Smart Lock
User Manual
H01A-TYAZ
Special Attention:
- Please keep any mechanical keys outdoors, in case of any emergencies requiring their use.
- Please promptly replace batteries after receiving low battery notification.
- Please carefully read this manual before installation, and keep it for future reference.
A line drawing depicts the front and back of the Smart Lock H01A-TYAZ, showing a digital keypad and handle.
1. Introduction
1.1. Lock structure
Diagram of lock structure with dimensions: Front Panel (72mm width, 140mm length), Back Panel (73mm width, 80mm length), Battery Cover, Electronic Locking Button, USB emergency power port, Lock Cylinder.
1.2. Packing List
NO | Name | Qty | NO. | Name | Qty |
1 | Front Panel | 1 | 10 | Mortise Screws:M5*10mm (For Aluminum Door) | 4 |
2 | Back Panel | 1 | 11 | Mortise Screws:M4*25mm (For Wooden Door) | 4 |
3 | Mortise | 1 | 12 | 60mm Square shaft | 1 |
4 | Card | 3 | 13 | 80mm Square shaft | 1 |
5 | Mechanical Key | 2 | 14 | M5*25mm Screw | 1 |
6 | Waterproof Rubber Plate | 2 | 15 | M5*40mm Screw | 1 |
7 | Screw Stubs:M5*35mm | 2 | 16 | M5*50mm Screw | 1 |
8 | Strike&Strike Box | 1+1 | 17 | U-Clip | 1 |
9 | Sliding Screws:M5*10mm | 1 | 18 | User Manual | 1 |
1.3. Specifications
Feature | Details | Feature | Details |
Suitable for Models | H01A-TYAZ | Doors Applicable | Aluminum door, Wooden door |
Materials | Aluminum alloy | Working Voltage | 6V/4x AA Batteries |
Lock Weight | 3KG | Door Thickness to Fit | 35-65mm |
Unlocking Way | Password, Card, Mechanical key | Data Capacity | Password: 10, Temporary password: 10, Card: 380 |
Color | Silver, Black | Working Temperature | -10℃-55℃ |
Low Wattage Alarm | Less than 4.8V | Working Humidity | 0-95% |
1.4. Networking mode:
- Touch to wake the screen.
- Long press the network configuration key for 5 seconds to enter the network configuration mode.
An image shows the inside of the battery compartment with four AA batteries installed. A label points to a 'Networking button'.
2. Installation
2.1. Turn the handle
Notice: Adjust the handle according to the direction you open the door.
Diagrams illustrating handle adjustment for front and back panels, showing screw loosening, handle positioning for left/right opening, and screw reinstallation.
2.2. Installation Diagram (For 5572)
Step 1 Install Mortise: Shows the mortise being inserted into the door edge.
Step 2 Install Sliding Screw Casing: Depicts installing the screw casing, noting its adjustable placement from 55mm to 100mm from the square shaft, depending on the door hole. An arrow indicates the correct orientation.
Step 3 Install Back Panel and link wire: Shows the back panel being attached and the wire connected.
Step 4 Install fixing screws: Illustrates securing the lock assembly with screws.
Step 5 Installation complete: Shows the fully installed lock.
3. Operation
3.1. Download
- The software (iOS version) can be downloaded from the app store.
- The Android version can be downloaded from the application store of Google Play.
- Scan the QR code to download.
Screenshots of the 'Smart Residence' app: Login screen and 'Create an account' screen.
3.2. Registration
- After entering the APP, click "Register" to create an account.
- Account authentication and password setting complete the registration.
- You can then log in to the system using your email or mobile number.
3.3. Account login
- After successful registration, you can log in to your account.
Screenshots show the app login interface, a 'Forgot Password' screen, and a keyboard layout for password entry.
3.4. Create sites and zones
- Upon first registration, create a site and areas (e.g., Living Room, Master Bedroom) for convenient device management.
Screenshots illustrate creating a new site with fields for Site Name and Location, and adding specific areas within the site.
3.5. Join the site
- You can join other users' sites in addition to creating your own.
- Invite site members after creating the site with other accounts.
- Upon invitation confirmation, the site and smart devices can be shared.
Screenshot shows the 'Join a site' interface.
3.6. Device
3.6.1. Add Device
- Select equipment category for installation (manual or auto-scan).
- Added devices can be accessed via the panel for function use and displayed in workbench widgets.
3.6.1.1. Add Gateway
- Tap 'Add Device' or the '+' icon on the Home page.
- Select 'Gateway', choose your Zigbee gateway type, and confirm 'Added successfully'.
Screenshots show the app interface for adding devices, selecting 'Gateway', and choosing between 'Wireless Gateway (Zigbee)', 'Wired Gateway (Zigbee)', and 'Wireless Gateway (BLE)'.
3.6.1.2. Add lock
- After adding the gateway, navigate to the gateway page and click 'Add sub device'.
- Select 'Door Lock' from the device types.
- Wake the door lock by touching the screen. Long press the network configuration key for 5 seconds to enter pairing mode. The app will show 'Under connecting, pls wait'.
- Upon successful pairing, the app will display 'Network join Succeed'.
Screenshots show the 'Zigbee Wireless Gate...' interface with 'Added devices', an option to 'Add subdevice', and the process of searching for and adding the 'H01A-TYAZ' door lock. It also shows device status like 'Guarding your home for 1 days' and options like 'Records', 'Unlock Ways', and 'Setting'.
3.7. Setting
3.7.1. Remote Open
- Enable 'Remote open setting' in the settings to unlock by pressing and holding the unlock button.
3.7.1.2. Free Verify
- When enabled, the door lock operates in normally open mode.
Screenshots of the app settings showing the 'Remote open setting' toggle and the 'Free Verify' option.
3.8. UnLock Ways
3.8.1. Manage Password
- Used for security verification on the door lock device side.
3.8.2. Emergency Password
- Use this password to unlock the lock in an emergency if other passwords are forgotten.
Screenshots of the 'UnLock' screen showing 'Admin Password', 'Manage Password' (effective), and 'Emergency Password' (effective). It also shows 'Guest PIN Code' with 'No temporary lock way'.
3.8.3 Add temporary password
- Enter a 6-digit password or generate one randomly.
- Set the effective and invalid time for the password.
- Enter a mobile phone number to receive the password.
- Optionally set the cycle time for password usage.
Screenshots for adding a temporary password, including input fields for password, effective/invalid times, password name, message (mobile number), and repeat/begin/end times for cycle usage.
3.9. Dashboard
3.9.1. Edit widget
- Access the workbench to add and assemble components for custom application scenarios.
- Widgets require corresponding equipment to be added first.
- Successfully added widgets display specific devices and functions in the workbench.
Screenshots show the 'Widgets for quick action' interface, 'Edit Widget' screen with options like 'Lock', 'Weather', 'Security mode', and 'Selected Devices' for the H01A-TYAZ lock.
3.9.2. Access
3.9.2.1. APP access (passenger)
- Add temporary access for users, select a time range, and grant equipment access.
- Users can then log in to the app to use the pass function.
Screenshots show setting up user access, including user name, email, account type (Administrator), access way, valid period, and device selection.
3.7.2.2. Password
- Add one-time or periodic passwords for users within specific time ranges.
Screenshots show selecting a device, setting a password with name, effective/expiration times, and repeat options. Another shows modifying a password with similar fields.
Guarantee
Customer Information:
- Customer Name: [Blank Field]
- Customer Calls: [Blank Field]
- Purchase Date: [Blank Field]
- Product Name: [Blank Field]
- Product Model: [Blank Field]
Notes:
- Please keep this card for warranty service.
- A one-year warranty is provided from the date of purchase.
- This warranty service is valid globally.
FCC Compliance
FCC Rules Statement:
- This device complies with part 15 of the FCC Rules.
- Operation is subject to two conditions: (1) it may not cause harmful interference, and (2) it must accept any interference received.
- Changes or modifications not expressly approved by the responsible party could void the user's authority to operate the equipment.
NOTE:
- This equipment has been tested and found to comply with Class B digital device limits per Part 15 of the FCC Rules.
- These limits provide reasonable protection against harmful interference in residential installations.
- The equipment generates, uses, and radiates radio frequency energy, and may cause interference if not installed and used per instructions.
- No guarantee of no interference in a particular installation.
- If interference occurs, users are encouraged to try corrective measures such as reorienting the antenna, increasing separation, connecting to a different circuit, or consulting a dealer/technician.
- The device has been evaluated for general RF exposure requirements and can be used in portable exposure conditions without restriction.
- FCC ID: 2AY4QH01A-TYAZ