Banner K50 Pick-to-Light Series
Indicador independiente para operaciones de recolección de contenedores
Features
- Robust, cost-effective, and easy-to-install solutions for error-proofing and part verification applications.
- Compact, self-contained devices require no controller.
- Illuminated dome provides a highly visible green work light; some models also feature a red light for alternating operation.
- Models available with touch button and passive actuator.
- Fully encapsulated IP67 housing: suitable for use in environments rated for IP69K per ISO 20653, depending on installation.
- Immune to ambient light and EMI/RFI interference.
- AS-i module compatible.
- Operates on 12 V DC to 30 V DC.
WARNING:
- Do not use this device for personnel protection.
- Failure to comply with this warning could result in serious injury or death.
- This device does not include the redundant, self-monitoring circuitry required for use in personnel safety applications. A device failure can cause an energized (on) or de-energized (off) output condition.
Standard Models - Single Color
The work light is on at all times while the trigger input is active. Hand presence (or touch button press) activates the output.
Model | Sensing Mode / LED | Housing | Range | Connection (1) | Output (2) | Work Light |
---|---|---|---|---|---|---|
K50APLPGXDQ | Polarized retroreflective, visible red, 680 nm | 50 mm dome, 30 mm polycarbonate bracket | 2 m (6 ft) | Integral M12 quick-disconnect male connector, 4-pin | PNP, normally open (N.O.) | Green |
K50RPLPGXDQ | PNP, normally closed (N.C.) | |||||
K50APFF50GXDQ | Fixed field infrared, 880 nm | 50 mm cutoff | Integral M12 quick-disconnect male connector, 4-pin | PNP, normally open (N.O.) | Green | |
K50ANFF50GXDQ | NPN, N.O. | |||||
K50APFF100GXDQ | Fixed field infrared, 880 nm | 100 mm cutoff | Integral M12 quick-disconnect male connector, 4-pin | PNP, normally open (N.O.) | Green |
(1) Models with integral M12 quick-disconnect connector are included. To order the 2 m (6.5 ft) PVC-jacketed cable model, omit the "Q" suffix from the model number. For example, K50APLPGXD. To order the 9 m (30 ft) PVC-jacketed cable model, add the "W/30" suffix to the cabled model number. For example, K50APLPGXD W/30. To order the 150 mm (6 in) PVC-jacketed cable model with an M12 4-pin quick-disconnect connector, change the "Q" suffix to "QP" in the model number. For example, K50APLPGXDQP. Models with quick-disconnect (QD) connectors require a mating connector cable.
(2) N.O. = Normally Open; N.C. = Normally Closed
Specialized Series C: Two-Color Models, 12 V DC to 30 V DC
- The work light is green while the trigger input is active (unless a hand is present). Hand presence (or touch button press) activates the output and overrides the work light (turns red) to visually verify that action has been detected.
- Retro-reflective models: For simplified alignment, the sensor emits a red signal when the retro-reflective target is misaligned.
Model | Sensing Mode / LED | Range | Connection (1) | Output (2) | Work Light |
---|---|---|---|---|---|
K50RPLPGRCQ | Polarized retroreflective, visible red, 680 nm | 2 m (6 ft) | Integral M12 quick-disconnect male connector, 4-pin | PNP, normally closed (N.C.) | Green (Red) |
K50APFF50GRCQ | Fixed field infrared, 880 nm | 50 mm cutoff | PNP, normally open (N.O.) | ||
K50ANFF50GRCQ | NPN, N.O. | ||||
K50APFF100GRCQ | Fixed field infrared, 880 nm | 100 mm cutoff | Integral M12 quick-disconnect male connector, 4-pin | PNP, normally open (N.O.) | Green (Red) |
K50ANFF100GRCQ | NPN, N.O. | ||||
K50APPBGRCQ | Touch button | Integral M12 quick-disconnect male connector, 4-pin | PNP, normally open (N.O.) | Green (Red) |
Specialized Series E: Two-Color Models
- The work light is green at all times while the trigger input is active. Hand presence (or touch button press) activates the output.
- Hand presence (or button press) while the trigger input is inactive causes the unit to illuminate red, to visually verify that the sensor is functioning correctly.
Model | Sensing Mode / LED | Range | Connection (1) | Output (2) | Work Light |
---|---|---|---|---|---|
K50RPLPGREQ | Polarized retroreflective, visible red, 680 nm | 2 m (6 ft) | Integral M12 quick-disconnect male connector, 4-pin | PNP, normally closed (N.C.) | Green (Red) |
K50RNLPGREQ | NPN, N.C. | ||||
K50APFF50GREQ | Fixed field infrared, 880 nm | 50 mm cutoff | PNP, normally open (N.O.) | ||
K50APFF100GREQ | Fixed field infrared, 880 nm | 100 mm cutoff | Integral M12 quick-disconnect male connector, 4-pin | PNP, normally open (N.O.) | Green (Red) |
K50ANFF100GREQ | NPN, N.O. | ||||
K50APPBGREQ | Touch button | Integral M12 quick-disconnect male connector, 4-pin | PNP, normally open (N.O.) | Green (Red) | |
K50ANPBGREQ | Touch button | Integral M12 quick-disconnect male connector, 4-pin | NPN, N.O. | Green (Red) |
Installation
- For touch button models, mount the sensor at a height and location where the user or supervisor can easily see the indicator and comfortably press the button.
- For other models, mount the sensor where it is convenient for the user to interrupt the beam to reach for the required part. When multiple sensors are located very close together (e.g., to monitor multiple bins), mount all sensors in a similar sensing position (e.g., all mounted at the top of bins and looking down). This can reduce potential optical interference, where one sensor detects the beam of another sensor.
Wiring Diagrams
M12 quick-disconnect 4-pin male connector
NPN Models
Diagram showing wiring for NPN models with pin assignments: 1-Brown (+V DC), 2-White (Light function), 3-Blue (0V DC), 4-Black (Output).
PNP Models
Diagram showing wiring for PNP models with pin assignments: 1-Brown (+V DC), 2-White (Light function), 3-Blue (0V DC), 4-Black (Output).
Note: Wiring diagrams are shown. Quick-disconnect wiring diagrams are functionally identical.
Specifications
Power Supply Voltage and Current
- 12 V DC to 30 V DC
- < 75 mA max. current at 12 V DC (no load)
- < 40 mA max. current at 30 V DC (no load)
- AS-i compatible
Power Supply Protection Circuit
- Protected against reverse polarity and transient overvoltage (fast transients and surge).
Output Protection Circuit
- Protected against output short circuit, continuous overload, and false pulses during turn-on.
Output Response Time
- 3 milliseconds on and off.
Turn-on Output Delay Time
- 300 milliseconds.
Indicators
- The translucent dome provides an indicator light; the work light or detected pick light inhibits the other light, depending on the model.
- Work Light Indicator: Green
- Pick Detection Indicator: Red or unlit, depending on the model.
Environmental Protection Rating
- Fully encapsulated; IP67
- Models with integrated quick-disconnect connector: IP69K per ISO 20653 when used with IP69K-rated cables.
- Cabled models: IP69K per ISO 20653 when installed with conduit.
- NEMA/UL Type 4X, 13.
Operating Conditions
- -40 °C to +50 °C (-40 °F to +122 °F)
- 90% at +50 °C maximum relative humidity (non-condensing).
Certifications
- CE
- CULUS LISTED
Work Light Activation Input
- Input impedance: 8000 ohm
- PNP Input low < 1.5 V
- NPN Input high > 7 V
Output Configuration
- NPN or PNP, depending on the model.
Output Rating
- Maximum load: 150 mA
- Leakage current in the off state: < 10 μA at 30 V DC
- Saturation voltage in the on state: < 2 V DC at 10 mA, < 2.5 V DC at 150 mA.
Material
- Housing: Polycarbonate
- Translucent dome: Polycarbonate
- Touch button: Thermoplastic
- Lens: Polycarbonate or acrylic.
Connections
- Integral M12 4-pin quick-disconnect male connector, 2 m (6.5 ft) PVC-jacketed cable with 4 unterminated wires, or 150 mm (6 in) PVC-jacketed cable with M12 4-pin quick-disconnect male connector, depending on the model.
Ambient Light Immunity
- Up to 5,000 lux.
EMI-RFI Immunity
- Immune to EMI and RFI noise sources, per IEC 947-5-2.
Overcurrent Protection Required
WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations.
Overcurrent protection must be provided as specified in the final application product table. Overcurrent protection may be provided by an external fuse or by the current-limiting feature of a Class 2 power supply. Power supply wiring conductors < 24 AWG should not be spliced together.
For additional product support, visit www.bannerengineering.com.
Power Supply Wiring (AWG) | Required Overcurrent Protection (A) | Power Supply Wiring (AWG) | Required Overcurrent Protection (A) |
---|---|---|---|
20 | 5.0 | 26 | 1.0 |
22 | 3.0 | 28 | 0.8 |
24 | 1.0 | 30 | 0.5 |
FCC Part 15 Class B for Unintentional Radiators
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
(Part 15.21) Any changes or modifications not expressly approved by the manufacturer could void the user's authority to operate the equipment.
Industry Canada ICES-003(B)
This device complies with CAN ICES-3 (B)/NMB-3(B). Operation is subject to the following two conditions: 1) This device may not cause harmful interference; and 2) This device must accept any interference received, including interference that may cause undesired operation.
Dimensions
All measurements are in millimeters (inches) unless otherwise indicated. Supplied measurements are subject to change.
*For touch button models, this dimension is 44.2 mm (1.74 in).
Accessories
Connector Cables
M12 female 4-pin single-ended connector cables
Model | Length | Style | Dimensions | Pin Assignment (Female) |
---|---|---|---|---|
MQDC-406 | 2 m (6.56 ft) | Straight | Diagram showing M12 connector dimensions: Ø5.2 mm, M12 x 1, Ø14.5 mm. | 1-Brown, 2-White, 3-Blue, 4-Black, 5-No use. |
MQDC-415 | 5 m (16.4 ft) | |||
MQDC-430 | 9 m (29.5 ft) | |||
MQDC-450 | 15 m (49.2 ft) | |||
MQDC-406RA | 2 m (6.56 ft) | Right Angle | Diagram showing M12 right angle connector dimensions: Ø5.2 mm, M12 x 1, Ø14.5 mm. Also shows depth of 58 mm and 7 mm. | 1-Brown, 2-White, 3-Blue, 4-Black, 5-No use. |
MQDC-415RA | 5 m (16.4 ft) | |||
MQDC-430RA | 9 m (29.5 ft) | |||
MQDC-450RA | 15 m (49.2 ft) |
Mounting Brackets
SMB30A
- Right-angle bracket with curved slot for versatile orientation.
- Clearance for M6 mounting accessories (1/2 in).
- 30 mm sensor mounting hole.
- 12-gauge stainless steel.
- Dimensions: A to B hole center distance: 40 mm. Hole size: A = Ø 6.3, B = 27.1 x 6.3, C = Ø 30.5.
SMB30FA
- Swivel bracket with tilt and slide movement for precise adjustment.
- 30 mm sensor mounting hole.
- 304 stainless steel, 12-gauge.
- Easy sensor mounting in extruded rail T-slot.
- Bolt available in metric and inch sizes. Bolt thread: SMB30FA, A = 3/8-16 x 2 in; SMB30FAM10, A = M10-1.5 x 50. Hole size: B = Ø 30.1.
SMB30FVK
- V-clamp, flat bracket, and fasteners for mounting to pipe or extensions.
- Clamp accepts 28 mm diameter tubing or 1-inch square extrusions.
- 30 mm hole for sensor mounting. Hole size: A = Ø 31.
SMB30RAVK
- V-clamp, right-angle bracket, and fasteners for mounting sensors to pipe or extrusions.
- Clamp accepts 28 mm diameter tubing or 1-inch square extrusions.
- 30 mm hole for sensor mounting. Hole size: A = Ø 30.5.
Limited Warranty of Banner Engineering Corp.
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year from the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any of its products which, at the time of its return to the factory, has been found to be defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the application or installation of Banner product in an improper manner.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES, WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING FROM COURSE OF PERFORMANCE, COURSE OF DEALING, OR TRADE USAGE.
This warranty is exclusive and is limited to the repair or, at Banner Engineering Corp.'s option, replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO THE PURCHASER OR ANY OTHER PERSON OR ENTITY FOR ANY ADDITIONAL COSTS, EXPENSES, LOSSES, LOST PROFITS, OR INCIDENTAL, CONSEQUENTIAL, OR SPECIAL DAMAGES ARISING OUT OF ANY DEFECT IN THE PRODUCT OR THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING FROM CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify, or improve the product design without incurring any obligations or liability for products previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product, or use of the product in personnel safety applications for which it was not designed, will void the warranty. Any modifications to this product without the prior express written approval of Banner Engineering Corp. will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. English language product specifications and information shall take precedence over information presented in any other language. For the most recent version of any documentation, please refer to: www.bannerengineering.com.
For patent information, see www.bannerengineering.com/patents.