Product Structure Diagram

The Nuliie YM-8806 Wearable Breast Pump consists of the following parts:

1. Dust cover
2. 24mm Flange insert
3. 20mm Flange insert
4. 17mm Flange insert
5. 14mm Flange insert
6. Breast shield (27mm Flange)
7. Connector body
8. Suction bowl
9. Valve
10. Milk collector
11. Pump motor
12. USB charging cable

Button Function and LED Display Description

The pump features several buttons and an LED display for operation:

A. Power Button: Press and hold for 2 seconds to turn the machine on or off. A single press initiates a pause. The pump automatically shuts down after 5 minutes of inactivity or 30 minutes of continuous operation for energy efficiency.
B. Mode Switch Button: Short press to cycle through Stimulation, Expression, Bionic, and Auto modes.
C. Level-Up Button: Increases suction level from 1 to 12.
D. Level Down Button: Decreases suction level from 12 to 1.
E. Stimulation Mode: Stimulates the mammary gland for lactation with 12 levels, featuring rapid pumping frequency and gentle suction.
F. Expression Mode: Suitable for efficient and rapid milk collection, with 12 levels offering slow pumping frequency and powerful suction.
G. Bionic Mode: Combines stimulation and expression modes for a more immersive and natural pumping experience, featuring 12 levels.
H. Automatic Mode: Operates expression and bionic modes simultaneously for a comprehensive pumping experience.
I. Level/Running Time: Displays the current suction level and running time.
J. Battery Level: Indicates battery status with three levels for easy monitoring.
K. Unit for measuring running time.

Battery Charging and Status

Battery Charging Procedure

The product has a built-in lithium battery. When the LED power display shows one red bar and flashes, the battery is low and needs recharging.

  1. Open the silicone plug on the side of the motor to access the charging port.
  2. Connect the DC Type-C port of the USB charging cable to the charging port. Then, plug the other end of the USB connector into a DC5V/1A adapter, power bank, or a socket with a USB port.

Note: Do not use the pump while charging. The display interface will only indicate the power level while charging.

Battery Status

The LED display indicates the battery status:

LED DisplayBattery Status
Full barsFully charged
Partial barsMedium battery level (41%-70%)
One flashing barLow on battery
Flashing barWill power off soon
Flashing barCharging

Assembly Procedure

Follow these steps for proper assembly:

  1. Thoroughly wash your hands before assembling the cleaned components.
  2. Insert the silicone flange into the breast shield and then the assembled piece into the connector body. Press the edges with both hands to ensure a tight bond.
  3. Insert the suction bowl tightly inside the connector body from the top, then attach the valve to the bottom of the connector body.
  4. Install the assembled breast shield and connector body onto the milk collector and align the positioning line to ensure a firm and correct bonding.
  5. Install the pump motor onto the milk collector, aligning the notch under the motor with the milk collector. Assemble it downward to fit and ensure it is appropriately affixed.
  6. Attach the dust cover to the milk collector to complete the assembly.

Usage Instructions

Before Pumping

  1. Ensure the proper assembly of the pump by following the instructions above.
  2. Warm the breasts for five minutes using a heated towel or a hot and cold compress to stimulate mammary gland growth.

Pumping Process

  1. Place the breast shield over your breast without any gaps and insert the nipple inside the flange. Keep your nipple upright and use your other hand to hold the breast, ensuring that no air enters. Avoid moving the device or your breasts during pumping.
  2. Turn on the breast pump by long pressing the power button `▶️` for two seconds. Short press the power button `⏸️` to pause pumping.
  3. After turning on, the pump initiates the default stimulation mode. Press the `( )` button to toggle between modes: stimulation, expression, bionic, and auto mode.
  4. Each mode features 12 levels of suction. Increase suction by pressing the `➕` button and decrease it using the `➖` button to adjust to your comfort level.

After Pumping

  1. Turn off the breast pump by long pressing the power button for two seconds.
  2. Carefully lift the breast pump away from your breast, maintaining an upright position. Afterwards, detach the motor from the milk collector.
  3. To transfer the milk to the storage bottle, pour it through the outlet port. You can rotate the milk collector to extract any remaining milk.

Cleaning Washable Accessories

The washable accessories include the dust cover, flange insert, breast shield, connector body, suction bowl, valve, and milk collector.

Washing Process

  1. Take apart all washable accessories from the breast pump, ensuring thorough disassembly.
  2. Rinse each washable accessory under running water to remove any visible milk residue.
  3. Submerge the accessories in warm, soapy water for 5 minutes to clean and disinfect them effectively.
  4. Use a soft brush to scrub the components, paying attention to hard-to-reach areas gently.
  5. Rinse all components thoroughly to eliminate any soap residue.

Disinfect

  1. Submerge the washable accessories in boiling water and let them simmer for 5 minutes. Ensure the temperature does not exceed 100°C (212°F).
  2. Allow the washed accessories to air dry entirely before reassembling or storing them.
  3. Alternatively, you can use a dishwasher or steam sterilization method to clean the accessories.

Tip: Sterilizing the breast pump accessories using a microwave oven or ultraviolet disinfection cabinet is not recommended, as it may reduce their durability.

Troubleshooting

No.ProblemSolutions
1Inadequate suction
  • Check that all accessories are securely connected and ensure there is no air leakage.
  • Reassemble the accessories following the provided assembly instructions.
  • Verify that the valve outlet can open and close normally.
  • Ensure that the breast shield fits the breast perfectly.
  • Use the highest suction level.
2Slow pumping
  • The pumping speed may vary depending on your breast structure and mood. Regular pumping can improve pumping efficiency.
  • Consider warming your breast with a warm towel compress before pumping to boost milk production.
  • Start with the stimulation mode for 2 minutes, then switch to expression mode.
  • Adjust the suction level or massage your breast by hand to facilitate milk flow.
3Unable to pump due to swollen breasts
  • A breast obstruction may lead to reduced milk flow.
  • Perform breast massage:
    • Circular massage
    • Spiral massage
    • Shiatsu massage
  • Ensure relaxation and obtain sufficient rest.
4Painful during pumping
  • Ensure that you have chosen the correct size flange.
  • Reduce the suction level.
5The breast does not empty completely
  • It is usual for different pumping methods to occasionally leave some milk in the breasts due to differences in breast structure, pumping frequency, and intensity.
  • Consider using another suitable method to express any remaining milk after using the breast pump.
6Low noiseThe breast pump generates suction by inhaling and deflating the pump body, which may produce some noise. This product is designed to minimize noise, with the decibel level maintained within the standard range of approximately 45 to 55 dB.
7Milk leaking
  • Ensure all breast pump parts are assembled correctly, especially the assembled connector body with the milk collector. Align the positioning line to fit it into the milk collector properly.
  • Check for any damage or deformities in the parts, and if you find any, please replace them promptly.
8The breast pump does not respond and cannot be turned on
  • Ensure that the breast pump is fully charged before use.
  • If the issue persists, it may be due to water or milk flowing into the main motor of the pump. Always remove the pump motor before pouring breast milk, and avoid submerging it in water when cleaning to prevent any damage.
  • If problems persist and you suspect a motor malfunction, please get in touch with our 24/7 live chat or email us at support@nuliie.com for the best solution.

Cautions

  • Nuliie breast pump is designed for individual use only. Sharing it with multiple users can compromise their health and safety.
  • Do not use the breast pump while charging.
  • Keep the motor away from high temperatures and ignition sources to avoid the risk of combustion and explosion.
  • If you experience little or no breast milk expression or pain while expressing breast milk, please consult a medical professional.
  • Do not submerge the motor in water for cleaning or disinfection, and avoid using steam sterilizers for disinfection.
  • Please use a 5V adapter for charging. If the power adapter's output voltage exceeds 5V, the level indicator will show "E1," and the motor will activate over-voltage protection, preventing it from being charged.
  • During the usage and cleaning of the accessories, the parts undergo various temperature changes and exposure to chemical detergents. We recommend replacing the parts every 3 to 6 months, and if you notice any damage, please replace them promptly.

Compliance and Disposal

FCC Information

Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Correct Disposal of This Product

This marking `♻️` (Waste Electrical & Electronic Equipment) shown on the product or its literature indicates that it should not be disposed of with other household wastes at the end of its working life.

To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources. Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmentally safe recycling.

Business users should contact their supplier and check the terms and conditions of the purchase contract. This product should not be mixed with other commercial wastes for disposal.

Manufacturer and Representatives

Manufacturer: Guangdong Youmeng Electrical Technology Co., Ltd.

Address: One of Area A, Level 3, Building 2, No. 17, Keyuan 3rd Road, Xiaohuangpu Community, Ronggui Street, Shunde District, Foshan City, Guangdong Province, China.

European Representative (EC REP): UAB Qixiang Europe, Pranciškonų g. 6-46, LT-01133 Vilnius, Lithuania. Technical Information Center, Trakehner Str. 7-9, 60487 Frankfurt am Main, Germany. Email: qixiang.europe@gmail.com. Phone: +49 6976 895074.

United Kingdom Representative (UK REP): CET Product Service Ltd, Beacon House Stokenchurch Business Park, Ibstone Rd, Stokenchurch, High Wycombe HP14 3FE UK. Email: info.cetservice@gmail.com. Phone: +44 7419325266.

Scan the QR Code for Videos and FAQs.

Models: YM-8806, YM-8806 Wearable Breast Pump, Wearable Breast Pump, Breast Pump, Pump

File Info : application/pdf, 12 Pages, 1.19MB

PDF preview unavailable. Download the PDF instead.

YM8806-User-Manual

References

Adobe PDF Library 17.0 Adobe InDesign 19.0 (Windows)

Related Documents

Preview Nuliie YM-8806 Wearable Breast Pump User Manual - Guide and Instructions
Comprehensive user manual for the Nuliie YM-8806 Wearable Breast Pump. Learn about assembly, operation modes, charging, cleaning, and troubleshooting for optimal use.
Preview Nuliie YM-8806 Wearable Breast Pump User Manual
Comprehensive user manual for the Nuliie YM-8806 Wearable Breast Pump, covering product structure, button functions, LED display, battery charging, assembly, pumping process, cleaning, and troubleshooting. Available in English, German, Spanish, French, and Italian.
Preview Nuliie YM-8806 Wearable Breast Pump User Manual
Comprehensive user manual for the Nuliie YM-8806 Wearable Breast Pump, covering product structure, button functions, LED display, battery charging, assembly, operation instructions, cleaning, and troubleshooting.
Preview Nuliie YM-8806 Wearable Breast Pump User Manual
User manual for the Nuliie YM-8806 Wearable Breast Pump. Provides detailed instructions on assembly, operation, charging, cleaning, troubleshooting, and safety guidelines for optimal use.
Preview Nuliie Wearable Breast Pump S32 User Manual
Comprehensive user manual for the Nuliie Wearable Breast Pump S32, covering assembly, usage, cleaning, storage, and troubleshooting. Learn how to effectively and comfortably use your Nuliie breast pump.
Preview Nuliie S32 Wearable Breast Pump User Manual
Comprehensive user manual for the Nuliie S32 Wearable Breast Pump, detailing product structure, button functions, LED display, battery charging, assembly, usage instructions, cleaning, and troubleshooting.
Preview Nuliie S32 Wearable Breast Pump User Manual
Comprehensive user manual for the Nuliie S32 Wearable Breast Pump, detailing product structure, button functions, LED display, battery charging, assembly, usage instructions, cleaning, and troubleshooting.
Preview Nuliie S32 Wearable Breast Pump User Manual
Comprehensive user manual for the Nuliie S32 wearable breast pump, detailing product structure, button functions, battery charging, assembly, usage instructions, cleaning, and troubleshooting.