Friedrich Breeze Universal Heat Pumps

Product Submittal Document

Overview

The Friedrich Breeze™ Universal Heat Pump systems offer versatile compatibility with existing air handlers or gas furnaces, designed for efficient heating and cooling. These systems feature advanced inverter technology for high efficiency and operation in extreme temperatures.

Key Features

Available Models

Indoor Units (Air Handlers)

Outdoor Units (Inverter Heat Pump Condensers)

Heater Kits

Specifications

CategorySub-Category2-Ton (FPHFA24A3D/FPHFR24A3D)3-Ton (FPHFA36A3D/FPHFR36A3D)4-Ton (FPHFA48A3D/FPHFR48A3D)
SYSTEM COMPONENTSIndoor ModelFPHFA24A3DFPHFA36A3DFPHFA48A3D
Outdoor ModelFPHFR24A3DFPHFR36A3DFPHFR48A3D
ENERGY STAR® StandardYYY
ENVIRONMENTALENERGY STAR® Cold ClimateYYY
A2L SensorYYY
Power Supply208~230/60/1208-230/60/1208~230/60/1
ELECTRICALRated Current - Indoor (A)9.41418.8
Thermostat TypeWiredWiredWired
Rated Current - Outdoor (A)8.71317.8
MCA - Outdoor (A)223037
COOLING PERFORMANCEMax. Circuit Breaker (A)305050
Communication Cable4 × 18AWG4 × 18AWG4 × 18AWG
Rated Capacity @ 95°F (Btu/h)24,00036,00048,000
Cooling Capacity Range (Min.-Max.) (Btu/h)10,500-31,00012,000-45,00016,800-61,000
Cooling Capacity Range (Min.-Max.) (W)3,077-9,0853,517-13,1894,924-17,878
Capacity @ 115°F (Btu/h)19,20028,80038,400
Power Input (W)2,0503,0704,100
Current (A)9.41418.8
EER2 @ 95°F (Btu/h/W)11.711.711.7
SEER2 (Btu/h/W)181919
Operating Temp. Range - Indoor (°F (°C))61-86 (16-30)61-86 (16-30)61-86 (16-30)
Operating Temp. Range - Outdoor (°F (°C))5-125 (-15-52)5-125 (-15-52)5-125 (-15-52)
HEATING PERFORMANCERated Capacity at 47° (Btu/h)24,00036,00048,000
Heating Capacity Range (Min.-Max.) (Btu/h)11,700-33,00011,000-45,00015,800-65,000
Heating Capacity Range (Min.-Max.) (W)3,428-9,6703,324-13,1894,630-19,050
Power Input (W)1,9002,8003,900
Current (A)8.71317.8
COP @ 47° (W/W)3.73.773.6
COP @ 5° (W/W)1.921.8
HSPF2 (Btu/h/W)1099
Rated Heating Capacity @ 17°F (-8.3°C) (Btu/h)18,50026,00034,000
Max. Heating Capacity @ 17°F (-8.3°C) (Btu/h)24,00036,00048,000
Max. Heating Capacity @ 5°F (-15°C) (Btu/h)24,00036,00048,000
Max. Heating Capacity @ -5°F (-20.5°C) (Btu/h)16,80028,80038,000
Max. Heating Capacity @ -13°F (-25°C) (Btu/h)14,40025,20033,600
Max. Heating Capacity @ -22°F (-30°C) (Btu/h)10,00013,00015,000
Operating Temp. Range - Indoor (°F (°C))61-86 (16-30)61-86 (16-30)61-86 (16-30)
Operating Temp. Range - Outdoor (°F (°C))-13-75 (-25-24)-13-75 (-25-24)-13-75 (-25-24)
INDOOR FAN MOTOROutput (HP)1/27/81/5
RLA (A)2.63.81
Speed (r/min.)350-1,400350-1,400350-1,400
Indoor Airflow Rated (CFM (m³/h))800 (1,360)1,118 (1,900)1,600 (2,720)
Indoor Airflow (Min.-Max.) (CFM (m³/h))529-823 (900-1,400)736-1,176 (1,250-2,000)1,058-1,647 (1,800-2,800)
Indoor Airflow Ultra-low Speed (CFM (m³/h))529 (900)736 (1,250)1,058 (1,800)
STATIC PRESSURERated (in. W.C. (Pa))0.58 (145)0.58 (145)0.58 (145)
Range (in. W.C. (Pa))0-0.8 (200)0-0.8 (200)0-0.8 (200)
OUTDOOR FAN MOTOROutput (HP)1/71/31/5
RLA (A)0.81.51
Speed (r/min.)880850890
Outdoor Airflow (High) (CFM (m³/h))2,235 (3,800)3,350 (5,700)4,820 (8,200)
COMPRESSORInput (W)2,5753,8005,830
Rated Current (A)10.814.621.2
Compressor TypeFV68S/900FV68S/1,200VG75/1,700
Refrigerant Oil (ml)88.1 (2.3)112.9 (3.2)169.3 (4.8)
Refrigerant Charge (oz. (kg))25 (7.5)25 (7.5)25 (7.5)
REFRIGERANT (R-454B)Factory Pre-charge (ft. (m))25 (7.5)25 (7.5)25 (7.5)
Additional Charge for Each ft. (oz./ft.)0.380.380.38
Liquid Side / Gas Side (in. (mm))3/8" / 5/8" (Φ9.52 / Φ15.88)3/8" / 5/8" (Φ9.52 / Φ15.88)3/8" / 3/4" (Φ9.52 / Φ19.05)
Max. Pipe Length (ft. (m))164 (50)164 (50)246 (75)
Max. Difference in Level (ft. (m))98 (30)98 (30)98 (30)
Design Pressure (H/L) (PSIG (MPa))600/415 (4.14/2.86)600/415 (4.14/2.86)600/415 (4.14/2.86)
MISC.Indoor Noise Level (High) (dB(A))516062
Drainage Water Pipe Diameter (in.)1-1/4"1-1/4"1-1/4"
Outdoor Throttle TypeEEVEEVEEV
Moisture Removal (pints/hr (L/hr))4.64 (2.2)8.5 (4)13.15 (6.23)
NET DIMENSIONS & WEIGHTSIndoor Unit Dimensions (W×H×D) (in.)17-4/8×45×2119-5/8×46-1/8×21-5/822×53-7/8×24
Indoor Unit Dimensions (W×H×D) (mm)445×1,143×534500×1,170×550560×1,370×610
Indoor Unit Net Weight (lbs. (kg))130.5 (59.2)135.1 (61.3)180.6 (82)
Indoor Unit Shipping Weight (lbs. (kg))153.6 (69.7)158.1 (71.7)204.4 (92.7)
Outdoor Unit Dimensions (W×H×D) (in.)35-3/8×29-4/8×13-3/843-2/8×34-4/8×17-6/838-3/8×57-4/8×13
Outdoor Unit Dimensions (W×H×D) (mm)900×750×3401,100×875×450975×1,460×330
Outdoor Unit Net Weight (lbs. (kg))123.4 (56)185.2 (84)244.7 (111)
Outdoor Unit Shipping Weight (lbs. (kg))132.3 (60)209.4 (95)266.8 (121)

Note: Pipe lengths over 100 feet require an increase in communication cable to 16 AWG. Lengths over 262 feet require an increase in communication cable to 14 AWG.

Indoor Unit Dimensions

FPHFA24A3D (2-Ton)

Overall Dimensions (W×H×D): 17-1/2 (445mm) × 45 (1143mm) × 21 (534mm). Key connection points include a drain pipe, gas pipe, and liquid pipe. An electric box is located on the side. Air inlet and outlet are at the top.

Detailed Dimensions:

FPHFA36A3D (3-Ton)

Overall Dimensions (W×H×D): 19-5/8 (500mm) × 46 (1170mm) × 21-5/8 (550mm). Key connection points include a drain pipe, gas pipe, and liquid pipe. An electric box is located on the side. Air outlet is at the top.

Detailed Dimensions:

FPHFA48A3D (4-Ton)

Overall Dimensions (W×H×D): 22 (560mm) × 53-7/8 (1370mm) × 24-1/8 (612mm). Key connection points include a drain pipe, gas pipe, and liquid pipe. An electric box is located on the side. Air inlet and outlet are at the top.

Detailed Dimensions:

Outdoor Unit Dimensions

FPHFR24A3D (2-Ton)

Overall Dimensions (W×H×D): 35-3/8 (900mm) × 29-1/2 (750mm) × 13-3/8 (340mm). Features include an air inlet and outlet, drain pipe, gas pipe, and liquid pipe connections, and an electric box.

Detailed Dimensions:

FPHFR36A3D (3-Ton)

Overall Dimensions (W×H×D): 43-3/8 (1100mm) × 34-1/2 (875mm) × 17-3/4 (450mm). Features include an air inlet and outlet, drain pipe, gas pipe, and liquid pipe connections, and an electric box.

Detailed Dimensions:

FPHFR48A3D (4-Ton)

Overall Dimensions (W×H×D): 38-3/8 (975mm) × 57-1/2 (1460mm) × 13 (330mm). Features include an air inlet and outlet, drain pipe, gas pipe, and liquid pipe connections, and an electric box.

Detailed Dimensions:

Important Notes

System rated performance is only guaranteed when paired with a properly installed Friedrich air handler. Performance may be diminished when paired with a non-Friedrich air handler, and eligibility for rebates may be voided. Due to continuing research in new energy-saving technology, specifications are subject to change without notice.

High Efficiency Electric Home Rebates are dependent on state participation and available funding. Visit Friedrich.com/Federal-Incentives for complete details.

© 2024 Friedrich Air Conditioning. Friedrich trademarks are owned by Friedrich Air Conditioning LLC.

PDF preview unavailable. Download the PDF instead.

BREEZE PREMIER SUBMITTAL (REV 08-05-25) Adobe InDesign 20.3 (Macintosh) Adobe PDF Library 17.0

Related Documents

Preview Friedrich Breeze Series Inverter Heat Pumps for Efficient Home Comfort
Discover the Friedrich Breeze Series inverter-driven universal ducted heat pumps, offering precise temperature control, significant energy savings, and quiet operation for year-round home comfort. Learn about Premier and Select models, universal compatibility, and advanced features.
Preview Friedrich Breeze Universal Heat Pumps: Specifications and Dimensions
Comprehensive submittal sheet for Friedrich Breeze Universal Heat Pumps, detailing features, specifications, and dimensions for 2-ton to 5-ton models, including indoor and outdoor units.
Preview Friedrich Universal Heat Pump Capacity and Selection Data for R-454B Refrigerant
Comprehensive capacity and selection data for Friedrich Universal Heat Pumps (24k-48k BTU) with R-454B refrigerant. Includes detailed cooling and heating capacity tables, piping length correction factors, height difference correction factors, and defrosting operation adjustments.
Preview Friedrich Breeze Select 2025 R-454B Heat Pump Quick Start Guide
A quick start guide for Friedrich Breeze Select 2025 R-454B Universal Heat Pump models, covering installation, operation, and troubleshooting.
Preview Friedrich Breeze Universal Heat Pump: Installation and Wiring Diagrams
Comprehensive guide to the Friedrich Breeze Universal Heat Pump, covering installation, wiring diagrams for various configurations, and operational parameters. Learn about its features, energy savings, and low-temperature performance.
Preview Friedrich Endeavor™ F-Series Plus iM Heat Pumps: Specifications and Performance Data
Detailed specifications, features, performance data, and model information for the Friedrich Endeavor™ F-Series Plus iM Heat Pumps (FRP15AZ series). Includes efficiency ratings, capacities, dimensions, and warranty details.
Preview Friedrich VRP Variable Refrigerant Packaged Heat Pump Product Profile
Discover the Friedrich VRP, an innovative and intelligent Variable Refrigerant Packaged Heat Pump system. It provides superior cooling, efficient heating, advanced humidity control, and optional fresh air integration, ensuring optimal comfort and energy savings with its Precision Inverter technology.
Preview Friedrich VRP: Variable Refrigerant Packaged Heat Pumps for Lodging & Multifamily
Explore the Friedrich VRP series, offering VRF performance with single-package simplicity. Discover advanced features like Precision Inverter technology, low-ambient heating, superior humidity control, and IAQ solutions for lodging and multifamily applications.