ResMed Battery Guide

This guide provides essential information for running ResMed devices on battery power, covering battery types, maintenance, and compatibility with various ResMed products.

Introduction

Many users opt to power their ResMed devices, such as flow generators or ventilators, using battery power when mains electricity is unavailable. This guide is designed to assist users in understanding the requirements for operating a flow generator and/or humidifier from battery power, whether for camping, power backup, or other situations.

For users intending to run a ResMed device from a battery for a single night before recharging, the following pages offer guidance on specific battery and inverter/converter requirements.

Visual Description: The image depicts a typical battery power setup for a ResMed device. It includes a large, rectangular deep-cycle battery with red and black terminal clamps, a black cable adapter, a grey electronic converter box with cables, and a ResMed S9 device with a humidifier attached.

The Equipment: Batteries

Battery Basics

ResMed devices typically utilize rechargeable lead-acid batteries. These batteries operate on a principle where two dissimilar metals are immersed in an electrolyte, facilitating the flow of electrical current. A standard flooded lead-acid battery contains six banks of plates or cells, each producing 2.11 volts, resulting in a terminal voltage of 12.66 volts.

Lead-acid battery construction: The diagram illustrates the internal components of a lead-acid battery, showing the casing, lead (negative plate), lead oxide (positive plate), terminals, and electrolyte (acid surrounding the plates).

Types of Batteries

Batteries are manufactured for different purposes. The primary types discussed are:

Automotive Batteries

Designed for high current surges to start car engines, these batteries have numerous thin plates to maximize surface area. They are made of a lead "sponge" material that can be damaged by deep discharge. Automotive batteries should not be discharged beyond 30% before recharging and typically last about 30 deep cycles. They are rated in Cold Cranking Amps (CCA), indicating their ability to supply current at -20°C.

Deep-cycle Batteries

These batteries feature solid lead plates that are thicker, allowing for deeper discharges (up to 80% or more). They are rated in amp-hours (AH), indicating the current they can supply over a specific time. Note that CCA and AH are not directly correlated.

Marine Batteries

Similar to deep-cycle batteries, marine batteries have thick plates to support deeper discharges and are rated in amp-hours. Most are hybrid types and can be safely discharged up to 60% before recharging.

Caution: Always consult the battery manufacturer for specific discharge rate recommendations.

Other Types of Batteries

AGM, or Absorbed Glass Mat

AGM batteries are sealed and use Absorbed Glass Mats between the plates. They offer advantages over gelled and flooded batteries, including resistance to shock and vibration, spill-proof design, and lower shipping costs due to being non-hazardous. They also have a very low self-discharge rate, allowing for longer storage periods.

Gelled Electrolyte

Gelled batteries contain acid "gelled" with silica gel, preventing spills even if the battery is broken. However, they require lower charging voltages and can lose capacity if overcharged. In hot climates, water loss can also affect their lifespan.

Battery Maintenance

Lead-acid batteries can degrade over time due to lead sulphate crystal formation during discharge. To prevent sulphation, it is recommended to:

  1. Add a battery conditioner as per manufacturer instructions.
  2. Regularly check electrolyte levels and top up with demineralised water if needed.
  3. Use a hydrometer to check the specific gravity of the electrolyte in each cell to detect potential cell damage.

Storing a Battery

  1. Check electrolyte levels in cells with filler caps and add demineralised water if necessary, avoiding overfilling.
  2. Clean the battery top and terminal posts.
  3. Fully charge the battery.
  4. Store in a dry, cool place (above freezing) where it can be easily recharged.
  5. Keep the battery charged at 100% state-of-charge by recharging every two weeks to prevent sulphation.

Caution: Incorrect charging can damage battery cells or reduce service life. Always follow the battery manufacturer's charging instructions.

Inverters

Inverters convert DC power from a battery to AC power for devices. Common types include pure sine wave and modified sine wave inverters. Pure sine wave inverters produce a waveform similar to domestic power outlets and are generally more expensive.

Visual Description: The document shows waveform comparisons: a smooth, continuous sine wave for a "Pure sine wave" inverter and a blockier, stepped waveform for a "Modified sine wave" inverter.

Power Ratings

Inverters have power ratings indicating their continuous and surge (peak) power delivery capabilities. The continuous rating is for sustained use, while the surge rating is for short bursts of power.

Warning: It is recommended that inverters are certified by accredited testing organizations (e.g., VDE, TSU, BSI) in addition to CE or UL markings. Contact your local ResMed office for more information.

Minimum Inverter Requirements

The following tables detail the minimum inverter requirements for various ResMed products:

ResMed devices powered with inverter

Inverter type Products
Modified sine wave - 150 watt • AutoSet CS2/VPAP Adapt SV
• S7 series
• S9 series
• VPAP series
• VPAP Auto
• C-Series Tango
• S8 series
• S8 II series
• S9 series + H5i
• VPAP III series
• VPAP Malibu
Pure sine wave - 300 watt continuous
Peak/Surge rating - 500 watt
All products (except S9) with humidifier - HumidAire 2i, HumidAire 3i, H4i, H5i, C-Series heated humidifier • AutoSet CS2/VPAP Adapt SV
• C-Series Tango
• S7 series
• S8 series
• S8 II series
• Stellar series
• VPAP III series
• VPAP Malibu
• VPAP Auto

Note: VPAP series inverters should be used with the Battery Adapter Cable (p/n 22006).

Note: The original HumidAire must not be used with inverters.

Caution: The C-Series Tango with C-Series heated humidifier operates at 110V only.

Warning: Other ResMed heated humidifiers must not be used with inverters. Doing so may cause damage to the unit or serious injury. Check with the manufacturer if using a different brand of heated humidifier.

Converters

ResMed offers specific converters for the following products:

Product Converter
VPAP series DC-24 converter (p/n 26932) with Battery Adapter Cable (p/n 22006)
S9 series DC/DC converter 24V/90W (p/n 36970)
Stellar series Stellar DC/DC converter (p/n 24922)
Air10 series Air10 DC/DC converter (p/n 37297)

Why use a converter?

Visual Description: The image shows a ResMed branded converter with a power cord and a car cigarette lighter plug.

Connecting a converter/inverter to a battery

Most converters and inverters connect to a battery via a car cigarette lighter plug. This can be used with an auxiliary battery in a car or 4WD vehicle. For direct connection to battery terminals (e.g., when the battery is outside the vehicle), an adapter cable is required.

Visual Description: The image shows a red and black adapter cable with alligator clips on one end and a car cigarette lighter plug on the other.

This adapter cable provides a more energy-efficient connection by bypassing the vehicle's electrical system.

Warning: Do not attempt to start the vehicle engine while using a ResMed device powered by the vehicle battery, as dangerous voltage spikes can occur and damage the unit.

Battery size tables

The following tables provide battery size requirements for ResMed devices powered with an inverter or converter. These tables are based on an 8-hour usage period and include a 50% safety margin. Note that for automatic devices, the 95th percentile pressure is used.

ResMed devices powered with inverter

C-Series Tango

Product Treatment pressure* (cm H₂O) Current draw at 12 V DC (amps) Battery size for 8 hours use (amp-hours) (includes 50% safety margin)
C-Series Tango 6 0.63 8
8 0.73 9
10 0.84 10
12 0.94 11
16 1.16 14
20 1.39 17
C-Series Tango + C-Series heated humidifier (set to 4) 6 2.73 33
8 2.91 35
10 3.11 37
12 3.24 39
16 3.54 43
20 3.91 47

S8 Series

Product Treatment pressure* (cm H₂O) Current draw at 12 V DC (amps) Battery size for 8 hours use (amp-hours) (includes 50% safety margin)
S8 Lightweight
S8 Escape
6 1.02 12
8 1.12 13
10 1.24 15
12 1.36 16
16 1.62 19
20 1.90 23
S8 Lightweight + HumidAire 3i
S8 Escape + HumidAire 3i
6 3.75 45
8 3.84 46
10 3.96 48
12 4.09 49
16 4.34 52
20 4.63 56
S8 Elite
S8 AutoScore
S8 AutoSet Vantage
S8 AutoSet Spirit
S8 AutoSet C
S8 Respond (product code 33127)
6 1.13 14
8 1.27 15
10 1.40 17
12 1.52 18
16 1.81 22
20 2.12 25
S8 Elite + HumidAire 3i
S8 AutoScore + HumidAire 3i
S8 AutoSet Vantage + HumidAire 3i
S8 AutoSet Spirit + HumidAire 3i
S8 AutoSet C + HumidAire 3i
S8 Respond (product code 33127) + HumidAire 3i
6 3.86 46
8 4.00 48
10 4.12 50
12 4.25 51
16 4.54 54
20 4.85 58

S8 II series

Product Treatment pressure* (cm H₂O) Current draw at 12 V DC (amps) Battery size for 8 hours use (amp-hours) (includes 50% safety margin)
S8 Escape II (EPR-setting 3) 5 0.41 5
10 0.61 8
15 0.86 11
20 1.17 14
S8 Escape II (EPR-setting 3, full time) + H3i (set to 4) 5 4.99 60
10 4.91 59
15 5.93 71
20 6.08 73
S8 Escape II (EPR-setting 3, full time) + H4i (set to 4) 5 8.49 102
10 9.6 115
15 9.38 113
20 11.26 135
S8 Elite II
S8 AutoScore II
S8 AutoSet Spirit II
S8 AutoSet
S8 Respond (product code 33137)
6 0.91 11
8 0.94 11
1
10 1.09 13
12 1.20 14
16 1.48 18
20 1.76 21
S8 Elite II + HumidAire 3i
S8 AutoScore II + HumidAire 3i
S8 AutoSet Spirit II + HumidAire 3i
S8 AutoSet + HumidAire 3i
S8 Respond (product code 33137) + HumidAire 3i
6 3.46 41
8 3.36 40
10 3.66 44
12 3.84 46
16 3.77 45
20 4.51 54

S9 series (continued over page)

Product Treatment pressure* (cm H₂O) Current draw at 12 V DC (amps) Battery size for 8 hours use (amp-hours) (includes 50% safety margin)
S9 Elite (EPR Setting 0)
S9 AutoSet (EPR Setting 0)
6 0.89 11
8 0.95 12
10 1.02 12
12 1.08 13
16 1.23 15
20 1.41 17
S9 Elite + H5i (EPR Setting 0, H5i setting 3)
S9 AutoSet + H5i (EPR Setting 0, H5i setting 3)
6 2.57 31
8 2.76 33
10 3.01 36
12 3.32 40
16 3.77 45
20 4.10 49
S9 Elite + H5i (EPR Setting 0, H5i setting 6)
S9 AutoSet + H5i (EPR Setting 0, H5i setting 6)
6 4.94 59
8 5.45 65
10 5.90 71
12 6.18 74
16 6.47 78
20 6.69 80
S9 Elite + H5i + Climate control (EPR Setting 0, CC setting 27° C)
S9 AutoSet + H5i + Climate control (EPR Setting 0, CC setting 27° C)
6 3.05 37
8 3.69 44
10 4.12 49
12 4.48 54
16 6.06 73
20 7.25 87
S9 Elite + H5i + Climate control (EPR Setting 0, CC setting 30° C)
S9 AutoSet + H5i + Climate control (EPR Setting 0, CC setting 30° C)
6 3.32 40
8 3.78 45
10 4.20 50
12 4.71 57
16 5.68 68
20 6.49 78
IPAP pressure (cm H₂O)
S9 VPAP S/ VPAP ST
10 0.52 7
15 0.80 10
20 1.17 15
25 1.57 19
S9 VPAP S/VPAPST + H5i (H5i setting 3) 10 1.41 17
15 1.90 23
20 3.07 37
25 3.44 42

S9 VPAP Adapt SV-A, AutoSet CS/CS-A

Product EPAP pressure (cm H₂O) Current draw at 12 V DC (amps) Battery size for 8 hours use (amp-hours) (includes 50% safety margin)
S9 VPAP Adapt SV-A, AutoSet CS/CS-A 5 0.61 8
10 0.76 10
15 0.95 12
S9 VPAP Adapt SV-A, AutoSet CS/CS-A + H5i (H5i setting 3) 5 2.45 30
10 3.05 37
15 3.75 45
S9 VPAP Adapt SV-A, AutoSet CS/CS-A + H5i (H5i setting 6) 5 4.47 54
10 5.24 63
15 6.06 73
S9 VPAP Adapt SV-A, AutoSet CS/CS-A + H5i + Climate control (CC setting 30° C) 5 5.85 71
10 6.35 77
15 7.05 85

VPAP III series

Product IPAP pressure (cm H₂O) Current draw at 12 V DC (amps) Battery size for 8 hours use (amp-hours) (includes 50% safety margin)
VPAP III
VPAP III ST
5 1.19 15
10 1.42 17
15 1.67 20
20 1.93 23
25 2.21 27
VPAP III + HumidAire 2i
VPAP III ST + HumidAire 2i
5 3.57 43
10 3.81 46
15 4.06 49
20 4.32 52
25 4.59 55
VPAP III ST-A
VPAP III ST-A with QuickNav
5 1.65 20
10 1.86 22
15 2.11 25
20 2.41 29
25 2.76 33
30 3.15 38
VPAP III ST-A + HumidAire 2i
VPAP III ST-A with QuickNav + HumidAire 2i
5 4.04 48
10 4.25 51
15 4.49 54
20 4.79 58
25 5.15 62
30 5.54 66

Note: Table values are based on a respiratory rate of 20 breaths per minute. Power consumption increases with higher respiratory rates.

AutoSet CS2/VPAP Adapt

Device settings Inverter Median pressure support Current draw at 12 V DC (amps) Battery size for 8 hours use (amp-hours) (includes 50% safety margin) Battery size for 8 hours use (amp-hours) with H2i (includes 50% safety margin)
EEP 4 6 1.88 23 56
6 6 1.97 24 57
8 6 2.11 26 58
10 5 2.23 27 60

VPAP Malibu

Product AutoSet pressure (cm H₂O) Current draw at 12 V DC (amps) Battery size for 8 hours use (amp-hours) (includes 50% safety margin)
VPAP Malibu 10 1.56 21
20 2.35 29
VPAP Malibu + Humidaire 2i 10 6.58 79
20 7.53 91

VPAP Auto

PS (cm H₂O) AutoSet pressure <= 10 AutoSet pressure > 10
Current draw at 12 V DC (amps) Battery size for 8 hours use (amp-hours) (includes 50% safety margin) Current draw at 12 V DC (amps) Battery size for 8 hours use (amp-hours) (includes 50% safety margin)
2 0.89 11 1.40 17
4 0.87 10 1.32 16
6 0.86 10 1.23 15
8 0.89 11 1.17 14
10 0.85 10 1.07 13
PS (cm H₂O) AutoSet pressure <=10 AutoSet pressure > 10
Current draw at 12 V DC (amps) Battery size for 8 hours use (amp-hours) (includes 50% safety margin) Current draw at 12 V DC (amps) Battery size for 8 hours use (amp-hours) (includes 50% safety margin)
2 8.59 103 8.85 108
4 8.59 103 8.85 108
6 8.59 103 8.85 108
8 8.59 103 8.85 108
10 8.59 103 8.85 108

Stellar series

Product IPAP pressure (cm H₂O) Current draw at 12 V DC (amps) Battery size for 8 hours use (amp-hours) (includes 50% safety margin)
Stellar 10 1.25 16
15 1.27 16
20 1.42 18
25 1.59 20
30 1.77 22
35 2.21 27
40 2.47 30
Stellar + H4i (set to 4) 10 7.21 87
15 7.79 94
20 8.57 103
25 9.31 112
30 10.55 127
35 11.82 142
40 12.49 150

ResMed devices powered with converter

S8 series

Product Treatment pressure* (cm H₂O) Current draw at 12 V DC (amps) Battery size for 8 hours use (amp-hours) (includes 50% safety margin)
S8 Lightweight
S8 Escape
6 0.80 10
8 0.90 11
10 1.02 12
12 1.12 13
16 1.37 16
20 1.66 20
S8 Elite
S8 AutoScore
S8 AutoSet Vantage
S8 AutoSet Spirit
S8 AutoSet C
S8 Respond
6 0.90 11
8 0.98 12
10 1.09 13
12 1.21 14
16 1.46 18
20 1.73 21

S8 II series

Product Treatment pressure* (cm H₂O) Current draw at 12 V DC (amps) Battery size for 8 hours use (amp-hours) (includes 50% safety margin)
S8 Elite II
S8 AutoScore II
S8 AutoSet Spirit II
S8 AutoSet
S8 Respond
6 0.57 7
8 0.70 8
10 0.84 10
12 0.96 12
16 1.22 15
20 1.51 18
S8 Escape II (EPR-setting 3) 5 0.41 5
10 0.61 7
15 0.86 10
20 1.17 14

S9 Series (continued over page)

Product Treatment pressure* (cm H₂O) Current draw at 12 V DC (amps) Battery size for 8 hours use (amp-hours) (includes 50% safety margin)
S9 AutoSet/ Elite/ Escape/
Escape Auto
6 0.39 5
8 0.46 6
10 0.55 7
12 0.65 8
16 0.9 11
20 1.0 13
S9 AutoSet/ Elite/ Escape/
Escape Auto + H5i (H5i setting 3)
6 1.25 15
8 1.62 20
10 2.03 25
12 2.39 29
16 3.19 39
20 4.03 49
S9 AutoSet/ Elite/ Escape/
Escape Auto + H5i (H5i setting 6)
6 4.61 56
8 4.84 59
10 4.99 60
12 5.17 63
16 5.58 67
20 6.04 73
S9 AutoSet/ Elite/ Escape/
Escape Auto + H5i +
Climate control (CC setting 30° C)
6 4.27 52
8 5.08 61
10 5.58 67
12 5.77 70
16 6.15 74
20 6.59 79
IPAP pressure (cm H₂O)
S9 VPAP S/ VPAP ST
10 0.52 7
15 0.80 10
20 1.17 15
25 1.57 19
S9 VPAP S/VPAPST + H5i (H5i setting 3) 10 1.41 17
15 1.90 23
20 3.07 37
25 3.44 42

S9 VPAP Adapt SV-A, AutoSet CS/CS-A

Product EPAP pressure (cm H₂O) Current draw at 12 V DC (amps) Battery size for 8 hours use (amp-hours) (includes 50% safety margin)
S9 VPAP Adapt SV-A, AutoSet CS/CS-A 5 0.61 8
10 0.76 10
15 0.95 12
S9 VPAP Adapt SV-A, AutoSet CS/CS-A + H5i (H5i setting 3) 5 2.45 30
10 3.05 37
15 3.75 45
S9 VPAP Adapt SV-A, AutoSet CS/CS-A + H5i (H5i setting 6) 5 4.47 54
10 5.24 63
15 6.06 73
S9 VPAP Adapt SV-A, AutoSet CS/CS-A + H5i + Climate control (CC setting 30° C) 5 5.85 71
10 6.35 77
15 7.05 85

VPAP III series

Product IPAP pressure (cm H₂O) Current draw at 12 V DC (amps) Battery size for 8 hours use (amp-hours) (includes 50% safety margin)
VPAP III
VPAP III ST
5 1.19 15
10 1.42 17
15 1.67 20
20 1.93 23
25 2.21 27
VPAP III + HumidAire 2i
VPAP III ST + HumidAire 2i
5 3.57 43
10 3.81 46
15 4.06 49
20 4.32 52
25 4.59 55
VPAP III ST-A
VPAP III ST-A with QuickNav
5 1.65 20
10 1.86 22
15 2.11 25
20 2.41 29
25 2.76 33
30 3.15 38
VPAP III ST-A + HumidAire 2i
VPAP III ST-A with QuickNav + HumidAire 2i
5 4.04 48
10 4.25 51
15 4.49 54
20 4.79 58
25 5.15 62
30 5.54 66

Note: Table values are based on a respiratory rate of 20 breaths per minute. Power consumption increases with higher respiratory rates.

Air10 series (continued over page)

Product IPAP pressure (cm H₂O) Current draw at 12 V DC (amps) Battery size for 8 hours use (amp-hours) (includes 50% safety margin)
AirStart 10 + SlimLine tubing 6 0.39 5
8 0.48 6
10 0.53 7
12 0.61 8
16 0.80 10
20 1.01 13
AirStart 10 + SlimLine tubing + humidifier (set to 4) 6 1.28 16
8 1.49 18
10 1.66 20
12 1.84 23
16 2.28 28
20 2.66 32
AirStart 10 + SlimLine tubing + humidifier (set to 8) 6 3.14 38
8 3.31 40
10 3.44 42
12 3.67 45
16 4.00 48
20 4.34 53
AirSense 10 CPAP/Elite/ AutoSet/AutoSet for Her + ClimateLineAir (set to 30°C) 6 1.06 13
8 1.20 15
10 1.52 19
12 1.96 24
16 2.68 33
20 3.50 42
AirSense 10 CPAP/Elite/ AutoSet/AutoSet for Her + SlimLine tubing 6 0.70 9
8 0.79 10
10 0.93 12
12 1.06 13
16 1.23 15
20 1.66 20

AirSense 10 CPAP/Elite/ AutoSet/AutoSet for Her + SlimLine tubing + humidifier (set to 4)

Product IPAP pressure (cm H₂O) Current draw at 12 V DC (amps) Battery size for 8 hours use (amp-hours) (includes 50% safety margin)
AirSense 10 CPAP/Elite/ AutoSet/AutoSet for Her + SlimLine tubing + humidifier (set to 4) 6 1.73 21
8 2.00 24
10 2.30 28
12 2.61 32
16 3.33 40
20 4.19 51
AirSense 10 CPAP/Elite/ AutoSet/AutoSet for Her + SlimLine tubing + humidifier (set to 8) 6 3.44 42
8 3.49 42
10 3.66 44
12 3.86 47
16 4.18 51
20 4.59 56
AirSense 10 CPAP/Elite/ AutoSet/AutoSet for Her + ClimateLine Air tubing + humidifier (set to Auto) 6 3.12 38
8 3.55 43
10 3.77 46
12 4.02 49
16 4.21 51
20 4.35 53
AirSense 10 CPAP/Elite/ AutoSet/AutoSet for Her + ClimateLine Air tubing (set to 30°C) + humidifier (set to 8) 6 4.71 57
8 4.77 58
10 4.92 60
12 5.12 62
16 5.37 65
20 5.61 68

VPAP Malibu

Product AutoSet pressure (cm H₂O) Current draw at 12 V DC (amps) Battery size for 8 hours use (amp-hours) (includes 50% safety margin)
VPAP Malibu 10 1.09 13
20 1.74 21

VPAP Auto

PS (cm H₂O) AutoSet pressure <=10 AutoSet pressure > 10
Current draw at 12 V DC (amps) Battery size for 8 hours use (amp-hours) (includes 50% safety margin) Current draw at 12 V DC (amps) Battery size for 8 hours use (amp-hours) (includes 50% safety margin)
2 0.67 8 1.15 14
4 0.69 8 1.10 13
6 0.69 8 1.03 12
8 0.67 8 0.95 11
10 0.63 8 0.90 11

VPAP series (VPAP Auto 25, VPAP ST, VPAP S, VPAP IV, VPAP IV ST, S8 Auto 25)

IPAP (cm H₂O) Current draw at 12 V DC (amps) Battery size for 4 hours use (amp-hours) (includes 50% safety margin) Battery size for 8 hours use (amp-hours) (includes 50% safety margin)
10 1.0 6 12
15 1.2 7 14
20 1.5 9 18
25 1.8 11 22

Stellar series

Product IPAP (cm H₂O) Current draw at 12 V DC (amps) Battery size for 8 hours use (amp-hours) (includes 50% safety margin)
Stellar 10 0.66 8
15 0.76 10
20 0.86 11
25 0.97 12
30 1.11 14
35 1.24 15
40 1.38 17

Note: Where the H5i is being used, figures will vary depending upon relative humidity.

Models: Battery Cable Adapter Converter and S9 with Humidifier

File Info : application/pdf, 23 Pages, 462.95KB

PDF preview unavailable. Download the PDF instead.

battery-guide glo eng (Infix Pro)

Related Documents

Preview ResMed Therapy Devices Travel Compliance Letter
Official compliance letter from ResMed confirming that various ResMed therapy devices meet FAA and DOT air travel requirements, including electromagnetic compatibility (EMC) testing per RTCA/DO-160G, Section 21, Category M.
Preview ResMed Respiratory Assistive Devices FAA Travel Compliance Letter
Official travel compliance letter from ResMed confirming that their respiratory assistive devices meet FAA and DOT regulations for air travel, including compliance with RTCA/DO-160G standards. Lists numerous ResMed product models and their compliance status.
Preview ResMed Therapy Devices Travel Compliance Letter
Official letter from ResMed confirming that their respiratory assistive devices comply with RTCA/DO-160G, Section 21, Category M for air travel, ensuring safe operation on commercial aircraft.
Preview ResMed VPAP Malibu: Advanced Bilevel PAP Therapy
Discover the ResMed VPAP Malibu, a premium auto-adjusting bilevel device for effective sleep apnea treatment. Learn about its features, benefits, and technical specifications for comfortable and natural breathing.
Preview Manual del Usuario ResMed S8 AutoSet Vantage: Guía Completa
Explore el manual del usuario para el ResMed S8 AutoSet Vantage, un dispositivo de terapia para la apnea del sueño. Encuentre instrucciones detalladas, especificaciones y consejos de mantenimiento.
Preview ResMed S8 Elite™ CPAP Machine User Manual
Comprehensive user manual for the ResMed S8 Elite™ CPAP system, detailing setup, operation, maintenance, troubleshooting, and specifications for treating obstructive sleep apnea.
Preview ResMed S9 VPAP Series & H5i Welcome Guide: Setup, Operation, and Maintenance
Comprehensive welcome guide for ResMed S9 VPAP Auto, ST, and S Positive Airway Pressure Devices and the H5i Heated Humidifier. Learn about setup, operation, cleaning, maintenance, and troubleshooting.
Preview ResMed S9 AutoSet & S9 Elite Welcome Guide
A comprehensive welcome guide for ResMed S9 AutoSet and S9 Elite positive airway pressure devices, covering setup, operation, maintenance, and features.