Model 8500

Instructions for Use

CE 0123

Instructions for Use / Operator's Manual

NONIN

Rx Only

https://www.nonin.com/support/8500

ENG – Translations of the IFU can be found using this QR code.

FRE – Les traductions de cette notice d'utilisation peuvent être retrouvées à l'aide de ce code QR.

GER – Übersetzungen dieses Handbuchs können über diesen QR-Code abgerufen werden.

ITL – Utilizzando questo codice QR, è possibile trovare le traduzioni delle Istruzioni per l'uso.

SPA – Las traducciones de este manual se pueden encontrar utilizando este código QR.

POR – Pode aceder às traduções das instruções de utilização através deste código QR.

DUT – Vertalingen van de handleiding zijn te vinden met behulp van deze QR-code.

GRK – Με τη χρήση αυτού του κωδικού QR μπορείτε να βρείτε μεταφράσεις των οδηγιών χρήσης (IFU).

DAN – Scan denne QR-kode for at finde oversættelser af denne brugsvejledning.

SWE – Översättningar av den här guiden kan hittas med denna QR-kod.

FIN – Käyttöohjeen käännökset löytyvät tällä QR-koodilla.

POL – Tłumaczenia tego przewodnika można znaleźć za pomocą tego kodu QR.

NOR – Oversettelser av denne bruksanvisningen kan finnes ved å bruke denne QR-koden.

Warranty

The device warranty is 3 years.

nonin.com/warranty

Symbol Glossary

nonin.com/symbols

Compliance

This product complies with ISO 10993.

Not made from natural rubber latex.

For summary of safety and clinical data see above QR code.

EC REP MPS, Medical Product Service GmbH Borngasse 20 D-35619 Braunfels, Germany

CH REP MedEnvoy Switzerland Gotthardstrasse 28, 6302 Zug Switzerland

Model 8500

Instructions for Use

To set up and use the Nonin Model 8500 handheld pulse oximeter, please follow the simple instructions below.

Install Batteries

The Model 8500 is powered by six AA-size alkaline batteries. Insert the batteries as indicated inside the battery compartment. Proper battery positioning is essential for correct operation.

When batteries are critically low, the digital displays will go blank and the Pulse Quality Indicator will blink amber or red, but not green.

Power On and Off

The device automatically powers off after 10 minutes of inactivity.

Clinical Benefits

Nonin pulse oximeters allow for the management of patients' medical conditions by providing fast, accurate, real-time, noninvasive oxygen measurement in order to meet patients' medical needs.

Connect the Sensor

Connect the pulse oximeter sensor with the Nonin logo facing up to the top of the device as shown. Ensure the sensor is firmly plugged in.

Refer to sensor's Instructions for Use for sensor positioning information.

Taking Measurements

Verify the pulse oximeter sensor is properly positioned on the patient. If the Pulse Quality Indicator is blinking red or amber or is blinking erratically, reposition or replace the sensor. The SpO₂, and Pulse Rate readings will display a single dash until a valid pulse signal is detected, which takes about 5 seconds.

Diagram Description: Front view of the Nonin Model 8500 pulse oximeter showing the display with SpO2 and Pulse Rate, a Pulse Quality Indicator, an Advanced Dimmer Button, an ON button, and an OFF button.

Care and Maintenance

Clean the device separately from the sensors. For instructions on cleaning sensors, refer to the respective instructions for use.

Clean the device with a soft cloth dampened with isopropyl alcohol or a mild detergent. Do not pour or spray any liquids onto the device, and do not allow any liquid to enter any openings in the device. Allow the device to dry thoroughly before reusing.

Please refer to the Operator's Manual on nonin.com/support/8500 for troubleshooting guidance and more detailed operating instructions.

Model 8500

Instructions for Use

Thank you for trusting Nonin with your patients' healthcare needs. We sincerely appreciate your business. Please read your Operator's Manual carefully and direct any further questions to a Nonin Technical Service representative. If you would like to order products or check the status of a current order, please contact Customer Service.

Contact Customer Service or Technical Service

Toll Free: 800.356.8874 (U.S. and Canada only)

Phone: +1 763.553.9968

Email: customerservice@nonin.com

Nonin Medical Inc.

13700 1st Avenue North
Plymouth, MN 55441-5443, USA

Nonin B.V.

Doctor Paul Janssenweg 150
5026 RH Tilburg, Netherlands

Have other questions or want to learn more?

Visit nonin.com to read more about our history, product offerings, and more.

Nonin is committed to sustainable practices. This paper is made with FSC-certified materials, printed with soy ink, and is 100% recyclable.

8500 Specifications

*Additional specifications are available in the Operator's Manual that can be located using the QR Code.

Measurement Wavelengths and Output Power:

Indications for Use/Intended Use/Intended Purpose

Nonin Model 8500 Handheld Pulse Oximeter is indicated for use in measuring and displaying functional oxygen saturation of arterial hemoglobin (SpO₂) and pulse rate for adult, pediatric, and neonatal patients in hospitals, ambulatory, home, and EMS environments. Model 8500 is intended for continuous monitoring and/or spot-checking of patients when attended by a healthcare professional.

Warnings

Warnings (continued)

Cautions

This equipment complies with IEC 60601-1-2 for electromagnetic compatibility for medical electrical equipment and/or systems. This standard is designed to provide reasonable protection against harmful interference in a typical medical installation. However, because of the proliferation of radio-frequency transmitting equipment and other sources of electrical noise in healthcare and other environments, it is possible that high levels of such interference due to close proximity or strength of a source might disrupt the performance of this device. Medical electrical equipment needs special precautions regarding EMC, and all equipment must be installed and put into service according to the EMC information specified.

In compliance with the European Directive on Waste Electrical and Electronic Equipment (WEEE) 2002/96/EC, do not dispose of this product as unsorted municipal waste. This device contains WEEE materials; please contact your distributor regarding take-back or recycling of the device. If you are unsure how to reach your distributor, please call Nonin for your distributor's contact information.

This device is designed to determine the percentage of arterial oxygen saturation of functional hemoglobin. Factors that may degrade pulse oximeter performance or affect the accuracy of the measurement include the following:

When using the monitor in the home, avoid exposing the monitor to lint and dust.

When using the monitor around small children and pets, avoid leaving the monitor unattended. Cables pose a risk of injury, including strangulation.

A functional tester cannot be used to assess the accuracy of a pulse oximeter monitor or sensor.

All parts and accessories connected to the serial port of this device must be certified according to at least IEC Standard EN 60950, IEC 62368-1, or UL1950 for data-processing equipment.

This device is a precision electronic instrument and must be repaired by trained Nonin personnel only. Field repair of the device is not possible. Do not attempt to open the case or repair the electronics. Opening the case may damage the device and void the warranty.

Any sign or evidence of opening the system, field service by non-Nonin personnel, tampering, or any kind of misuse or abuse of the system, shall void the warranty in its entirety.

Failure of a network data coupling (serial cable/connectors) will result in loss of data transfer.

Adverse Event Statement

Users and/or patients should report adverse events involve their Nonin device to Nonin Medical, Inc. and the competent authority of the EU Member State in which the user and/or patient is established, if applicable.

©2022 Nonin Medical, Inc. All trademarks are the property of Nonin Medical, Inc. unless otherwise noted.

Models: 8500 Handheld Pulse Oximeter, 8500, Handheld Pulse Oximeter, Pulse Oximeter, Oximeter

File Info : application/pdf, 4 Pages, 339.61KB

PDF preview unavailable. Download the PDF instead.

8500-IFU

References

GPL Ghostscript 9.55.0 Adobe InDesign 18.0 (Macintosh)

Related Documents

Preview Nonin Model 9590 Fingertip Pulse Oximeter: Instructions for Use and Specifications
Official instructions for use, clinical benefits, specifications, cleaning procedures, warnings, and compliance information for the Nonin Onyx Vantage 9590 fingertip pulse oximeter.
Preview Nonin Model 7500 Pulse Oximeter Instructions for Use
Comprehensive instructions for the Nonin Model 7500 Pulse Oximeter, detailing setup, operation, indicators, alarms, and maintenance. Learn how to accurately measure oxygen saturation and pulse rate for various patient types.
Preview Nonin 7500FO Pulse Oximeter: Instructions for Use and Operator's Manual
Comprehensive instructions for setting up, operating, and maintaining the Nonin Model 7500FO Pulse Oximeter. Covers specifications, indications for use, warnings, cautions, operating procedures, indicators, alarms, maintenance, and troubleshooting.
Preview Nonin 2500A PalmSAT Pulse Oximeter Operator's Manual
Operator's manual for the Nonin 2500A PalmSAT Pulse Oximeter with Alarms, detailing its features, operation, maintenance, and troubleshooting.
Preview Nonin Model 7500 Quick Start-up Guide
Concise guide to setting up and operating the Nonin Model 7500 Pulse Oximeter, covering user-defined defaults, patient security mode, data collection, and memory clearing.
Preview Nonin Onyx Vantage 9590 Finger Pulse Oximeter: Instructions for Use and Specifications
Comprehensive instructions for use, care, maintenance, and specifications for the Nonin Onyx Vantage 9590 Finger Pulse Oximeter, a portable device for measuring SpO2 and pulse rate.
Preview Nonin Model 7500 Quick Start Guide
A quick start guide for the Nonin Model 7500 pulse oximeter, covering user settings, patient safety mode, data collection, and memory reset.
Preview Nonin Model 7500 Pulse Oximeter Quick Start Guide
Concise guide to setting up and operating the Nonin Model 7500 pulse oximeter, including parameter settings, safety mode, data management, and memory clearing. Learn how to configure default settings, activate/deactivate patient safety mode, collect and download data, and clear the device memory.