LiftMaster STAR1000 Commercial Access Control Receiver

Application

The STAR1000 is a high capacity single channel commercial access control receiver for commercial door operators and dry contact triggered devices. The STAR1000 is compatible with Security+ 2.0™ remote controls and wireless keyless entries, Security+ 2.0™ Passport and Passport Lite remote controls. This receiver is compatible with HomeLink®. For programming or compatibility information, visit www.homelink.com. The receiver capacity is 1,000 devices and can be any combination of remote controls and wireless keyless entries. The receiver is watertight according to IPX44 specification.

Installation

  1. Select Location

    Select a convenient location near the operator to be controlled by the receiver within "line of sight" of the intended transmitting location. Note: Do not mount the LCD screen in direct sunlight. Avoid mounting the receiver in a metal enclosure or near other wireless receiving or transmitting devices.

  2. Mount Bracket

    Mount the bracket to the desired surface with appropriate hardware (not provided) (See Figure 1).

  3. Prepare Receiver

    Remove the 4 (#8) screws on the back of the receiver and remove the faceplate. Unplug the keypad connector from the control board. Note: Be careful not to damage the keypad cable while removing the faceplate.

  4. Make Wiring Connections

    Make wiring connections (See Figure 2). Refer to your gate or commercial door operator owner's manual for more specific information.

  5. Reconnect Keypad

    Reconnect the keypad connector to the board (labeled J9).

  6. Secure Faceplate

    Secure the faceplate with the 4 (#8) screws previously removed.

  7. Install Antenna

    Install the antenna provided. Note: Use the optional 86LM or 86LMT antenna extension kit (see page 4) to mount the remote antenna as high and far from metallic objects as possible for best radio range.

  8. Mount Receiver

    Snap the receiver onto the mounting bracket and secure with the (#8) screws provided.

  9. Seal Wiring

    Tighten the watertight connector to secure and seal the wiring.

Figure 1: Receiver Components

Figure 1 illustrates the components of the STAR1000 receiver. It shows the Keypad Connector, Backup Memory Module, Antenna Connector, Mounting Bracket, and Watertight Connector. The receiver is shown without its faceplate.

Figure 2: Wiring Diagram

Figure 2 depicts the wiring connections for the STAR1000 receiver. It shows the Power Connection and Relay Connection terminals. The diagram illustrates the receiver connected to a 9-30 Volts AC/DC, 250 mA max Power Supply, a Control Station, and a Single Operator. It also indicates the Receiver without Faceplate.

Safety Warnings

WARNING: To prevent possible SERIOUS INJURY or DEATH from electrocution, be sure power is NOT connected BEFORE installing the receiver.

WARNING: To prevent possible SERIOUS INJURY or DEATH from a moving gate or garage door:

  • ALWAYS keep remote controls out of reach of children. NEVER permit children to operate, or play with remote control transmitters.
  • Activate gate or door ONLY when it can be seen clearly, is properly adjusted, and there are no obstructions to door travel.
  • ALWAYS keep gate or garage door in sight until completely closed. NEVER permit anyone to cross path of moving gate or door.

WARNING: To prevent possible SERIOUS INJURY or DEATH, the use of CONSTANT OPERATION on residential openers is PROHIBITED. When a receiver is used to activate a commercial door opener, a reversing edge MUST be installed on the bottom of the door. Failure to install a reversing edge under these circumstances may result in SERIOUS INJURY or DEATH to persons trapped beneath the door.

User Interface

The STAR1000 user interface consists of a 22-character by 5-line LCD display, 3 "soft keys", Down/Up arrows, and a numeric keypad.

  • LCD Display: Shows system programming and status.
  • Line 1: Menu and function mode.
  • Lines 2, 3, and 4: Menu selections and data.
  • Line 5: Soft key function modes.
  • Soft Keys: Functions are defined by the label on line 5 of the display and change according to menu selection.
  • Down/Up Keys: Used for navigation in the menus.
  • Numeric Keypad: Used for entering numeric data.
  • Scroll Indicator: Appears on the left margin of lines 2, 3, and 4 if more than 3 options exist, showing relative position within the list.
  • Antenna Connection: For the direct antenna or an antenna extension kit.
  • Menu/Data Selection: Shown in inverse font.

Programming

The receiver can learn a combination of up to 1,000 remote control transmitters and keyless entries. Audible and visual warnings occur when capacity is exceeded. After 30 seconds of inactivity, the receiver times out and the LiftMaster® logo is displayed. Select "UNLOCK" and enter the PIN to continue.

Initial PIN Setup

The PIN restricts access to authorized administrators only. If omitted, anyone can program the receiver. Upon initial power-up, the system firmware revision is displayed for 5 seconds, followed by the LiftMaster® logo. Pressing a key displays "CREATE PIN?".

  1. Press "YES" to create a PIN.
  2. If the PIN is lost, request a reset code by pressing "RESET." You will be provided with a 5-digit serial number. Log in to the partner portal at https://partner.liftmaster.com/utility and enter the Serial Number to retrieve the master code.
  3. Enter a 6-digit PIN, then press "YES". Enter the 6-digit PIN a second time and press "YES" to program the PIN. Press "CLEAR" to correct errors. Select "BACK" to exit the PIN entry screen.
  4. Once the 6-digit PIN is programmed, the LCD reads "KEYPAD UNLOCKED". Select "OK" to proceed to the Main Menu. After 30 seconds of inactivity, the receiver times out and the LiftMaster® logo is displayed. Select "UNLOCK" and enter the PIN to continue.

Note: Resetting the PIN does not clear data or settings on the STAR1000 and PPWR.

Programming Commands

MenuCommandDescription
MAIN MENULEARN DEVICEProgram a device to the receiver.
BLOCK LEARN DEVICEBlock program a range of devices to the receiver.
LEARN TO LOC #Program a device to a 4-digit number location.
DELETE MENUDELETE DEVICEDelete a specified device that has been programmed to the receiver.
DELETE ALL DEVICESDelete all programmed devices.
SUSPEND MENUSUSPEND DEVICETemporarily disables the function of a specified device that has been programmed to the receiver.
SUSPEND ALL DEVICESTemporarily disables the function of ALL devices programmed to the receiver.
UNSUSPEND DEVICERe-enable the function of a suspended device.
UNSUSPEND ALL DEVICESRe-enable the function of ALL suspended devices.
QUERY MENULOC # USEDDisplays a range of used locations starting from a specified location.
LOC # AVAILABLEDisplays a range of empty locations starting from a specified location.
LOC # SUSPENDEDDisplays a range of suspended locations starting from a specified location.
SETTINGSCHANGE PINChange the 6-digit PIN number for the receiver.
DEALER INFODisplay and edit the dealer 11-digit contact phone number.
FIRMWARE VERSIONDisplays the current firmware version.
BEEPTurn the audible feedback on or off.
MEMORYDUPLICATE MEMORYCreates a memory backup. A backup memory module must be installed.
RESTORE MEMORYRestores a memory backup from a memory module. Note: Content of memory backup module will over-write any information already stored in the receiver memory.
RELAYSets the relay activation time from .25 to 1 second.
CONTRASTPress Down or Up arrows to adjust LCD contrast.
LANGUAGESets menu language: English (Default), Spanish, and French.
FACTORY DEFAULTReset receiver to factory default settings.

Diagnostics

The receiver emits a series of audible beeps to signal programming and error events. The On/Off column indicates that the audible notification for the event may be disabled in the BEEP SETTINGS menu.

EventAudible NotificationsOn/Off
Key pressSingleYES
Successful AddDouble
Successful DeleteTriple
Successful SuspendDouble
Successful UnsuspendDouble
Master PIN entry errorLong
Programming errorLong
Location out of rangeLong
Generic SuccessDouble
Generic ErrorLong
Received unknown TxSlowYES
Received known TxDoubleYES
Received known suspended TxLongYES

Specifications

System Capacity1000 devices
Supply Voltage9 - 30 Volts AC, 9 - 42 Volts DC
Operating Current50 mA Maximum
Stand By Current30 mA Maximum
Surge Suppression6.0 kV Min
Operating Temp Range-40°C to +65°C @ 50% Rh, -40°F to +149°F @ 50% Rh
Storage and Shipping Temp Range-40°C to +85°C @ 50% Rh
Code FormatSecurity+ 2.0™ Only
Relay Contact Rating1 amp @ 24V AC/DC

Compatible Accessories

Remote Controls892LT, 894LT, 891LM, 893LM, 890MAX, 893MAX, PPV3M, PPK3M, PPK3PHM, PPLV1-xxx, PPLK1-xxx, PPLK1PH-xxx
Keypads877LM, 877MAX, and 878MAX
Antenna Extension Kits:
   15' Extension Kits86LM
   25' Extension Kits86LMT
24VAC Transformer for screw terminals95LM

Repair Parts

AntennaK76-36681
Mounting BracketK13-36651-1

Notice

To comply with FCC and/or Industry Canada rules (IC), adjustment or modifications of this receiver and/or transmitter are prohibited, except for changing the code setting or replacing the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS. Tested to Comply with FCC Standards for Home or office use. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Technical Support

For technical support, dial our toll-free number: 1-800-528-2806

Models: STAR1000, Commercial Access Control Receiver, Access Control Receiver, Commercial Control Receiver, Control Receiver, Receiver

File Info : application/pdf, 12 Pages, 1.47MB

PDF preview unavailable. Download the PDF instead.

114-5680-000 Adobe PDF Library 16.0.3

Related Documents

Preview LiftMaster STAR1000 Commercial Access Control Receiver Manual
This document provides detailed instructions and specifications for the LiftMaster STAR1000 Commercial Access Control Receiver, including installation, programming, and troubleshooting.
Preview LiftMaster STAR1000 Commercial Access Control Receiver Installation and User Manual
Comprehensive guide for installing, programming, and operating the LiftMaster STAR1000 commercial access control receiver. Covers user interface, commands, diagnostics, specifications, and compatible accessories.
Preview LiftMaster 850LM, 860LM Universal Receivers and 811LM, 813LM Commercial Remote Controls Product Guide
A comprehensive product guide detailing LiftMaster's 850LM, 860LM universal receivers and 811LM, 813LM commercial remote controls. Covers features, compatibility, specifications, dimensions, and shipping information for commercial access control solutions.
Preview LiftMaster 850LM/850LMC 3-Channel Universal Receiver Installation and Operation Manual
Comprehensive guide to installing, wiring, programming, and operating the LiftMaster 850LM and 850LMC 3-Channel Universal Receiver for gates and commercial door operators.
Preview LiftMaster 850LM/860LM/811LM/813LM Universal Receivers and Commercial Remote Controls Product Guide
This guide details the LiftMaster 850LM, 860LM universal receivers and 811LM, 813LM commercial remote controls. It covers features, compatibility, specifications, and shipping information for advanced access control solutions in commercial and gated environments.
Preview LiftMaster 850LM 3-Channel Universal Receiver Installation and Programming Guide
This guide provides detailed instructions for the installation, wiring, and programming of the LiftMaster 850LM 3-Channel Universal Receiver. Learn how to connect the receiver to commercial door operators, program remote controls, and understand safety warnings.
Preview LiftMaster 892LT and 894LT Remote Controls User Guide
Learn how to program and use your LiftMaster 892LT and 894LT remote controls for garage door openers, gate operators, and commercial door operators. Includes safety warnings, programming options, and warranty information.
Preview LiftMaster Logic 5.0 DJ Jackshaft Commercial Door Operator
Comprehensive product guide detailing the LiftMaster Logic 5.0 DJ Jackshaft Commercial Door Operator, highlighting its industrial-duty applications, smart features, safety mechanisms, reliability, entrapment protection options, and detailed technical specifications.