Panasonic KX-NS300 System Capacity and Specifications

PFMPR Software File Version 7.0

System Capacity

Maximum Trunks

ComponentModel No.TypeStandalone/Slave UnitOne-look Networking*1
Total Number of TrunksWith 1 KX-NS320With 2 KX-NS320With 3 KX-NS320
KX-NS300100 [52]*2136 [88]*2172 [124]*2208 [160]*2600
IP-CS Channel Expansion (from 4 to 8 ch)KX-NSE2015 CS600
Channel ExpansionKX-NSE20510 CS600
LegacyKX-NSE21020 CS600
BRIKX-NSA0203672108144600
PRI23KX-NSF10123466992600
PRI30KX-NS5290306090120600
E1306090120600
Analogue12243648600
IPKX-NSM1022 ch64 [16]*264 [16]*264 [16]*264 [16]*2256
H.323KX-NSM1044 ch32 [16]*232 [16]*232 [16]*232 [16]*2128
Unified MessagingKX-NSU1022 ch
SIPKX-NSM1088 ch64 [16]*264 [16]*264 [16]*264 [16]*2256
ChannelKX-NSM11616 ch
User (Mailbox) Activation KeyKX-NSU201*51 user
Unified MessagingKX-NSU205*55 users
E-mail (IMAP4) Client/ E-mail NotificationKX-NSU210*510 users
KX-NSU220*520 users
KX-NSU299*5All users
Two-way Recording/ Two-way TransferKX-NSU3011 user
KX-NSU3055 users
KX-NSU31010 users
KX-NSU32020 users
KX-NSU399All users
CA Basic-ExpressKX-NSA2011 user
CA PROKX-NSA2055 users
KX-NSA21010 users
KX-NSA24040 users
KX-NSA249128 users
CommunicationKX-NSA301CA Supervisor
KX-NSA401CA Operator Console
Built-in VM (ch)*4KX-NSA9011 user2222
Built-in UM (ch)KX-NSA9055 users2424242430
TVM UnitKX-NSA91022228
CA Network Plug-inKX-NSA94010 users
KX-NSA94940 users
CA Thin ClientKX-NSA010128 users
Thin Client Server ConnectionKX-NSP0011 user
External RelayKX-NSP0055 users
External SensorKX-NSP01010 users
KX-NSP02020 users
StandardKX-NSP1011 user
KX-NSP1055 users
KX-NSP11010 users
KX-NSP12020 users
AdvancedKX-NSP2011 user
KX-NSP2055 users
KX-NSP21010 users
KX-NSP22020 users

*1 The NS1000 must be used as the master unit.

*2 The numbers enclosed in square brackets (e.g., [66 (80)]) are the capacities when the PBX is connected as a slave unit in a One-look network.

*3 When Digital XDP is used.

*4 Cannot be used with a slave unit.

*5 The total number of Door Openers and External Relays.

Maximum Terminal Equipment

SystemTypeStandalone/Slave UnitOne-look Networking*1
KX-NS300With 1 KX-NS320With 2 KX-NS320With 3 KX-NS320
Extensions (DXDP*3)162 (176) [66 (80)]*2194 (224) [98 (128)]2226 (272) [130 (176)]2258 (320) [162 (224)]21000
Legacy (DXDP*3)34 (48)66 (96)98 (144)130 (192)1000
SLT3264961281000
DPT (T76xx/DT5xx)(DXDP*3)18 (32)34 (64)50 (96)66 (128)512 (1000)
APT8162432336
IP128 [32]*2128 [32]*2128 [32]*2128 [32]*21000
IP-PT128 [32]*2128 [32]*2128 [32]*2128 [32]*21000
IP Phone128 [32]*2128 [32]*2128 [32]*2128 [32]*21000
DSS Console888864
CS36404448128
DPT-CS (2 ch)481216128
DPT-CS (8 ch)246864
IP-CS32323232128
SIP-CS16161616128
PS128128128128512
Doorphone246880
Door Opener25*54*56*58*580*5
External Sensor246880

Option List

Hardware

ComponentModel No.Installed in
DSPKX-NS5110S (63 resources)
KX-NS5111M (127 resources)
KX-NS5112L (254 resources)
KX-NS3134XS (VM Recording Time: 40 hours)
Storage Memory¹KX-NS3135S (VM Recording Time: 200 hours)
Storage Memory Card SlotKX-NS3136M (VM Recording Time: 400 hours)
LCOT6KX-NS5180
BR12KX-NS5282
BRI4KX-NS5284
PRI23KX-NS5290Trunk/Doorphone Slot
PRI30/E1KX-NS5290CETrunk/Doorphone Slot
DPH2KX-NS5162Extension Slot
DHLC4KX-NS5170Extension Slot
DLC8KX-NS5171Extension Slot
DLC16KX-NS5172Extension Slot
MCSLC8KX-NS5173Extension Slot
MCSLC16KX-NS5174Extension Slot
Expansion Master CardKX-NS5130EXP-M Slot
Remote ModemKX-TDA0196RMT Slot

*1 Storage Memory for VM Recording, ACD Report, SMDR expansion.

*2 Requires optional SD card.

*3 Requires KX-NSF201 or KX-NSXF022.

*4 IP PTs: KX-NT600/500/300 series IP proprietary phones, IP Phones: KX-HDV and KX-UT series, IP Camera/IP Video Doorphone: KX-NTV series

*5 Preinstalled on system firmware versions 5.0 and later.

Activation Keys for UC Pro 2

User Activation Keys (KX-UCPB Series)

ComponentModel No.
5 usersKX-UCPB0005W
10 usersKX-UCPB0010W
25 usersKX-UCPB0025W
50 usersKX-UCPB0050W
75 usersKX-UCPB0075W
100 usersKX-UCPB0100W
250 usersKX-UCPB0250W
500 usersKX-UCPB0500W
1000 usersKX-UCPB1000W

UC Pro V2 User AK

ComponentModel No.
UC Pro V2 User AKKX-UCPB0075W
UC Pro V2 User AKKX-UCPB0100W
UC Pro V2 User AKKX-UCPB0250W
UC Pro V2 User AKKX-UCPB0500W
UC Pro V2 User AKKX-UCPB1000W

UC Pro V2 Line AK

ComponentModel No.
UC Pro V2 Line AKKX-UCPM0005W
KX-UCPM0010W
KX-UCPM0025W
KX-UCPM0050W
KX-UCPM0075W
KX-UCPM0100W
KX-UCPM0250W
KX-UCPM0500W
KX-UCPM1000W

IP Softphones/Cameras/Phones

ComponentModel No.
IP PTS/IP Phones/ IP Camera/ IP Video Doorphone/ IP SoftphonesKX-UCPAB0005W
KX-UCPAB0010W
KX-UCPAB0025W
KX-UCPAB0050W
KX-UCPAB0075W
KX-UCPAB0100W
KX-UCPAB0250W
KX-UCPAB0500W
KX-UCPAB1KW

IP Telephone/Camera/Doorphone

ComponentModel No.Installed in
IP PTS/IP Telephone*4KX-NSM501Up to 4 ch
KX-NSM5055 ch
KX-NSM51010 ch
KX-NSM52020 ch
IP Camera/ IP Video DoorphoneKX-NSM7011 ch
KX-NSM7055 ch
KX-NSM71010 ch
KX-NSM72020 ch
3rd Party SIP PhonesKX-NSE1011 ch
KX-NSE1055 ch
KX-NSE11010 ch
KX-NSE12020 ch
Cellular Phone ExtensionKX-NSM2011 ch
Mobile ExtensionKX-NSM2055 ch
KX-NSM21010 ch
KX-NSM22020 ch

*3 Requires KX-NSF201 or KX-NSXF022.

*4 From UC Pro

Specifications

ItemDetailsKX-NS300KX-NS320
Main CPUCortex A8 600 MHzCortex A8 300 MHz
Power Input100 V AC to 130 V AC: 2.2 A/200 V AC to 240 V AC: 1.3 A; 50 Hz/60 Hz
Power Consumption (when fully mounted)110 W
Memory Backup Duration7 years
External Backup BatteryExternal battery port is supported.
DiallingTrunkDial Pulse (DP) 10 pps, 20 pps Tone (DTMF) Dialling
ExtensionDial Pulse (DP) 10 pps, 20 pps Tone (DTMF) Dialling
Mode ConversionDP-DTMF, DTMF-DP
Ring Frequency20 Hz/25 Hz (selectable)
TemperatureOperating Environment0°C to 40°C
HumidityOperating Environment10% to 90% (non-condensing)
Conference Call Trunk32 parties (default)/96 parties (DSP installed) (10 x 3-party conference call, 12 x 8-party conference call, etc.)
Music on Hold (MOH)Maximum 8 ports (Level Control: -31.5 dB to +31.5 dB per 0.5 dB) MOH: Selectable Internal/External Music Source Port
External PagingMaximum 6 ports (Volume Control: -15.5 dB to +15.5 dB per 0.5 dB)
LAN Port1 (for LAN connection) 10BASE-T/100BASE-TX (Auto MDI/MDI-X)
SLTExtension Connection Cable1-pair wire (T, R)
DPTExtension Connection Cable1-pair wire (D1, D2)
APTExtension Connection Cable2-pair wire (T, R, D1, D2)
PT-interface CS1-pair wire (D1, D2)
PT-interface CS (High-density)4-pair wire (D1, D2)
DSS Console and Add-on Key Module1-pair wire (D1, D2)
Air-cooling MethodFan
Dimension430 mm (W) x 367 mm (D) x 88 mm (H)
Weight (when fully mounted)Under 4.5 kg

System Feature Capacity

SystemItemCapacitySystemItemCapacity
Absent Message-Extension1 x 16 charactersARS Carrier48
Absent Message-System8 x 16 charactersRouting Plan Table16 digits, 1,000 entries
Call Park Zone100Leading Number Table16 digits, 200 entries
Conference3- 8 parties per conferenceLeading Number Exception Table48
COS32 parties (default)/96 parties (DSP installed)Itemised Billing Code10 digits
DID/DDI Table64Authorisation Code for Tenant16 digits
Extension number32 digits, 1,000 entriesAuthorisation Code for Trunk Group10 digits
Extension Personal Identification Number (PIN)1-5 digitsOutgoing Call Log-PT100 records/extn.
Host PBX Access Code10 digits, 1 entry/extensionOutgoing Call Log-PS1,520 records/system
Multiple Subscriber Number (MSN)10 digits, 10 entries/trunk groupCall Log and Incoming Call Log-PT100 records/extn.
Number of Characters of Name10 entries per ISDN-BRI portMessage Waiting-PS + Incoming Call Distribution Group640 records/system
Printing message20Message Waiting-PT+SLT100 records/extn. or group
Queuing Time Table8Outgoing Message (OGM)Total 2,560 records/system
Ring Tone Pattern Plan64OGM Total Recording Time256
Simultaneous Programmers8Build-in Simplified Voice Message (SVM)256
Simultaneous Programmers (Web Maintenance Console)• 1 system programmer + 63 personal programmers • 1 manager programmer + 63 personal programmers • 64 personal programmers • 1 Installer level account • 32 User (User) and User (Administrator) level accountsSVM Total Recording Time64
SMDR Call Storage1,000 calls (Without SD card)/40,000 calls (With SD card)Number of Channel for SVMApprox. 20 minutes
Charge Record for Hotel1,000 calls (Without SD card)/10,000 calls (With SD card)Hospitality Billing items for guest rooms and Charge125 messages
Special Carrier Access Code16 digits, 20 entriesManage-ment Features120 minutes
Tenant8Hotel Operator2 ch
Time Service Holiday24Charge Rate4
Verification Code4 digits, 1,000 entriesCharge Denomination7 digits including a decimal
Verification Code Personal Identification Number (PIN)10 digits, 1,000 entriesTIE Line Routing and Modification Table3 currency characters/symbols
Emergency Call32 digits, 10 entriesLeading Number32 entries
Hot Line32 digitsNetworking PBX Code3 digits
Key Pad Protocol Dial (ISDN Service Access)32 digits, 100 entries/extn.NDSS: Monitored PBXs7 digits
Personal Speed Dialling8 digits, 4,000 entriesNDSS: Registered Extensions for Monitor PBX8
Quick Dialling32 digitsMailboxes*1250
Redial32 digits, 1,000 entries/tenantTotal Recording Time500 subscriber mailboxes 1 System Manager mailbox 1 Message Manager mailbox
System Speed Dialling32 digits, 5,000 entries/systemMaximum Message Length40h/200h/400h (SD XS/S/M)
One-touch Dialling-PT32 digits, 1,000 entries/systemNumber of Channel for UM1-60 min (programmable)
One-touch Dialling-PSMessaging Length of Personal GreetingUnlimited for two-way recording
Conference Group8 (31 members/group for Conference Group Mode, 32 members/group for Broadcast Mode)Unified Messaging Ports24 ch
User Group32Users (User)64 entries
Call Pickup Group64 (16 extensions/group)Maintenance Users (Administrator)492 accounts
Idle Extension Hunting Group128 (128 extensions/group)Console Installer8 accounts
Incoming Call Distribution Group32Accounts1 account
Paging Group32Password (all account types)4-16 characters
PS Ring Group64ACD Report Number of Call log for ACD report300,000*2
Trunk Group1
UM Group2 units x 12 ports (24 channels)
VM (DPT) Group2 groups x 32 channels
VM (DTMF) Group32
P2P Group7
TRS/Barring Level16 digits, 100 entries/level
TRS/Barring TRS/Barring Denied Code16 digits, 100 entries/level
TRS/Barring Exception Code

*1 The maximum number of recordings that can be stored in each type of mailbox is 9,000.

*2 Basis of the number 5,000 (calls per day): Ex. 25 (agent) x 20 (call/hour-agent) x 10 (hour/day)

A maximum of 12 months of ACD reports are saved and the exceeded data is deleted automatically.

For the latest information, please refer to the manual.

Some operations may vary depending on the type of telephone or Activation Key being used. Please consult a Panasonic sales company for details.

Design and specifications are subject to change without notice.

PDF preview unavailable. Download the PDF instead.

KX-NS300 Specsheet7 Adobe PDF Library 10.0.1

Related Documents

Preview Panasonic KX-TDA15 Hybrid IP-PBX User Manual
User manual for the Panasonic KX-TDA15 Hybrid IP-PBX system, detailing features, operations, settings, and troubleshooting for efficient use of the PBX.
Preview Panasonic KX-TDE100/200 Converged IP-PBX System: Features, Specifications, and Solutions
Explore the Panasonic KX-TDE100/200 Converged IP-PBX system, a powerful and versatile communication solution for businesses. Discover features, IP telephones, wireless phones, networking, call center capabilities, CTI solutions, system specifications, and maintenance information.
Preview Panasonic Hybrid IP-PBX User Manual: KX-TDA30, KX-TDA100, KX-TDA200
Comprehensive user manual for Panasonic Hybrid IP-PBX systems (KX-TDA30, KX-TDA100, KX-TDA200). Covers operation, features like Call Centre, Voice Mail, PC Console, and system customization for businesses.
Preview Panasonic KX-TDA50 Hybrid IP-PBX User Manual
User manual for the Panasonic KX-TDA50 Hybrid IP-PBX system, providing detailed instructions, feature explanations, safety guidelines, and troubleshooting information for optimal operation.
Preview Panasonic KX-TA824 Advanced Hybrid System Operating Manual
Comprehensive operating manual for the Panasonic KX-TA824 Advanced Hybrid System, detailing features, operations, and important safety information for users.
Preview Panasonic Hybrid IP-PBX KX-TDA100/KX-TDA200 Getting Started Guide
This guide provides essential information for installing, configuring, and starting up the Panasonic Hybrid IP-PBX systems, models KX-TDA100 and KX-TDA200. Learn about initial setup, component installation, and basic operations.
Preview Panasonic KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TG3711SX/KX-TG3712SX/KX-TG3811BX/KX-TG3811JX/KX-TG3811SX/KX-TG3721BX/KX-TG3722BX/KX-TG3721SX/KX-TG3722SX/KX-TG3821BX/KX-TG3821JX/KX-TG3822JX/KX-TG3821SX Operating Instructions
Comprehensive operating instructions for Panasonic 2.4 GHz Digital Cordless Phones and Answering Systems, including models KX-TG3711, KX-TG3712, KX-TG3719, KX-TG3721, KX-TG3722, KX-TG3811, KX-TG3821, and KX-TG3822 series. Covers setup, features, safety information, and specifications.
Preview Panasonic KX-TGC210 Series Digital Cordless Phone Service Manual
This service manual provides detailed information for the Panasonic KX-TGC210 series digital cordless phones, including model numbers KX-TGC210S, KX-TGC212S, KX-TGC213S, KX-TGC220S, KX-TGC222S, KX-TG403SKS, KX-TG433SKS, KX-TGCA20S, KX-TGCA21S, KX-TGDA20N, KX-WP110B, KX-WP120B, and KX-WPA20B. It covers safety precautions, specifications, installation, operation, schematic diagrams, and replacement parts.