TS
Knowledge Beyond Measure.
OmniTrak™ Solution Modules
Efficiency Meets Intelligence. Customizable, Scalable, and Affordable Monitoring.
The OmniTrak™ Solution Smart Station pairs seamlessly with any OmniTrak™ module to provide immediate, on-site visibility into indoor environmental conditions. View live measurements, generate reports, and analyze data in real time to identify issues and drive informed improvements to air quality.
Product | Part Number |
---|---|
Smart Station | 7590-00 |
VOC-PID (ppb) Module | 7591-03 |
CO Module | 7591-06 |
CI Module | 7591-10 |
HCHO Module | 7591-07 |
O3 Module | 7591-08 |
NH3 Module | 7591-11 |
VOC-PID (ppm) Module | 7591-02 |
PM Module | 7591-01 |
PM + VOC-PID (ppm) Module | 7591-04 |
Core Module | 7591-05 |
An image displays the TSI OmniTrak™ system, featuring a central Smart Station unit, a Core Module, and a VOC-PID Module. A smartphone screen shows real-time sensor data, including particle counts and VOC levels. The overall setup highlights immediate, on-site visibility into indoor environmental conditions.
Features and Benefits
- Wireless connection for up to 10 modules simultaneously
- Large touch-screen with intuitive navigation used for recording studies, managing data, viewing historical data, real-time measurements, etc.
- Download data directly from the device onto your PC or upload data to our TSI Link™ cloud platform for easy accessibility
- Unique laser-based light scattering particle sensors - outputs mass concentration data (PM1, PM2.5, PM4, PM10) and particle number concentration data separated into 5 distinct bins
- Precise 10.6 eV PID (photo ionization detector) for monitoring various VOCs (volatile organic compounds) in the PPM and PPB ranges
- Accurate, high sensitivity VOC detection at low concentrations with the Core Module's electrochemical VOC Sensor
- Modular design allows the flexibility and connection to future next generation modules
Applications
- Ventilation effectiveness testing
- IAQ studies in commercial/residential buildings, schools, hospitals, industrial manufacturing, etc.
- Industrial/occupational hygiene surveys and indoor air quality investigations
- Identify air quality hot-spots. Pinpoint problem areas and investigate sources of poor indoor air quality
- Pre and post-remediation air testing. Validate the impact of air purifiers, ventilation upgrades, or renovation projects on indoor air quality
- Compare air quality by zone. Monitor and compare IAQ data across different rooms, floors, or building zones over time
- Support Manufacturing Quality Control. Track environmental conditions that could affect product quality in production areas
- Engineering control evaluations
A stylized bar chart graphic illustrates data distribution or trends, suggesting the system's capability to analyze and present environmental data.
Module Sensor Specifications
Measurement specifications apply at ambient conditions of 21 +/- 5 °C temperature, 98.6 +/- 5 kPa pressure, and 50 +/- 10% relative humidity.
Sensor Model | Sensor Type | Range | Accuracy | Resolution | Response Time |
---|---|---|---|---|---|
Core Module 7591-05 | CO2: NDIR (non-dispersive infrared) Barometric Pressure (BP): Piezoresistive Relative Humidity (RH): — Temperature (T): — PM Sensor: — VOC-EC (ppb) Sensor: Electrochemical | CO2: 400 - 10,000 ppm BP: 7.7 - 37.2 inHg (260-1260 hPa) RH: 5 - 95% RH T: 0 - 60 °C (32-140 °F) PM Sensor: See separate PM Sensor Specifications VOC-EC (ppb) Sensor: 0-10,000 ppb | CO2: +/- 3% of reading + 30 ppm (typical) BP: ± 0.12 in Hg (± 4.1 hPa) RH: +/- 5% RH T: +/- 0.5°C (+/- 0.9°F) PM Sensor: See separate PM Sensor Specifications VOC-EC (ppb) Sensor: — | CO2: 1 ppm BP: 0.01 in Hg (0.1 hPa) RH: 0.1% RH T: 0.10°C (0.18°F) PM Sensor: See separate PM Sensor Specifications VOC-EC (ppb) Sensor: 1 ppb | CO2: t90 < 60 seconds BP: — RH: — T: — PM Sensor: t50 < 50 seconds VOC-EC (ppb) Sensor: t50 < 50 seconds |
VOC-PID (PPB) Module Model 7591-03 | PID (Photo Ionization Detector) | 0 - 20,000 ppb | 1 ppb | 1 ppb | 15 seconds |
VOC-PID (ppm) Module Model 7591-02 | PID (Photo Ionization Detector) | 0 - 2,000 ppm | 0.1 ppm | 0.1 ppm | <10 seconds |
PM + VOC-PID (ppm) Module Model 7591-04 | VOC-PID (ppm) PID (Photo Ionization Detector) PM Sensor | 0 - 2,000 ppm See separate PM Sensor Specifications | 0.1 ppm See separate PM Sensor Specifications | 0.1 ppm See separate PM Sensor Specifications | <10 seconds t50 < 50 seconds |
Ammonia (NH3) Module Model 7591-11 | Electrochemical | 0 - 100 ppm | +/- 10 ppm | 0.1 ppm | 15 seconds |
Carbon Monoxide (CO) Module Model 7591-06 | Electrochemical | 0 - 400 ppm | 15% + 2 ppm | 0.1 ppm | 45 seconds |
Chlorine (C12) Module Model 7591-10 | Electrochemical | 0 - 20 ppm | 5% + 0.8 ppm | 0.01 ppm | 90 seconds |
Formaldehyde (HCHO) Module Model 7591-07 | Electrochemical | 0 - 10 ppm | 2% + 1 ppm | 0.01 ppm | 300 seconds |
Ozone (O3) Module Model 7591-08 | Electrochemical | 0 - 20 ppm | 15% + 1.5 ppm | 0.01 ppm | 60 seconds |
PM Sensor Specifications
PM Modules Models: 7591-01 PM Module, 7591-04 PM + VOC-PID (ppm) Module, 7591-05 Core Module
Particle Counter | Particulate Mass | |||||||
---|---|---|---|---|---|---|---|---|
Concentration Range | Particle Bins and Particle Size Range (NC = Number Concentration) | Concentration Precision¹ for PM0.5, PM1, and PM2.5² | Concentration Precision¹ for PM4, PM10³ | Concentration Range | Mass Concentration Bins and Particle Size Range | Mass Concentration Precision¹ for PM1, and PM2.5² | Mass Concentration Precision¹ for PM4, PM10³ | |
0 to 3,000 (#/cm³) (0 to 84,950,000 (#/ft³)) | NC0.5: 0.3 to 0.5 µm NC1.0: 0.5 to 1.0 µm NC2.5: 1.0 to 2.5 µm NC4: 2.5 to 4.0 µm NC10: 4.0 to 10.0 µm | 0 to 1,000 #/cm³ (0 to 28,320,000 #/ft³): ±100 (±2,832,000) #/cm³ (#/ft³) 1000 to 3000 #/cm³ (28,320,000 to 84,950,000 #/ft³): ±250 (±7,080,000) #/cm³ (#/ft³) | 0 to 1,000 #/cm³ (0 to 28,320,000 #/ft³): ±10 % m.v. 1000 to 3000 #/cm³ (28,320,000 to 84,950,000 #/ft³): ±25 % m.v. | 0 to 1,000 µg/m³ | PM1.0: 0.3 to 1.0 µm PM2.5: 0.3 to 2.5 µm PM4.0: 0.3 to 4.0 µm PM10.0: 0.3 to 10.0 µm | 0 to 100 µg/m³: + [5 µg/m³ + 5% m.v.] 100 to 1000 µg/m³: ±10 % m.v. | 0 to 100 µg/m³: ±25 µg/m³ 100 to 1000 µg/m³: ±25 % m.v. |
Response time for both Particle Counter and Particle Mass: t90 < 13 seconds. ¹ Also referred to as "between-parts variation" or "device-to-device variation". ² Verification Aerosol for PM2.5 is a 3% atomized KCI solution. Deviation to reference instrument is verified in end-tests for every sensor after calibration. ³ PM4 and PM10 output values are calculated based on distribution profile of all measured particles.
Specifications OmniTrak™ Solution Modules
Power Requirements
- Input Power: 10 W
- Input Voltage: 5 VDC
- Charging Port: USB C
Environmental/Installation Requirements
- Maximum Altitude: 3,000 m (10,000 ft)
- Pollution Degree: 2
- Installation Category: —
- Operating Temperature: 5°C to 40°C
- Storage Temperature: -20°C to 60°C
- Humidity: 0% to 95% (non-condensing)
- BLE Range**: up to 100 m (328 ft)
Battery Life
- Core Module: 15 hrs.
- Standard Modules: 18 hrs.
- Smart Station: 14 hrs.
Weight
- Core Module: 0.18kg (0.38lbs)
- Standard Modules: 0.17 kg (0.37 lbs)
- Smart Station: 0.36 kg (0.79 lbs)
Dimensions
- Core Module: 85 x 35 x 127 mm
- Standard Modules: 85 x 35 x 73 mm
- Smart Station: 85 x 35 x 175 mm
Sample Interval
- Standard and Core Modules: Every 1 sec
- Core Module CO2: Every 5 sec
Applies to both Smart Station and Modules. Range is dependent on many variables (i.e. wireless traffic, metal, etc.) and can not be guaranteed.
A series of vertical bars, resembling a simplified histogram or data visualization, is displayed, possibly representing data points or system status.
To Order
Specify | Description |
---|---|
7590-12 | Small Case for Smart Station + 2 Modules (Core or Standard) |
7590-22 | Large Case for Smart Station + 5 Modules (Core or Standard) |
7590-52 | OmniTrak Kick Stand, Hand & Wrist Strap |
7590-84 | Core calibration shroud |
TSI Incorporated - Visit our website www.tsi.com for more information.
Contact Information
USA
Tel: +1 800 874 2811
UK
Tel: +44 149 4 459200
France
Tel: +33 1 41 19 21 99
Germany
Tel: +49 241 523030
India
Tel: +91 80 67877200
China
Tel: +86 10 8219 7688
Singapore
Tel: +65 6595 6388
P/N 5003070 Rev G ©2025 TSI Incorporated Printed in U.S.A.
Specifications are subject to change without notice. Wi-Fi is a registered trademark by the Wi-Fi Alliance. The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by [licensee name] is under license. Other trademarks and trade names are those of their respective owners. TSI, the TSI logo are registered trademarks of TSI Incorporated in the United States and may be protected under other country's trademark registrations.