ONE
Internet controlled thermostat, ZigBee
EONEBATW EONEBATB Quick Guide
Ver. 1 Release date: II 2023

Product Compliance
This product complies with the following EU Directives: 2014/30/EU, 2014/35/EU, 2014/53/ EU, 2011/65/EU
SAFETY INFORMATION:
Use in accordance with national and EU regulations. Use the device only as intended, keeping it in a dry condition. The product is for indoor use only. Please read the entire manual, before installation or use.
WARNING:
This product must be used with a ZigBee EGATEZB gateway (purchased separately). Thermostat programming is done by ENGO Smart app.

Producer: Engo Controls S.C. 43-200 Pszczyna 3E Górnolska St. Poland
Distributor: QL CONTROLS Sp z o.o. Sp. k. 43-262 Kobielice 4 Rolna St. Poland
www.engocontrols.com

Product advantages:
Built-in Li-Ion 3,7V Battery
Communication in the ZigBee 3.0 standard
A multitude of functions available from ENGO Smart / Tuya Smart application
S1-S2 Input for additional sensor
NTC
ENGO ENGO binding function (devices connection BINDING in Online and Offline mode)

Wireless communication diagram
ZigBee 3.0
EONEBATW/B

WI-FI 2.4GHz
Gateway EGATEZB
ZigBee 3.0

ECB62ZB Control box

Connection description

EONEBATW/B S1

ZigBee 3.0

Li-lon
3.7V S2

Products sold separately

or

or

EMODZB Module

EREL1ZB12A Relay

Legend:
Temperature sensor S1, S2 Thermostat input for ext. temperature sensor
Connection with ZigBee 3.0 network Connection with WiFi 2.4GHz network

INTRODUCTION:
ONEBAT is a surface-mounted room thermostat which works over ZigBee technology. It has a built-in humidity sensor and a minimum/maximum setpoint temperature limiting function. The ONEBAT has the ability to work in heating or cooling modes. The unique feature of this thermostat is the possibility of wireless control over ENGO binding function. In order to have the ability to controll wirelessly, ONEBAT needs to be used with ENGO Smart / TUYA Smart mobile application and EGATEZB internet gateway (sold separately). ,,ENGO binding" function provides wireless and direct connection to the receivers (e.g. ECB62ZB control box, EMODZB module or EREL1ZB12A relay) over the EGATEZB gateway. After adding to the mobile app, thermostat offer more functions, e.g. push notifications or possibility of programming time schedules.

Technical Informations
Power supply Charging connector Temperature range Display temperature accuracy Control algorithm
Communication S1/S2 multifunctional input
IP protection class Dimension [mm]

Built-in Li-Ion 3,7V Battery USB type C, 5V DC 5,0°C - 45,0°C 0,5°C
TPI or Histeresis (from ±0,1°C to ±2°C) ZigBee 3.0 2,4GHz
Floor temp sensor, external air sensor, occupancy sensor IP30
90 x 90 x 14 mm

LCD Icon Description + Button Description

1

2

3

4

1

16 SET

5

15

6

14

2

7

8 3
9

12 10 13 11

1. "Up" Button 2. "OK" Button 3. "Down"Button

Button description

1. Current humidity reading 2. Current/Setpoint temperature 3. Clock 4. Temperature unit 5. Heating indicator (icon is animating when
there is heating demand) 6. Cooling indicator (icon is animating when
there is cooling demand) 7. Schedule mode icon 8. Temporary override mode 9. External/Floor or Occupancy sensor 10. Button lock 11. Holiday mode 12. Settings icon 13. Battery indicator 14. Receiver pairing indicator 15. ZigBee network connection indicator 16. Settings icon / temperature settings

Change the parameter value up

Change the parameter value down

Manual/Schedule mode - short button press (Online mode)

Enther the installer parameters- hold 3 seconds

Turn OFF/ON thermostat - hold 5 seconds

Enter the pairing mode - hold 5 seconds

+

Enter binding mode - hold 10 seconds

Thermostat factory reset - hold 15 seconds

+

Lock/Unlock thermostat keys - hold 3 seconds

+

Heating/Cooling mode change - hold 3seconds

Installation thermostat in the app
Make sure your router is within range of your smartphone. Make sure you are connected to the Internet. This will reduce the pairing time of the device.
STEP 1 - DOWNLOAD ENGO SMART APP
Download the ENGO Smart app from Google Play or Apple App Store and install it on your smartphone.

STEP 2 - REGISTER THE NEW ACCOUNT

To register a new account, please follow the steps below:

1

2

3

4

Click ,,Register" to create new account.

Enter your e-mail address to which the verification code will
be sent.

Enter the verification code received in the email.
Remember that you only have 60 seconds to enter
the code!!

Then set the login password.

STEP 3 - CONNECT THE THERMOSTAT TO ZigBee

5 sek. 5 sek.
5 sek.

Make sure ZigBee gateway has been added to the Engo Smart app.
1

Press and hold button for 5 seconds to turn ON EONE thermostat. When room temperature appears on the LCD, press and hold the and buttons for approx. 5 seconds until the display shows,,PA". Then release the keys. The pairing mode will start and counts the time back (180s).

2

3

In the app, click on upper right corner.

Select: ,,Add Device".

When the ZigBee gateway finds thermostat click the
,,Add" button.

4

5

6

Name the device and click,,Done".

The thermostat has been installed and displays the
main interface.

3
On the controller screen globe icon appeared stating that he has been he added to the ZigBee network.

Binding thermostat with the module/relay

Make sure that the module/relay and thermostat are in the same ZigBee network (they are added to the same gateway EGATEZB).

1

2

5x

10 sek.

or

5x
To properly link thermostat with the module/relay first click the button on the device 5 times.
The LED diode will start flashing slowly on red, which means the device is in binding mode.
3

10 sek.
On the EONE thermostat, hold and buttons until the "bind" message appears.
4

Release the keys, binding function process of linking thermostat with control box
is active.
5

The "binding" process takes up to 300 seconds.
6

3

After successfull binding operation ,,End" message will be displayed. LED on the module will stop flashing.
ATTENTION:

Both devices have been successfully linked. Thermostat displays the main screen, icon " " appeared on the screen indicating connection with the receiver (module/relay in this case).

If the binding process fails, it must be repeated taking into account the distances between devices, obstacles and local radio signal interferences.

Remember:
Radio range can be increased by Engo ZigBee repeaters.

Binding thermostat with the ECB62ZB wireless control box
Make sure that the ECB62ZB control box and thermostat are in the same ZigBee network (they are added to the same gateway EGATEZB) and the POWER LED lights up blue.
1

2

1

2

In order to correctly link thermostat with the control box, first select the zone in the control box with the SELECT button (1) (zone which you want to link with thermostat). The LED (2) will flash 3 times for the selected zone. Confirm your selection by clicking PAIR button (2). The LED (2) will flash green with the previously selected zone - binding process has started, it is active for 10 minutes and during this time you can link thermostat with the selected zone.

2

3

4

10 sek.

10 sek.

On the EONE thermostat, hold and buttons until the "bind"message appears.

Release the keys, binding functionprocess of linking thermostat with control box
is active.

The "binding" process takes up to 300 seconds.

5

6

ATTENTION:

After successfull binding operation ,,End" message
will be displayed.

If the binding process fails,

it must be repeated taking into

account the distances between
3 devices, obstacles and local radio signal interferences.

Remember:

Both devices have been successfully linked. Thermostat displays the main screen, icon " " appeared on the screen indicating connection with

Radio range can be increased by Engo ZigBee repeaters.

the receiver (ECB62ZB in this case).

Installer settings

To enter installer parameters press and hold button for 3 seconds.

1

2

5 sek.

Use or . button to move between parameters. Enter the parameter by . Edit the parameter using or . Confirm the new parameter value with the button.

Installer parameters

Pxx

Function

P01

Clock format

P02

Heating/Cooling Selection

P03

Control algorithm

P04

Offset temperature

P05

"Minimum setpoint"

P06

"Maximum setpoint"

P07

S1/S2 Input

Value 12h 24h
TPI UFH TPI RAD TPI ELE HIS 0.2 HIS 0.4 HIS 0.6 HIS 0.8 HIS 1.0 HIS 2.0 HIS 3.0 HIS 4.0
-3.5°C do +3.5°C
5°C - 45°C 5°C - 45°C
1 2 3 4

Desription
12 hour 24 hour Heating
Cooling TPI for Underfloor Heating
TPI for Radiators TPI for Electrical Heating
SPAN +/-0,1°C SPAN +/-0,2°C SPAN +/-0,3°C SPAN +/-0,4°C SPAN +/-0,5°C SPAN +/-1,0°C SPAN +/-1,5°C SPAN +/-2,0°C If the thermostat indicates wrong temperature, you can correct it by max ± 3.5°C" Minimum heating / cooling temperature that can be set
Maximum heating / cooling temperature that can be set Disable
External sensor as a floor sensor External sensor as an air sensor Occupnacy sensor (ON/OFF volt free input)

Default value 24h
TPI UFH for heating HIS 1.0 for
cooling
0°C 5°C 35°C 1

P08

Maximum floor temperature for heating (function active when P07=2)

5°C - 45°C

In order to protect the floor, the heating will be turned off, when the temperature of the floor sensor rises above the maximum value.

35°C

P09

Minimum floor temperature for heating (function active when P07=2)

5°C - 45°C

In order to protect the floor, the heating will be switched on, when the temperature of the floor sensor drops below the minimum value.

10°C

P10

Maximum floor temperature for cooling (function active when P07=2)

5°C - 45°C

In order to protect the floor, cooling will be switched on, when the temperature of the floor sensor exceeds the maximum value.

15°C

P11

Minimum floor temperature for cooling (function active when P07=2)

5°C - 45°C

In order to protect the floor, cooling will be turned off, when the temperature of the floor sensor drops below the minimum value

7°C

P12

Comfort warm floor

OFF

Level1=7min Thisfunctionhelpstokeepthefloorwarm, evenifthereisnoheating

Level 2 = 11min

demand from the room thermostat. This feature is available only for Heating Mode. User can select 5 levels of warm floor feature. Note that

Level3=15min comfortwarmfloorfunctionwillactivateheatingforspecifiedamount

OFF

Level4=19min oftime(inrelationtoLevelsettingchoosenbyuser).Heatingwillbe

Level 5 = 23min

activated only if in the past 1 hour heating was OFF.

ON

P13

Valve protection

OFF

Function disabled OFF
Function enabled

P14

Backlight brightness

10% - 100%

Adjustable in the range from 10 to 100%

50%

P15

PIN Code for settings access

NO

PIN

P16

Require a PIN to unlock the keys every time (function active when P15=PIN)

NO YES

NO

CLR

Clear settings factory reset

YES

Function disabled

NO

Function enabled

Function disabled NO
Function enabled

No action NO
Factory Reset

Factory reset
To RESET thermostat to factory settings, hold the and buttons for approx. 15 seconds. FA will be displayed. Then release the keys. Thermostat will restart, restore default (factory) settings and displays the home screen. The device will be removed from the ZigBee network you will need to add/pair it again.

1

2

3

10sek.

SET

10sek.



References