Ethernet Expansion Card (CIOv) for BladeCenter

Product Guide (withdrawn product)

The Ethernet Expansion Card (CIOv) is an Ethernet expansion card with two 1 Gb Ethernet ports designed for BladeCenter servers with CIOv expansion slots. It is based on proven Broadcom 5709S ASIC technology and offers value added features like TCP Offload (TOE) and software-based iSCSI support for high performance.

This card is installed into the CIOv slot of the supported blade server. It provides connections to Ethernet-compatible modules located in bays 3 and 4 of supported BladeCenter chassis. The CIOv slot is a second generation PCI Express x8 slot. A maximum of one Ethernet Expansion Card (CIOv) is supported per single-wide blade server.

The Ethernet Expansion Card (CIOv) is shown in Figure 1.

Did you know?

Today's virtualized servers require a larger number of network adapters. This adapter is a perfect fit for these environments because it can enable up to eight Ethernet ports per blade server.

The adapter is based on the PCI Express bus, which can be thought of as a high-speed serial replacement of the older technology. Its use offers many benefits including higher speeds and the ability to send and receive data at the same time.

When using the CIOv adapter, you can simultaneously use a CFFh adapter to enable more types of I/O to supported blade servers such as the HS22 when installed in the IBM BladeCenter H chassis. The innovative design of the CIOv adapter is designed to work with the CFFh adapter to support this combination workload.

Figure 1. Ethernet Expansion Card (CIOv)

[A photograph of the Ethernet Expansion Card (CIOv) for BladeCenter. The card is green with various components, including a Broadcom chip labeled 'BCM5709S', and two RJ45 Ethernet ports.]

Part Number Information

Table 1. Ordering Part Number and Feature Code

DescriptionPart NumberFeature Code
Ethernet Expansion Card (CIOv) for BladeCenter
* Withdrawn from marketing
44W4475*1039

This part number includes the following items:

Features

The expansion card has the following features:

Operating Environment

The expansion card is supported in this environment:

Supported Servers and I/O Modules

Table 2. Supported Servers

HS12HS21HS21 XMHS22LS21LS22LS41LS42JS23JS43QS22PN41
Ethernet Expansion Card (CIOv)44W4475NNNYNNNNNNNNNN

See ServerProven for the latest information on the expansion cards supported by each blade server type: http://www.lenovo.com/us/en/serverproven/.

CIOv expansion cards are installed in the CIOv slot in supported servers such as the HS22, as shown in green in Figure 2.

Figure 2. Location of the CIOv slot in the BladeCenter HS22

[A diagram illustrating the internal layout of an IBM BladeCenter HS22 server. It highlights the location of the CIOv expansion card in the CIOv slot (colored green) and a CFFh expansion card for further expansion (colored red).]

The Ethernet Expansion Card (CIOv) requires that a supported I/O module is installed in bay 3 and bay 4 of the chassis that the cards and servers are installed in. The supported I/O modules are:

Popular Configurations

Adding Two Extra Ethernet Ports Per Blade Server

Most often, the Ethernet Expansion Card (CIOv) is used to expand the number of Ethernet ports per blade to increase network bandwidth. This is shown in Figure 3.

Figure 3. The Ethernet Expansion Card (CIOv) provides two extra Ethernet ports per blade server

[A diagram showing a typical configuration for expanding Ethernet ports on a BladeCenter server. It depicts an IBM BladeCenter server connected to an IBM BladeCenter chassis, with the Ethernet Expansion Card (CIOv) installed in the server to provide additional Ethernet ports.]

Table 3. Components Used When Connecting the Ethernet Expansion Card (CIOv) to External Ethernet Network

Diagram referencePart number / Machine typeDescriptionQuantity
1VariesBladeCenter HS22 or other supported server1 to 14
244W4475Ethernet Expansion Card (CIOv)1 per server
3VariesBladeCenter E, BladeCenter H, or BladeCenter S*1
4VariesAny Ethernet-compatible switch module1 or 2

*Note: The expansion card can be installed in servers in the BladeCenter S (8886). However, by doing so you will lose the ability to connect to the BladeCenter S Disk Storage Modules (DSMs). The Ethernet expansion card will go in the place of the SAS expansion card needed to connected to the DSMs. Instead, use the 2/4 Port Ethernet Expansion Card (CFFh), part number 44W4479.

iSCSI SAN Storage Solution

In addition, this card can be used to connect to external iSCSI-based entry-level SAN, as shown in Figure 4.

Figure 4. BladeCenter Connected to an External IBM System Storage DS3300 Storage Solution

[A diagram illustrating a BladeCenter server connected to an external IBM System Storage DS3300 storage solution for iSCSI SAN storage. The diagram shows the server, chassis, and storage system with numbered components indicating the connection flow.]

Table 4. Components Used When Connecting the Ethernet Expansion Card (CIOv) to External iSCSI Disk Storage

Diagram referencePart number / Machine typeDescriptionQuantity
1VariesBladeCenter HS22 or other supported server1 to 14
244W4475Ethernet Expansion Card (CIOv)1 per server
3VariesBladeCenter E, BladeCenter H, or BladeCenter S*1
4VariesAny Ethernet-compatible switch module1 or 2
51726-31X or 1726-32XIBM System Storage DS3300 (Single or Dual Controller)1
61727Optional IBM System Storage EXP3000 (Single or Dual ESM)1 to 3
739R6536DS3000 Partition Expansion License1

*Note: The expansion card can be installed in servers in the BladeCenter S (8886). However, by doing so you will lose the ability to connect to the BladeCenter S Disk Storage Modules (DSMs). The Ethernet expansion card will go in the place of the SAS expansion card needed to connected to the DSMs. Instead, use the 2/4 Port Ethernet Expansion Card (CFFh), part number 44W4479.

This configuration will also require cabling between the chassis and the storage server and between the storage server and expansion units. (The cable part numbers are not listed in Table 4.)

Supported Operating Systems

The following operating systems support the expansion card:

See ServerProven for the latest information on the specific versions and service packs supported: http://www.lenovo.com/us/en/serverproven/. Select the blade server and then select the expansion card to see the supported operating systems.

Related Publications

For more information refer to these documents:

Related Product Families

Product families related to this document are the following:

Notices

Lenovo may not offer the products, services, or features discussed in this document in all countries. Consult your local Lenovo representative for information on the products and services currently available in your area. Any reference to a Lenovo product, program, or service is not intended to state or imply that only that Lenovo product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any Lenovo intellectual property right may be used instead. However, it is the user's responsibility to evaluate and verify the operation of any other product, program, or service. Lenovo may have patents or pending patent applications covering subject matter described in this document. The furnishing of this document does not give you any license to these patents. You can send license inquiries, in writing, to:

Lenovo (United States), Inc.
8001 Development Drive
Morrisville, NC 27560
U.S.A.
Attention: Lenovo Director of Licensing

LENOVO PROVIDES THIS PUBLICATION "AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some jurisdictions do not allow disclaimer of express or implied warranties in certain transactions, therefore, this statement may not apply to you.

This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. Lenovo may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice.

The products described in this document are not intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. The information contained in this document does not affect or change Lenovo product specifications or warranties. Nothing in this document shall operate as an express or implied license or indemnity under the intellectual property rights of Lenovo or third parties. All information contained in this document was obtained in specific environments and is presented as an illustration. The result obtained in other operating environments may vary. Lenovo may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you.

Any references in this publication to non-Lenovo Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials for this Lenovo product, and use of those Web sites is at your own risk. Any performance data contained herein was determined in a controlled environment. Therefore, the result obtained in other operating environments may vary significantly. Some measurements may have been made on development-level systems and there is no guarantee that these measurements will be the same on generally available systems. Furthermore, some measurements may have been estimated through extrapolation. Actual results may vary. Users of this document should verify the applicable data for their specific environment.

© Copyright Lenovo 2022. All rights reserved.

This document, TIPS0697, was created or updated on May 29, 2009.

Send us your comments in one of the following ways:

This document is available online at https://lenovopress.lenovo.com/TIPS0697.

Trademarks

Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.

The following terms are trademarks of Lenovo in the United States, other countries, or both:

The following terms are trademarks of other companies:

Models: Ethernet Expansion Card, CIOv, Ethernet Expansion Card CIOv for BladeCenter, Ethernet Expansion Card CIOv, Ethernet Expansion Card for BladeCenter

File Info : application/pdf, 8 Pages, 253.43KB

PDF preview unavailable. Download the PDF instead.

tips0697

References

wkhtmltopdf 0.12.4-dev-4fa8338 Qt 4.8.7

Related Documents

Preview QLogic 4Gb Fibre Channel Expansion Card (CIOv) for BladeCenter - Product Guide
Product guide for the QLogic 4Gb Fibre Channel Expansion Card (CIOv) for Lenovo BladeCenter, detailing its features, specifications, supported servers, configurations, and operating environments. This product is withdrawn from marketing.
Preview Lenovo 2-Port 40 Gb InfiniBand Expansion Card (CFFh) for BladeCenter Product Guide
Product guide for the withdrawn Lenovo 2-Port 40 Gb InfiniBand Expansion Card (CFFh) for BladeCenter, detailing its features, specifications, supported environments, servers, I/O modules, and configurations. Based on Mellanox ConnectX IB technology, it offers dual 40 Gbps InfiniBand ports for high-performance computing.
Preview IBM Storwize V3700 for Lenovo Product Guide
This product guide provides a comprehensive overview of the IBM Storwize V3700 Storage System for Lenovo (Machine Type 6099), detailing its features, specifications, components, and connectivity options. It covers scalable storage solutions for organizations of all sizes, emphasizing ease of use, efficiency, and flexibility.
Preview Lenovo BladeCenter 1/10Gb Uplink Ethernet Switch Module Product Guide (Withdrawn)
A comprehensive product guide for the withdrawn Lenovo BladeCenter 1/10Gb Uplink Ethernet Switch Module, detailing its features, specifications, part numbers, benefits, supported configurations, and network cabling requirements for data center environments.
Preview Chelsio 10GbE Adapters for IBM System Cluster 1350 and IBM iDataPlex: Product Guide
This product guide provides detailed information on Chelsio 10GbE adapters for IBM System Cluster 1350 and IBM iDataPlex. It covers adapter features, specifications, part numbers, supported servers and operating systems, and related resources. The adapters offer high performance, low latency, and protocol offload capabilities for demanding cluster environments.
Preview Lenovo Storage E1012 and E1024 Disk Expansion Enclosures Product Guide (Withdrawn)
Product guide for Lenovo Storage E1012 and E1024 Disk Expansion Enclosures, detailing their features, system specifications, connectivity, drive options, power cables, and compatibility. Note: These products are withdrawn and no longer available for ordering.
Preview Emulex 16Gb Gen 5 Fibre Channel Adapters Product Guide
Product guide for Emulex 16Gb Gen 5 Fibre Channel (FC) Host Bus Adapters (HBAs), detailing features, technical specifications, server compatibility across various Intel Xeon processors, operating system support, physical dimensions, warranty, and agency approvals. Designed for high-performance storage networking in enterprise environments.
Preview Lenovo ServeRAID-BR10i SAS/SATA Controller (Withdrawn) Product Guide
Product guide for the withdrawn Lenovo ServeRAID-BR10i SAS/SATA Controller, detailing its specifications, operating environment, warranty, and supported IBM System x servers.