User Manual for Chiyang Scent models including: 2A3DS-A305, 2A3DSA305, A305S, A305S Scent Diffuser Machine, Scent Diffuser Machine, Diffuser Machine
Guangzhou Chiyang Scent Technology Co., LTD. A305 2A3DS-A305 2A3DSA305 a305
50301-00001B1.0CYG-00117-B10-A305 APP instructions Where can I download this APP: Please search "scent marketing" in Google play or App store. Add device AAA AAA AAA Input password Name: AAA Label: AAAAAA Amend device name Remarks: location Delete working period Add working period Time switch (PS: There are 5 working periods available to be set.) Time setting Date Mon TUES WED THUR FRI SAT SUN ON/OFF Local time Diffusing display Current grade Power on/off Connect power supply, power on with a sound "beep", and the screen displays initial time and current grade. The screen will be off when disconnect the power. Fan on/off Touch button (3s) to turn on fan, touch button (3s) to turn off fan. Mon Auto-lock and un-lock TUES WED Button will be locked automatically if there is no any THUR FRI further manual manipulation in 60s; Touch SET SAT (about 5s) comes out with sound "beep" and screen SUN lights on to unlock machine. Local time setting Touch SET button (about 3s) till a sound "beep" comes out for day setting; touchorto adjust the day; touch ENT button for local time setting, touch orto adjust the time (Figure 1) (1) Mon TUES WED THUR FRI SAT SUN Concentration grade setting There are 20 grades available. Touchto increase (2) grade, touch to decrease grade(Figure 2). Amend password AAAA AAAA AAAA If you forget the password, please press the reset button to restore the factory settings. The factory settings password is 8888. Slide up and down to adjust Select the day Select grade Work time period setting There are 5 working periods available to be set every day Mon (Figure 3). TUES WED Touch SET button to set working period (ON1) , touch THUR FRI or to choose working period (1-5); touch ENT button SAT for the working period switch, touch or to choose ON SUN or OFF, touch ENT button again to move to the operation time, touch orto adjust number. Touch ENT again for grade. Next touch ENT to choose the (3) day (MON), touch button to turn on the working period (ON1) (Figure4), touch button to turn off the working Mon period (OFF1) (Figure5). TUES WED Touch ENT to move to the next day and repeat the steps THUR FRI for TUES to SUN. SAT Once finish, touch SET to confirm and exit, Repeat the SUN same setting steps of ON1 for ON2, ON3 ON4 and ON5. PS:Grade display with "-Cu-" is for customized grade set by APP only(Figure6). (4) Machine doesn't work when the start working period is as same as stop working time Mon TUES Working time period 00:00 - 00:00 00:00 - 00:00 00:00 - 00:00 00:00 - 00:00 00:00 - 00:00 WED THUR FRI SAT SUN Mon ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF Thues ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF Wed ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF (5) Thur Fri Sat Sun ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF Mon TUES WED THUR FRI SAT SUN (PS: The first working period is factory defaults with start working time 07:00 and stop working time 19:00, Grade1, the rest are all with 00:00.) (6) PRODUCT MANUAL SCENT MARKETING A305S/M/L Concentration and Consumption Grade Consumption(ml/h) work(s) intervals(s) A305S-BLE A305M-BLE A305L-BLE G1 15s 300s 0.10 0.1 0.2 G2 15s 150s 0.14 0.2 0.3 G3 20s 120s 0.18 0.3 0.5 G4 20s 85s 0.22 0.4 0.6 G5 25s 80s 0.26 0.5 0.8 G6 30s 75s 0.30 0.6 0.9 G7 30s 60s 0.34 0.7 1.0 G8 30s 50s 0.38 0.8 1.2 G9 30s 40s 0.45 0.9 1.3 G10 30s 33s 0.50 1.0 1.5 G11 33s 30s 0.55 1.1 1.8 G12 40s 30s 0.60 1.2 2.0 G13 50s 30s 0.65 1.3 2.3 G14 60s 30s 0.70 1.4 2.5 G15 75s 30s 0.75 1.5 2.8 G16 80s 25s 0.80 1.6 3.0 G17 85s 20s 0.85 1.7 3.3 G18 120s 20s 0.90 1.8 3.5 G19 150s 15s 0.95 1.9 3.8 G20 300s 15s 1.00 2.0 4.0 Cu 5-500s 5-500s Up grade Down grade Notice:1. Above date is base on test trial. 2.Consumption data is for reference only. Different fragrance may be coming with different consumption. 12 Specification Product Name Model Coverage Dimension Bottle Weight Power Voltage : Aroma diffuser : A305S/ A305M/ A305L : 200m2/600m3 400m2/1200m3 : 295*222*112.5mm : 850ml : 2.05kg 2.45kg 2.60kg : 6W /6W / 9W : DC12V 800m2/2400m3 Overview Atomized connector Lock Control Atomized Mounting Mounting panel head Bottle nail bracket DC connector Instruction Plug Bottle Bottle cap PU tube Manual Atomized nozzle Key connector Mounting bracket Sealing tape Screw Usage of sealing tape: 1.Before replacing atomizing core, wrap sealing tape around atomized core thread about 3-5 turns to avoid air leakage; 2.Before connecting atomized connector, wrap sealing tape around atomized connector thread about 3-5 turns to avoid air leakage. 1.Open the door by key 2.Unscrew the atomized nozzle, take out the bottle 3.Twist the bottle and fill essential oil 4.Put atomized head to bottle and screw the atomized nozzle 5.Finish time setting and lock machine ! Caution Shall not modify, disassemble or repair the machine arbitrarily. Any failure happens, please contact technician in time. Shall not damage the power cord, force to bend, yank, heavy load, clip or reprocess. - Shall not use damaged plug or unmatched with the socket; - Shall not wet the machine or the plug; - Shall not use overloaded power socket, wire or broken plug. Shall not touch the wire or product shell when thundering or/and lightening. Shall not disassemble the machine when it is under operating. Warning 1.Please keep the machine vertical. Tilt or lie flatly may cause oil over flow. Themachine efficiency may be affected. 2.Shall not modify, disassemble or repair the machine if you are not a technician. If any failure happens to the machine, please contact our technical personnel. 3.The machine is stop during off work time period, even the Atomization display is on 4.The button is invalid and no display on screen when machine locked 5.If the display is cluttered, freezes or other problem, please restart machine to reset to defaults(Method: Press ENT button and hold on about 5 seconds till hear a sound "beep") Installation The method of using expansion bolts Drill the wall, insert the expansion tube into the hole, put the screw into the expansion tube and tighten it Installation steps Direction Idea for Hotels, Conference rooms, Malls, Exhibition halls, Major retailers, Bars, SPAs, Business places or anywhere you wanto a fragrance experience. Troubleshooting Before asking to have the machine repaired, please try to diagnose the problem first following to below instructions. Breakdown Solution Does not diffuse -Check whether the mode you choose is correct or not. -Check if the machine is during "Non-Working period" -Air pump may be damaged, change a new one. -Check whether the tube is loose or not Weak diffuse Oil leaking Oil sprinkle Abnormal noise -The atomizing core is blocked, clean by alcohol or change a new component. -Check whether the gasket is damange/loose or not. -Check whether the tube is loose or not -Check whether the bottle is loose or not -The gasket in the atomized head is damaged or -The atomized head is damaged, change a new one -The machine is tilled or lie down, keep the machine -The air pump is loose, retighten the pump -The air pump is damaged, change a new one. 1.Aim at the position of the mounting bracket, then drill the hole in the wall and insert the expansion bolts into the hole in the wall; 2.Install the mounting bracket on the wall with screws, and finally hang the machine on the mounting bracket. 22 297*210mm 128g FCC Warning This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE 1: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. NOTE 2: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. The device has been evaluated to meet general RF exposure requirement. 33 CE Caution Use the product in the environment with the temperature between -10 and 50; Otherwise, it may damage your phone. I t can be operated under 2000m. For the following equipment: Product Name: Aroma diffuser Model: A305 Guangzhou Chiyang Scent Technology Co., LTD. hereby declares that this [ Name: Aroma diffuser, Model: A305] is in compliance with the essential requirements and other relevant provisions of Directive 2014/ 53/ EU. This product can be used across EU member states. CAUTI ON: RI SK OF EXPLOSI ON I F BATTERY I S REPLACED BY AN I NCORRECT TYPE. DI SPOSE OF USED BATTERI ES ACCORDI NG TO THE I NSTRUCTI ONS. Do not use other unauthorized chargers power supply for charging. Do not use the product in environment below -10 or above 50 for charging. Bluetooth Support Standard: Frequency Range: Max. RF Output Power: Type of Modulation: Data Rate: Quantity of Channels 802.15.1 2402-2480MHz 1.87dBm (EIRP) GFSK 1Mbps 40Corel PDF Engine Version 22.0.0.412