Instruction Manual for SECURITECH models including: TEL-KLT-AP, TEL-KLT-AP Keyed Lever Trim, Keyed Lever Trim, Lever Trim, Trim

tel-klt-ap installation instructions

17 нояб. 2024 г. — TEL-KLT-AP Keyed lever trim. TEL-KDT-AP Keyed lever trim with 24 VDC release (Fail-Secure). TEL-KRT-AP Keyed lever trim with 24 VDC release (Fail-Safe).


File Info : application/pdf, 8 Pages, 1.05MB

PDF preview unavailable. Download the PDF instead.

aadss1252153
&
INSTALLATION INSTRUCTIONS:
TEL-KLT-AP

Use with Series: Tool(s) Required:

TRIDENT SERIES MODELS
Hex key (#1/8", #5MM) Phillips head screw drivers Nut drivers Drill with drill bits* *see templates for all sizes of drill bits needed

KEYED LEVER TRIM ON FULL ANTI-PRY PLATE FOR SELF-
RELOCKING MODELS

Damage caused by misuse of power tools is not covered under Warranty.
Before beginning the installation: · Check that everything in the parts list was received.
Parts received may be slightly different from parts shown in instructions. Please refer to packing list for details on parts and fasteners received. · Read all of the installation instruction steps.
Questions? Please call Tech Support
718-392-9000

INS-00092 -- Rev: A Date: 03-17-23

54-60 46th St., Maspeth, NY 11378 www.securitech.com 718-392-9000

Page 1 of 8

TEL-KLT-AP INSTALLATION INSTRUCTIONS
A. TEL-KLT-AP OVERVIEW
Exterior view

TRIDENT TEL-KLT-AP Features: · Key or electric release models to tie into access control systems
or remote release option available on all models · Frangible (break-off) lever (not available for G3 - Tubular lever) · ADA Compliant
Trims for self-relocking Tridents on full anti-pry plate: TEL-KLT-AP Keyed lever trim TEL-KDT-AP Keyed lever trim with 24 VDC release (Fail-Secure) TEL-KRT-AP Keyed lever trim with 24 VDC release (Fail-Safe) TEL-KLST-AP Keyed lever trim w/delayed egress shunt switch TEL-KDST-AP Keyed lever trim with 24 VDC release (Fail-Secure) w/delayed egress shunt switch
Trims for self-relocking dispensary Tridents on full anti-pry plate: TEL-MD-KLT-AP Keyed lever trim TEL-MD-KDT-AP Keyed lever trim with 24 VDC release (Fail-Secure) TEL-MD-KRT-AP Keyed lever trim with 24 VDC release (Fail-Safe) TEL-MD-KLST-AP Keyed lever trim w/delayed egress shunt switch TEL-MD-KDST-AP Keyed lever trim with 24 VDC release (Fail-Secure) w/delayed egress shunt switch

TABLE OF CONTENTS
A. TEL-KLT-AP Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 B. Cylinder Requirements, Preparation and Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 C. Door Preparation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 D. Setting the Spindle. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 E. Trim Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 F. Wiring Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 G. Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 H. Maintenance Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Call Tech Support for questions: 718-392-9000 INS-00092 -- Rev: A Date: 03-17-23

Page 2 of 8

TEL-KLT-AP INSTALLATION INSTRUCTIONS
B. CYLINDER REQUIREMENTS, PREPARATION AND INSTALLATION

IMPORTANT: Failure to follow cylinder and cam installation procedure may cause lock failure. Using cams that are not listed, or exact equals, may cause lock failure and void warranty.

CLOVERLEAF CAM:

· Ilco: 863S

· Best: C161 · Ilco: R2800S#3-00-10

· Ilco: 863D

CYLINDER PREPARATION
MORTISE CYLINDER: Thread size: 1.150 x 32 UNS Length: 1", 1-1/8", 1-1/4" or 1-3/8" Insert mortise cylinder and coil spring into cylinder collar.

CYLINDER INSTALLATION 1 Insert hex key (1/8") into cylinder locking screw and rotate counterclockwise to loosen cylinder locking arms.
2 Install cylinder with coil spring and collar into exterior trim by partially inserting key into cylinder and rotating cylinder clockwise into the trim until it bottoms out against the trim back plate. Then rotate counter-clockwise one full rotation to back cam away from back plate.

Cylinder locking screw

#1/8"

3 Insert hex key (1/8") into cylinder locking screw and rotate clockwise to lock cylinder in place. Jiggle cylinder clockwise/ counter-clockwise to be certain that cylinder locking arms are fully seated into cylinder slots.

Cylinder locking screw

#1/8

Note: Check operation. If cylinder is rotated too deep into trim, back plate will prevent it from functioning. If this happens, rotate cylinder counterclockwise 1-2 rotations.

Call Tech Support for questions: 718-392-9000 INS-00092 -- Rev: A Date: 03-17-23

Page 3 of 8

1) NEW INSTALLATION
1 Follow instructions on the trim template to mark and drill all holes for mounting the trim.

TEL-KLT-AP INSTALLATION INSTRUCTIONS
C. DOOR PREPARATION
Exterior view

2X 9/32" EXT 3/8" INT
1/2" EXT (TEL-KDT/KDX ONLY)
LINE UP WITH EXISTING THRU HOLES

1-5/16"

4X 9/32" THRU

1/2" EXT (TEL-KDX ONLY) LINE UP WITH EXISTING THRU HOLES

NOT TO SCALE

TMP TEL-KLT-AP DOOR MARKING TEMPLATE FOR TRIDENT
KEYED LEVER TRIM ON FULL ANTI-PRY PLATE

DOOR TYPE HOLLOW METAL
FOR REFERENCE ONLY. ALL HOLES ARE DRILLED IN THE FIELD DURING INSTALLATION.

LHR
TAPE TO EXTERIOR FACE OF DOOR

1/2" EXT WIRED MODELS ONLY

SECURITECH GROUP, INC.

54-60 46TH STREET MASPETH, NY 11378

PH: 718.392.9000

FAX: 718.392.8944

WWW.SECURITECH.COM

3/8" THRU

4-3/8"

1-5/16" THRU

3/8" THRU
LINE UP WITH EXISTING THRU HOLES

1-15/32"

CENTERLINE OF MECHANISM

1-15/32"

1-27/32"

1/2" EXT KDX MODELS ONLY

5-5/32"

3/8" THRU

2-1/8" 21/32"

TO SCALE CHECK THAT TEMPLATE IS PRINTED TO SCALE

1

2

3

5-29/32" 4

3/8" THRU

5 INCH

DOC # TMP-00003 REV C (03-17-23)

3-1/4"
LOCK SIDE

LHR shown

2) ADDING TRIM TO EXISTING INSTALLATION

1 Remove mechanism and antipry plate from the door. Exterior spindle hole should be already drilled from mechanism installation. If spindle hole is not drilled, follow instructions on trim template.

Exterior trim spindle hole

2 Follow instructions on the trim template to mark and drill all holes for mounting the trim.

Exterior view

NOTE: Two of the mounting holes for trim are different than previously installed antipry plate. Cover holes on interior using following parts:
For LHR: (2) flat washers and (1) 3/8" hole plug
For RHR: (2) 3/8" hole plugs.

LHR Washer
Plug
Washer RHR Plug

2X 9/32" EXT 3/8" INT
1/2" EXT (TEL-KDT/KDX ONLY)
LINE UP WITH EXISTING THRU HOLES

1-5/16"

4X 9/32" THRU

1/2" EXT (TEL-KDX ONLY) LINE UP WITH EXISTING THRU HOLES

NOT TO SCALE

TMP TEL-KLT-AP DOOR MARKING TEMPLATE FOR TRIDENT
KEYED LEVER TRIM ON FULL ANTI-PRY PLATE

DOOR TYPE HOLLOW METAL
FOR REFERENCE ONLY. ALL HOLES ARE DRILLED IN THE FIELD DURING INSTALLATION.

LHR
TAPE TO EXTERIOR FACE OF DOOR

1/2" EXT WIRED MODELS ONLY

SECURITECH GROUP, INC.

54-60 46TH STREET MASPETH, NY 11378

PH: 718.392.9000

FAX: 718.392.8944

WWW.SECURITECH.COM

3/8" THRU

4-3/8"

1-5/16" THRU

3/8" THRU
LINE UP WITH EXISTING THRU HOLES

1-15/32"

CENTERLINE OF MECHANISM

1-15/32"

1-27/32"

1/2" EXT KDX MODELS ONLY

5-5/32"

3/8" THRU

2-1/8" 21/32"

TO SCALE CHECK THAT TEMPLATE IS PRINTED TO SCALE

1

2

3

5-29/32" 4

3/8" THRU

5 INCH

DOC # TMP-00003 REV C (03-17-23)

3-1/4"
LOCK SIDE

LHR shown

Plug

Call Tech Support for questions: 718-392-9000 INS-00092 -- Rev: A Date: 03-17-23

Page 4 of 8

TEL-KLT-AP INSTALLATION INSTRUCTIONS
D. SETTING THE SPINDLE

IMPORTANT: Spindle must be set properly before mounting trim.

1 Hold trim in orientation shown. Manually turn the spindle by hand clockwise until stopped. Make sure spindle is on the square, not on the diamond.

LHR RHR

SPINDLE ORIENTATION

Correct Incorrect
1 Extend main bolt by pressing trigger prior to installing the trim.

IMPORTANT: If spindle does not land on the square, call Securitech.

E. TRIM INSTALLATION

Trigger sits behind main bolt

3 Align trim so the spindle fits into hub and posts on plate fit into holes on mechanism.

2 If wired, connect the wiring from trim to power transfer.
NOTE: Make sure that the wires don't get pinched between the trim and the door.

4 Secure trim to mechanism. At the front side of the mechanism, secure trim posts with (2) flat washers, (2) acorn nuts, and (2) K-lock nuts.

Call Tech Support for questions: 718-392-9000 INS-00092 -- Rev: A Date: 03-17-23

Page 5 of 8

5 At rear side of mechanism, secure trim posts with (2) acorn nuts and (2) K-lock nuts.

TEL-KLT-AP INSTALLATION INSTRUCTIONS
7 Check that exterior trim lever can smoothly retract main bolt after it is unlocked by key. To test again, relock the door.

6 Secure remaining trim posts with (2) T-nuts by the edge of the door.
NOTE: Do not overtighten. A compressed door can cause mechanism to fail.

T-nut

8 If new installation, continue with 5MM installation of top and bottom bolt modules.

If adding trim to existing installation, reinstall parts previously taken off the door.

T-nut

F. WIRING INFORMATION

SOLENOID

BLACK BLACK

KDT/KRT MODELS POWER TRANSFER DEVICE
Wires Cross from Door to Frame NOTE: Examples of Power Transfer Devices include Electric Hinges, Mini-Hinges or Surface Loops
Exterior Trim

KDST/KLST MODELS*

POWER TRANSFER DEVICE
Wires Cross from Door to Frame NOTE: Examples of Power Transfer Devices include Electric Hinges, Mini-Hinges or Surface Loops

KDST

} BLACK
WHITE

SOLENOID

} RED
GREEN

SHUNT SWITCH

4-Conductor Cable

KLST

} RED
GREEN

SHUNT SWITCH

2-Conductor Cable

* see additional wiring diagram and alarm instructions for applicable wiring information

Requires TEL-TCH (armored cable for electrified trim that includes alarm signal)

Exterior Trim

COMPONENT

POSITION

RESISTANCE

CURRENT

Solenoid DC 24V

Exterior Trim

90-105 Ohms

.300 Amps

Solenoid AC 24V COMPONENT

Exterior Trim POSITION

3.4-4.8 Ohms *30 V-A Transformer

2 Amps

MAX CONTACT RATINGS:

Shunt Switch

Exterior Trim

3 Amps at 125VAC

Note: when selecting wire gauge, comply with NEC sections 210.19(A), 215.2, and 230.42(A).
Call Tech Support for questions: 718-392-9000 INS-00092 -- Rev: A Date: 03-17-23

Page 6 of 8

TEL-KLT-AP INSTALLATION INSTRUCTIONS
G. OPERATING INSTRUCTIONS
1 Insert key into cylinder and rotate either clockwise or counter-clockwise to release lever. Note: Models with electric release function can also release lever by application of appropriate power from access control.
1

2 Rotate lever handle to retract bolts, and pull the door

open. Return the key to the center position and remove it.

2

3 Release lever handle upon entering.

4 Allow door to close and relock automatically.
IMPORTANT: The lock will relock automatically. Do not use the emergency exit paddle to pull the door closed. Damage may occur. Please add a door pull if needed (supplied by others).

4

Call Tech Support for questions: 718-392-9000 INS-00092 -- Rev: A Date: 03-17-23

Page 7 of 8

TEL-KLT-AP INSTALLATION INSTRUCTIONS
H. MAINTENANCE INFORMATION
MAINTENANCE: All products must be installed in accordance with the instructions and templates and by employing professional good trade practices or the warranty shall be void.
RECOMMENDED METHOD FOR CLEANING:
Powder-coated surfaces: Use a mild soap and water with a soft cloth or brush to clean powder-coated surfaces. Avoid using hard abrasives, such as wire brush, steel wool, or scouring powder. Avoid using harsh chemical cleaners, such as solvents or petroleum-based cleaning products. Before using any cleaner, first try cleaning a small test area.
Satin stainless steel: Use a non-chlorinated stainless steel cleaner (such as SSC, Surfox or similar) and a soft cloth. Any cleaner safe for glass is usually safe for stainless steel. Light surface rust can be easily removed by rubbing the surface with a brass, silver or chrome cleaner. Irreversible pitting will develop under rust that remains on stainless steel for extended period of time. Never clean with mineral acids or bleaches.
LOCKSETS AND EXIT DEVICES: Lever trims/exit devices are designed for life safety first. Securitech lever trims/exit devices are built to require minimal maintenance; however factors such as installation, severity of use, environmental conditions, and changes in the door opening may require that maintenance and/or adjustments be performed.
The following steps are recommended to the building owner to ensure proper operation: · Check that exposed screws are tight. · Check lockset and lever trims/exit devices for smooth operation periodically. · Check strikes and deadbolts to ensure they are secure and properly aligned. · Check deadbolt and other moving parts for binding or sluggish operation due to dirt or chemical buildup.
Check strikes for debris. · Clean parts according to aforementioned cleaning methods. Supplied products are factory lubricated
with white lithium grease and red high pressure lubricants. Do not use petroleum-based lubricant since it can dissolve grease. Lightly spray PTFE lubricant on moving parts including the trigger assembly (if applicable). Do not over lubricate.
FREQUENCY: The procedures mentioned above need to be carried out as often as is necessary to prevent deterioration in the installed environment, however we recommend the following minimum frequency of inspection: · General environments: Every 3 months · Marine and industrial environments: Every 2 months
A record of preventive maintenance and cleaning must be maintained and submitted with any warranty claims or service requests.

Call Tech Support for questions: 718-392-9000 INS-00092 -- Rev: A Date: 03-17-23

Page 8 of 8


mPDF 8.2.2