How to Configure Automation Device in AX PRO Wireless Control Panel
Product: DS-PWA Series AX PRO Wireless Security Control Panel
Version: v1.0
Date: 11/07/2020
Page: 1 of 5
Preparation
- DS-PWA Series AX PRO Wireless Security Control Panel
- Automation Device (Relay Module) DS-PM1-O1L-WE and Wireless Keyfob
- IE Browser and Hik-Connect App
1. Use Event Type to Control Automation Device
- Add the Automation Device to AX PRO first.
- Login to AX PRO, navigate to Device > Automation > Configuration.
- Configure the Original Status: Normal Open or Normal Close.
- Configure Tamper Input: If a third-party device's tamper signal is connected, enable this function. Select the Tamper Input Status (NO or NC).
- Configure Event Linkage: Define how events trigger the automation device.
Note: AND Mode requires all selected zones to be triggered for the relay to activate.
Event Type Configuration Options:
Schedule Configuration:
Configure a time period for the Automation Device to be normally open or normally closed.
Event Type | Parameter Setting |
---|---|
Alarm | Period 1 |
Schedule | Enable |
Arm | Time |
Disarm | Contact Status |
Silence Alarm | Period 2 |
Fault | Enable |
Manual | Time |
Disarm Configuration:
Link the Disarm Event to open or close the Automation Device.
Event Type | Parameter Setting |
---|---|
Alarm | Activation Mode: Pulse |
Schedule | |
Arm | Pulse Duration: 5 s |
Disarm | Range: 5-600 s |
Silence Alarm | Contact Status: Normally Closed |
Silence Alarm Configuration:
Link the Silence Alarm Event to open or close the Automation Device.
Event Type | Parameter Setting |
---|---|
Alarm | Activation Mode: Pulse |
Schedule | Pulse Duration: 5 s |
Arm | Range: 5-600 s |
Disarm | Contact Status: Normally Closed |
Silence Alarm | |
Fault | |
Manual |
Fault Configuration:
Link System Fault Events to open or close the Automation Device.
Event Type | Parameter Setting |
---|---|
Alarm | Communication Fault |
Schedule | Zone/Peripheral Poll Failure/Offline |
Arm | Zone/Peripherals Low Battery |
Disarm | Network Camera Disconnected |
Silence Alarm | Activation Mode: Pulse |
Fault | Pulse Duration: Range 5-600 s |
Manual | Contact Status: Normally Open |
Manual Configuration:
Manually control the Automation Device (open or close) via Hik-connect.
Event Type | Parameter Setting |
---|---|
Alarm | Activation Mode: Latch |
Schedule | |
Arm | |
Disarm | |
Silence Alarm | |
Fault | |
Manual |
2. Use Keyfob to Control Automation Device
- Add the Automation Device and wireless keyfob to AX PRO first.
- Configure Keyfob Button linkage to Automation Control, and select the relay number.
Name | Keyfob 1 | ||
---|---|---|---|
Serial No. | Q02017114 | ||
Enable Keyfob | |||
Linked User | installer |
Button Configuration:
Button | Action | Device | ||
---|---|---|---|---|
I Key | Silent Panic Alarm | - | ||
II Key | Automation Control | - | Relay 1 | - |
I + Arm Keys | None | - | ||
II + Disarm Keys | None | - | ||
I + II Keys | None | - | ||
Arm + Disarm | None | - |
- Configure Automation Control Device Event Type to Manual, select Activation Mode and Pulse Duration.
Activation Mode:
- Pulse: Relay outputs for a short period and then stops.
- Latch: Relay outputs continuously.