User Manual for ENGO CONTROLS models including: EONEBATW, EONEBATB, EONEBATW EONEBATB Internet Controlled Thermostat, EONEBATW, EONEBATB, EONEBATW Internet Controlled Thermostat, EONEBATB Internet Controlled Thermostat, Internet Controlled Thermostat, Internet Thermostat, Thermostat
Engo EONEBAT - UAB Paltaja Grupė
EONEBATW - ENGO
EONEBATWPROMOPACK EGATEZB - ENGO
File Info : application/pdf, 2 Pages, 1.61MB
DocumentDocumentONE Internet controlled thermostat, ZigBee EONEBATW EONEBATB Quick Guide Ver. 1 Release date: II 2023 Product Compliance This product complies with the following EU Directives: 2014/30/EU, 2014/35/EU, 2014/53/ EU, 2011/65/EU SAFETY INFORMATION: Use in accordance with national and EU regulations. Use the device only as intended, keeping it in a dry condition. The product is for indoor use only. Please read the entire manual, before installation or use. WARNING: This product must be used with a ZigBee EGATEZB gateway (purchased separately). Thermostat programming is done by ENGO Smart app. Producer: Engo Controls S.C. 43-200 Pszczyna 3E Górnolska St. Poland Distributor: QL CONTROLS Sp z o.o. Sp. k. 43-262 Kobielice 4 Rolna St. Poland www.engocontrols.com Product advantages: Built-in Li-Ion 3,7V Battery Communication in the ZigBee 3.0 standard A multitude of functions available from ENGO Smart / Tuya Smart application S1-S2 Input for additional sensor NTC ENGO ENGO binding function (devices connection BINDING in Online and Offline mode) Wireless communication diagram ZigBee 3.0 EONEBATW/B WI-FI 2.4GHz Gateway EGATEZB ZigBee 3.0 ECB62ZB Control box Connection description EONEBATW/B S1 ZigBee 3.0 Li-lon 3.7V S2 Products sold separately or or EMODZB Module EREL1ZB12A Relay Legend: Temperature sensor S1, S2 Thermostat input for ext. temperature sensor Connection with ZigBee 3.0 network Connection with WiFi 2.4GHz network INTRODUCTION: ONEBAT is a surface-mounted room thermostat which works over ZigBee technology. It has a built-in humidity sensor and a minimum/maximum setpoint temperature limiting function. The ONEBAT has the ability to work in heating or cooling modes. The unique feature of this thermostat is the possibility of wireless control over ENGO binding function. In order to have the ability to controll wirelessly, ONEBAT needs to be used with ENGO Smart / TUYA Smart mobile application and EGATEZB internet gateway (sold separately). ,,ENGO binding" function provides wireless and direct connection to the receivers (e.g. ECB62ZB control box, EMODZB module or EREL1ZB12A relay) over the EGATEZB gateway. After adding to the mobile app, thermostat offer more functions, e.g. push notifications or possibility of programming time schedules. Technical Informations Power supply Charging connector Temperature range Display temperature accuracy Control algorithm Communication S1/S2 multifunctional input IP protection class Dimension [mm] Built-in Li-Ion 3,7V Battery USB type C, 5V DC 5,0°C - 45,0°C 0,5°C TPI or Histeresis (from ±0,1°C to ±2°C) ZigBee 3.0 2,4GHz Floor temp sensor, external air sensor, occupancy sensor IP30 90 x 90 x 14 mm LCD Icon Description + Button Description 1 2 3 4 1 16 SET 5 15 6 14 2 7 8 3 9 12 10 13 11 1. "Up" Button 2. "OK" Button 3. "Down"Button Button description 1. Current humidity reading 2. Current/Setpoint temperature 3. Clock 4. Temperature unit 5. Heating indicator (icon is animating when there is heating demand) 6. Cooling indicator (icon is animating when there is cooling demand) 7. Schedule mode icon 8. Temporary override mode 9. External/Floor or Occupancy sensor 10. Button lock 11. Holiday mode 12. Settings icon 13. Battery indicator 14. Receiver pairing indicator 15. ZigBee network connection indicator 16. Settings icon / temperature settings Change the parameter value up Change the parameter value down Manual/Schedule mode - short button press (Online mode) Enther the installer parameters- hold 3 seconds Turn OFF/ON thermostat - hold 5 seconds Enter the pairing mode - hold 5 seconds + Enter binding mode - hold 10 seconds Thermostat factory reset - hold 15 seconds + Lock/Unlock thermostat keys - hold 3 seconds + Heating/Cooling mode change - hold 3seconds Installation thermostat in the app Make sure your router is within range of your smartphone. Make sure you are connected to the Internet. This will reduce the pairing time of the device. STEP 1 - DOWNLOAD ENGO SMART APP Download the ENGO Smart app from Google Play or Apple App Store and install it on your smartphone. STEP 2 - REGISTER THE NEW ACCOUNT To register a new account, please follow the steps below: 1 2 3 4 Click ,,Register" to create new account. Enter your e-mail address to which the verification code will be sent. Enter the verification code received in the email. Remember that you only have 60 seconds to enter the code!! Then set the login password. STEP 3 - CONNECT THE THERMOSTAT TO ZigBee 5 sek. 5 sek. 5 sek. Make sure ZigBee gateway has been added to the Engo Smart app. 1 Press and hold button for 5 seconds to turn ON EONE thermostat. When room temperature appears on the LCD, press and hold the and buttons for approx. 5 seconds until the display shows,,PA". Then release the keys. The pairing mode will start and counts the time back (180s). 2 3 In the app, click on upper right corner. Select: ,,Add Device". When the ZigBee gateway finds thermostat click the ,,Add" button. 4 5 6 Name the device and click,,Done". The thermostat has been installed and displays the main interface. 3 On the controller screen globe icon appeared stating that he has been he added to the ZigBee network. Binding thermostat with the module/relay Make sure that the module/relay and thermostat are in the same ZigBee network (they are added to the same gateway EGATEZB). 1 2 5x 10 sek. or 5x To properly link thermostat with the module/relay first click the button on the device 5 times. The LED diode will start flashing slowly on red, which means the device is in binding mode. 3 10 sek. On the EONE thermostat, hold and buttons until the "bind" message appears. 4 Release the keys, binding function process of linking thermostat with control box is active. 5 The "binding" process takes up to 300 seconds. 6 3 After successfull binding operation ,,End" message will be displayed. LED on the module will stop flashing. ATTENTION: Both devices have been successfully linked. Thermostat displays the main screen, icon " " appeared on the screen indicating connection with the receiver (module/relay in this case). If the binding process fails, it must be repeated taking into account the distances between devices, obstacles and local radio signal interferences. Remember: Radio range can be increased by Engo ZigBee repeaters. Binding thermostat with the ECB62ZB wireless control box Make sure that the ECB62ZB control box and thermostat are in the same ZigBee network (they are added to the same gateway EGATEZB) and the POWER LED lights up blue. 1 2 1 2 In order to correctly link thermostat with the control box, first select the zone in the control box with the SELECT button (1) (zone which you want to link with thermostat). The LED (2) will flash 3 times for the selected zone. Confirm your selection by clicking PAIR button (2). The LED (2) will flash green with the previously selected zone - binding process has started, it is active for 10 minutes and during this time you can link thermostat with the selected zone. 2 3 4 10 sek. 10 sek. On the EONE thermostat, hold and buttons until the "bind"message appears. Release the keys, binding functionprocess of linking thermostat with control box is active. The "binding" process takes up to 300 seconds. 5 6 ATTENTION: After successfull binding operation ,,End" message will be displayed. If the binding process fails, it must be repeated taking into account the distances between 3 devices, obstacles and local radio signal interferences. Remember: Both devices have been successfully linked. Thermostat displays the main screen, icon " " appeared on the screen indicating connection with Radio range can be increased by Engo ZigBee repeaters. the receiver (ECB62ZB in this case). Installer settings To enter installer parameters press and hold button for 3 seconds. 1 2 5 sek. Use or . button to move between parameters. Enter the parameter by . Edit the parameter using or . Confirm the new parameter value with the button. Installer parameters Pxx Function P01 Clock format P02 Heating/Cooling Selection P03 Control algorithm P04 Offset temperature P05 "Minimum setpoint" P06 "Maximum setpoint" P07 S1/S2 Input Value 12h 24h TPI UFH TPI RAD TPI ELE HIS 0.2 HIS 0.4 HIS 0.6 HIS 0.8 HIS 1.0 HIS 2.0 HIS 3.0 HIS 4.0 -3.5°C do +3.5°C 5°C - 45°C 5°C - 45°C 1 2 3 4 Desription 12 hour 24 hour Heating Cooling TPI for Underfloor Heating TPI for Radiators TPI for Electrical Heating SPAN +/-0,1°C SPAN +/-0,2°C SPAN +/-0,3°C SPAN +/-0,4°C SPAN +/-0,5°C SPAN +/-1,0°C SPAN +/-1,5°C SPAN +/-2,0°C If the thermostat indicates wrong temperature, you can correct it by max ± 3.5°C" Minimum heating / cooling temperature that can be set Maximum heating / cooling temperature that can be set Disable External sensor as a floor sensor External sensor as an air sensor Occupnacy sensor (ON/OFF volt free input) Default value 24h TPI UFH for heating HIS 1.0 for cooling 0°C 5°C 35°C 1 P08 Maximum floor temperature for heating (function active when P07=2) 5°C - 45°C In order to protect the floor, the heating will be turned off, when the temperature of the floor sensor rises above the maximum value. 35°C P09 Minimum floor temperature for heating (function active when P07=2) 5°C - 45°C In order to protect the floor, the heating will be switched on, when the temperature of the floor sensor drops below the minimum value. 10°C P10 Maximum floor temperature for cooling (function active when P07=2) 5°C - 45°C In order to protect the floor, cooling will be switched on, when the temperature of the floor sensor exceeds the maximum value. 15°C P11 Minimum floor temperature for cooling (function active when P07=2) 5°C - 45°C In order to protect the floor, cooling will be turned off, when the temperature of the floor sensor drops below the minimum value 7°C P12 Comfort warm floor OFF Level1=7min Thisfunctionhelpstokeepthefloorwarm, evenifthereisnoheating Level 2 = 11min demand from the room thermostat. This feature is available only for Heating Mode. User can select 5 levels of warm floor feature. Note that Level3=15min comfortwarmfloorfunctionwillactivateheatingforspecifiedamount OFF Level4=19min oftime(inrelationtoLevelsettingchoosenbyuser).Heatingwillbe Level 5 = 23min activated only if in the past 1 hour heating was OFF. ON P13 Valve protection OFF Function disabled OFF Function enabled P14 Backlight brightness 10% - 100% Adjustable in the range from 10 to 100% 50% P15 PIN Code for settings access NO PIN P16 Require a PIN to unlock the keys every time (function active when P15=PIN) NO YES NO CLR Clear settings factory reset YES Function disabled NO Function enabled Function disabled NO Function enabled No action NO Factory Reset Factory reset To RESET thermostat to factory settings, hold the and buttons for approx. 15 seconds. FA will be displayed. Then release the keys. Thermostat will restart, restore default (factory) settings and displays the home screen. The device will be removed from the ZigBee network you will need to add/pair it again. 1 2 3 10sek. SET 10sek.