10~500Hz, 2G, 10min/cycle, 60min per axis
Safety & EMC:
- Safety Standards: EAC TP TC 020/2011 (EAC TP TC 004 for 48Vin type only) approved
- Withstand Voltage: I/P-O/P: 1.5KVDC
- Isolation Resistance: I/P-O/P: 100M Ohms / 500VDC / 25°C/70% RH
- Isolation Capacitance: 10pF (Typ.)
- EMC Emission: Conducted: BS EN/EN55032(CISPR32); Radiated: BS EN/EN55032(CISPR32) Class A
- EMC Immunity: ESD (Level 2), Radiated Susceptibility (Level 2), EFT/Burest (Level 1), Surge (Level 1), Conducted (Level 2), Magnetic Field (Level 2)
Others:
- MTBF: 2500Khrs (MIL-HDBK-217F, 25°C)
- Dimension (L*W*H): 21.8*9.2*11.1mm (0.86*0.36*0.44 inch)
- Case Material: Non-Conductive black plastic (UL 94-0 rated)
- Packing: 2.7g per unit; 14pcs/tube, 2058pcs/carton
Mechanical Specification
Dimensions: The converters measure 21.8mm (0.86 inch) in length, 9.2mm (0.36 inch) in width, and 11.1mm (0.44 inch) in height. Tolerances are ±0.5mm for general dimensions and ±0.05mm for pin pitch.
Pin Assignment
Pin No. | SPAN02 (Single output) | DPAN02 (Dual output) |
---|---|---|
1 | -Vin | -Vin |
2 | +Vin | +Vin |
3 | R.C. | R.C. |
5 | N.C. | N.C. |
6 | +Vout | +Vout |
7 | -Vout | Common |
8 | N.C. | -Vout |
Derating Curve
The derating curve illustrates the load capacity versus ambient temperature under natural convection. The converters can operate at full load up to approximately 60°C. Beyond this temperature, the maximum allowable load decreases linearly, reaching 0% at 90°C ambient temperature.
Packing Information
Products are typically packed in standard tubes. Each tube contains 14 pieces with a gross weight of 56.3g. A carton can hold up to 2058 pieces, with a total carton gross weight of 10.28Kg. Carton dimensions are approximately L390.9 x W284.8 x H175.7 mm.
Installation Manual
For detailed installation instructions, please refer to the MEAN WELL website: