Hikvision DS-PM1-I16O2-WE Multi IO Transmitter Quick Start Guide
Model: DS-PM1-I16O2-WE
1. Appearance
- 1. LED Indicator: Includes Alarm Indicator, Fault Indicator, and Enrollment Indicator.
- 2. Power Switch: Used to turn the device on or off.
- 3. Wiring Terminal: For connecting external devices and power.
- 4. Tamper Switch: Detects if the device casing is opened.
- 5. Battery Holder: For installing a backup battery.
2. Setup and Wiring
Follow these steps for initial setup:
- Open the device shell.
- Wiring: Connect the necessary components as follows:
- A. Battery Plug: Connects the battery.
- B. Power Supply: Connects to a 100 to 240 VAC power source.
- C. Power Supply: Connects to -EXT and +EXT terminals for external power, or AUX- and AUX+ for auxiliary power.
- a. Alarm Output: Connects to PGM1 and C1 terminals for alarm signaling.
- b. Alarm Input: Connects to PGM2 and C2 terminals for input signals.
- Detector Connections (b1-b5):
- b1. NC Detector (Normally Closed)
- b2. NO Detector (Normally Open)
- b3. Tamper-proof connection
- b4. Dual-Zone Series Connection
- b5. Dual-Zone Parallel Connection
- D. Zone Input: Connects up to 16 zones (Z1 to Z16) and a common terminal (C).
- Installation: Mount the device according to installation instructions.
- Setup with App: Configure the transmitter using the dedicated mobile application.
- Power On: Connect the power supply and turn the transmitter on.
LED Status Indicators:
- Alarm: Solid red for 2 seconds.
- Fault Alarm: Solid amber.
- Enrollment Completed: Flashing green 7 times.
3. Specifications
| Feature | Specification |
|---|---|
| RF Frequency | 868 MHz |
| Modulation | 2GFSK |
| Method | Two-way communication |
| RF Distance | 800 m (open area) |
| Zone Input | 16 |
| EOL (End of Line) Resistors | 1K, 2.2K, 4.7K, 8.2K |
| Tamper Switch | 2 (Front and Rear) |
| Relay Output | 2 |
| 12 V Input | 1, Connects to the Battery |
| 12 V Output | 2-channel |
| Power Switch | Total Consumption: 1 A |
| Series Port | 1 |
| LED Status | 3: Alarm/Tamper (Red), Fault (Amber), Signal Strength (Green/Red) |
| Power Supply | 100 to 240 VAC |
| Operation Temperature | -10°C to 40°C |
| Operation Humidity | 10% to 90% |
| Dimension (W x H x D) | 199 x 261 x 86.4 mm |
| Weight | 975 g (without battery) |
| Note | The maximum altitude to use the transmitter is 5000 m. |
Diagram Descriptions
The document includes several diagrams illustrating the device and its connections:
- Diagram 1 (Appearance): Shows the physical layout of the Multi IO Transmitter with numbered components corresponding to the 'Appearance' section.
- Diagram 2 (Setup Steps): Visually guides through the setup process, including opening the device, wiring terminals (Battery Plug, Power Supply, Alarm Output/Input, Zone Inputs), and connecting detectors (NC, NO, Tamper, Dual-Zone configurations). It also shows the app setup and power-on sequence.
- Diagram 3 (Wiring Example): Provides a detailed view of the wiring terminal block, showing the labels for each connection point (Z1-Z16, C, AUX, -EXT, +EXT, PGM1, C1, PGM2, C2).
- Diagram 4 (Detector Connections): Illustrates various ways to connect security detectors, including normally closed (NC) and normally open (NO) types, tamper switches, and dual-zone configurations (series and parallel).
- Diagram 5 (App Setup): Depicts a smartphone interface with a QR code, indicating the use of a mobile application for device configuration and enrollment.